Accurate measurement of peripheral blood mononuclear cell concentration using image cytometry to eliminate RBC-induced counting error

被引:25
作者
Chan, Leo Li-Ying [1 ]
Laverty, Daniel J. [1 ]
Smith, Tim [1 ]
Nejad, Parham [2 ]
Hei, Hillary [2 ]
Gandhi, Roopali [2 ]
Kuksin, Dmitry [1 ]
Qiu, Jean [1 ]
机构
[1] Nexcelom Biosci LLC, Dept Technol R&D, Lawrence, MA 01843 USA
[2] Harvard Univ, Brigham & Womens Hosp, Dept Neurol, Sch Med, Boston, MA 02115 USA
关键词
Peripheral blood mononuclear cell (PBMC); Red blood cell (RBC) contamination; Image cytometry; Cellometer Vision; Acridine orange; Propidium iodide; FLOW-CYTOMETRY; VIRUS; VIABILITY; APOPTOSIS;
D O I
10.1016/j.jim.2012.11.010
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Peripheral blood mononuclear cells (PBMCs) have been widely researched in the fields of immunology, infectious disease, oncology, transplantation, hematological malignancy, and vaccine development. Specifically, in immunology research, PBMCs have been utilized to monitor concentration, viability, proliferation, and cytokine production from immune cells, which are critical for both clinical trials and biomedical research. The viability and concentration of isolated PBMCs are traditionally measured by manual counting with trypan blue (TB) using a hemacytometer. One of the common issues of PBMC isolation is red blood cell (RBC) contamination. The RBC contamination can be dependent on the donor sample and/or technical skill level of the operator. RBC contamination in a PBMC sample can introduce error to the measured concentration, which can pass down to future experimental assays performed on these cells. To resolve this issue, RBC lysing protocol can be used to eliminate potential error caused by RBC contamination. In the recent years, a rapid fluorescence-based image cytometry system has been utilized for bright-field and fluorescence imaging analysis of cellular characteristics (Nexcelom Bioscience LLC, Lawrence, MA). The Cellometer image cytometry system has demonstrated the capability of automated concentration and viability detection in disposable counting chambers of unpurified mouse splenocytes and PBMCs stained with acridine orange (AO) and propidium iodide (PI) under fluorescence detection. In this work, we demonstrate the ability of Cellometer image cytometry system to accurately measure PBMC concentration, despite RBC contamination, by comparison of five different total PBMC counting methods: (1) manual counting of trypan blue-stained PBMCs in hemacytometer, (2) manual counting of PBMCs in bright-field images, (3) manual counting of acetic acid lysing of RBCs with TB-stained PBMCs, (4) automated counting of acetic acid lysing of RBCs with PI-stained PBMCs, and (5) AO/PI dual staining method. The results show comparable total PBMC counting among all five methods, which validate the AO/PI staining method for PBMC measurement in the image cytometry method. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:25 / 32
页数:8
相关论文
共 32 条
  • [1] Automation of the ELISpot assay for high-throughput detection of antigen-specific T-cell responses
    Almeida, Coral-Ann M.
    Roberts, Steven G.
    Laird, Rebecca
    McKinnon, Elizabeth
    Ahmed, Imran
    Pfafferott, Katja
    Turley, Joanne
    Keane, Niamh M.
    Lucas, Andrew
    Rushton, Ben
    Chopra, Abha
    Mallal, Simon
    John, Mina
    [J]. JOURNAL OF IMMUNOLOGICAL METHODS, 2009, 344 (01) : 1 - 5
  • [2] Impact of three different types of exercise on components of the inflammatory response
    Brenner, IKM
    Natale, VM
    Vasiliou, P
    Moldoveanu, AI
    Shek, PN
    Shephard, RJ
    [J]. EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1999, 80 (05) : 452 - 460
  • [3] Vaccine-elicited SIV and HIV envelope-specific IgA and IgG memory B cells in rhesus macaque peripheral blood correlate with functional antibody responses and reduced viremia
    Brocca-Cofano, Egidio
    McKinnon, Katherine
    Demberg, Thorsten
    Venzon, David
    Hidajat, Rachmat
    Xiao, Peng
    Daltabuit-Test, Mara
    Patterson, L. Jean
    Robert-Guroff, Marjorie
    [J]. VACCINE, 2011, 29 (17) : 3310 - 3319
  • [4] Rapid Image-based Cytometry for Comparison of Fluorescent Viability Staining Methods
    Chan, Leo L.
    Wilkinson, Alisha R.
    Paradis, Benjamin D.
    Lai, Ning
    [J]. JOURNAL OF FLUORESCENCE, 2012, 22 (05) : 1301 - 1311
  • [5] A novel method for kinetic measurements of rare cell proliferation using Cellometer image-based cytometry
    Chan, Leo L.
    Zhong, Xuemei
    Pirani, Alnoor
    Lin, Bo
    [J]. JOURNAL OF IMMUNOLOGICAL METHODS, 2012, 377 (1-2) : 8 - 14
  • [6] Cellometer Vision as an Alternative to Flow Cytometry for Cell Cycle Analysis, Mitochondrial Potential, and Immunophenotyping
    Chan, Leo L.
    Zhong, Xuemei
    Qiu, Jean
    Li, Peter Y.
    Lin, Bo
    [J]. CYTOMETRY PART A, 2011, 79A (07) : 507 - 517
  • [7] A novel image-based cytometry method for autophagy detection in living cells
    Chan, Leo Li-Ying
    Shen, Dee
    Wilkinson, Alisha R.
    Patton, Wayne
    Lai, Ning
    Chan, Eric
    Kuksin, Dmitry
    Lin, Bo
    Qiu, Jean
    [J]. AUTOPHAGY, 2012, 8 (09) : 1371 - 1382
  • [8] A rapid detection method for apoptosis and necrosis measurement using the Cellometer imaging cytometry
    Chan, Leo Li-Ying
    Lai, Ning
    Wang, Elena
    Smith, Tim
    Yang, Xifeng
    Lin, Bo
    [J]. APOPTOSIS, 2011, 16 (12) : 1295 - 1303
  • [9] Nucleated RBCs - Significance in the peripheral blood film
    Constantino, BT
    Cogionis, B
    [J]. LABORATORY MEDICINE, 2000, 31 (04) : 223 - 229
  • [10] Preliminary report: Evaluation of storage conditions and cryococktails during peripheral blood mononuclear cell cryopreservation
    Cosentino, L. M.
    Corwin, W.
    Baust, J. M.
    Diaz-Mayoral, N.
    Cooley, H.
    Shao, W.
    Van Buskirk, R.
    Baust, J. G.
    [J]. CELL PRESERVATION TECHNOLOGY, 2007, 5 (04): : 189 - 204