Fully Integrated Artificial Pancreas in Type 1 Diabetes: Modular Closed-Loop Glucose Control Maintains Near Normoglycemia

被引:197
|
作者
Breton, Marc [1 ]
Farret, Anne [2 ,3 ]
Bruttomesso, Daniela [4 ]
Anderson, Stacey [1 ]
Magni, Lalo [5 ]
Patek, Stephen [1 ]
Man, Chiara Dalla [6 ]
Place, Jerome [2 ,3 ]
Demartini, Susan [1 ]
Del Favero, Simone [6 ]
Toffanin, Chiara [5 ]
Hughes-Karvetski, Colleen [1 ]
Dassau, Eyal [7 ,8 ]
Zisser, Howard [7 ,8 ]
Doyle, Francis J., III [7 ]
De Nicolao, Giuseppe [5 ]
Avogaro, Angelo [4 ]
Cobelli, Claudio [6 ]
Renard, Eric [2 ,3 ]
Kovatchev, Boris [1 ]
机构
[1] Univ Virginia, Ctr Diabet Technol, Charlottesville, VA 22903 USA
[2] Univ Montpellier, Univ Hosp Montpellier, Dept Endocrinol Diabet & Nutr, INSERM,Clin Invest Ctr 1001, F-34059 Montpellier, France
[3] Univ Montpellier, Inst Funct Genom, CNRS, INSERM,U661,UMR5203, F-34059 Montpellier, France
[4] Univ Padua, Dept Internal Med, Unit Metab Dis, I-35100 Padua, Italy
[5] Univ Pavia, Dept Comp Engn & Syst Sci, I-27100 Pavia, Italy
[6] Univ Padua, Dept Informat Engn, Padua, Italy
[7] Univ Calif Santa Barbara, Santa Barbara, CA 93106 USA
[8] Sansum Diabet Res Inst, Santa Barbara, CA USA
关键词
INSULIN DELIVERY; INFUSION; ADULTS; SYSTEM; MODEL;
D O I
10.2337/db11-1445
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Integrated closed-loop control (CLC), combining continuous glucose monitoring (CGM) with insulin pump (continuous subcutaneous insulin infusion [CSII]), known as artificial pancreas, can help optimize glycemic control in diabetes. We present a fundamental modular concept for CLC design, illustrated by clinical studies involving 11 adolescents and 27 adults at the Universities of Virginia, Padova, and Montpellier. We tested two modular CLC constructs: standard control to range (sCTR), designed to augment pump plus CGM by preventing extreme glucose excursions; and enhanced control to range (eCTR), designed to truly optimize control within near normoglycemia of 3.9-10 trillion. The CLC system was fully integrated using automated data transfer CGM -> algorithm -> CSII All studies used randomized crossover design comparing CSII versus CLC during identical 22-h hospitalizations including meals, overnight rest, and 30-min exercise. sCTR increased significantly the time in near normoglycemia from 61 to 74%, simultaneously reducing hypoglycemia 2.7-fold. eCTR improved mean blood glucose from 7.73 to 6.68 nunol/L without increasing hypoglycemia, achieved 97% in near normoglycemia and 77% in tight glycemic control, and reduced variability overnight. In conclusion, sCTR and eCTR represent sequential steps toward automated CLC, preventing extremes (sCTR) and further optimizing control (eCTR). This approach inspires compelling new concepts: modular assembly, sequential deployment, testing, and clinical acceptance of custom-built CLC systems tailored to individual patient needs. Diabetes 61:2230-2237, 2012
引用
收藏
页码:2230 / 2237
页数:8
相关论文
共 50 条
  • [31] The Efficacy of Basal Rate and Carbohydrate Ratio Learning Algorithm for Closed-Loop Insulin Delivery (Artificial Pancreas) in Youth with Type 1 Diabetes in a Diabetes Camp
    Palisaitis, Emilie
    El Fathi, Anas
    Von Oettingen, Julia E.
    Krishnamoorthy, Preetha
    Kearney, Robert
    Jacobs, Peter
    Rutkowski, Joanna
    Legault, Laurent
    Haidar, Ahmad
    DIABETES TECHNOLOGY & THERAPEUTICS, 2020, 22 (03) : 185 - 194
  • [32] Artificial neural networks for closed loop control of in silico and ad hoc type 1 diabetes
    Fernandez de Canete, J.
    Gonzalez-Perez, S.
    Ramos-Diaz, J. C.
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2012, 106 (01) : 55 - 66
  • [33] Stochastic Virtual Population of Subjects With Type 1 Diabetes for the Assessment of Closed-Loop Glucose Controllers
    Haidar, Ahmad
    Wilinska, Malgorzata E.
    Graveston, James A.
    Hovorka, Roman
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (12) : 3524 - 3533
  • [34] The Closed-Loop System Improved the Control of a Pregnant Patient with Type 1 Diabetes Mellitus
    Guzman Gomez, Guillermo E.
    Viggiano, Julian A.
    Silva-De las Salas, A.
    Martinez, Veline
    Urbano Bonilla, Maria A.
    CASE REPORTS IN ENDOCRINOLOGY, 2021, 2021
  • [35] Multivariable Adaptive Closed-Loop Control of an Artificial Pancreas Without Meal and Activity Announcement
    Turksoy, Kamuran
    Bayrak, Elif Seyma
    Quinn, Lauretta
    Littlejohn, Elizabeth
    Cinar, Ali
    DIABETES TECHNOLOGY & THERAPEUTICS, 2013, 15 (05) : 386 - 400
  • [36] Closed-loop insulin delivery for treatment of type 1 diabetes
    Elleri, Daniela
    Dunger, David B.
    Hovorka, Roman
    BMC MEDICINE, 2011, 9
  • [37] Closed-loop for type 1 diabetes - an introduction and appraisal for the generalist
    Bally, Lia
    Thabit, Hood
    Hovorka, Roman
    BMC MEDICINE, 2017, 15
  • [38] Closed-loop insulin delivery for treatment of type 1 diabetes
    Daniela Elleri
    David B Dunger
    Roman Hovorka
    BMC Medicine, 9
  • [39] Overnight closed loop insulin delivery (artificial pancreas) in adults with type 1 diabetes: crossover randomised controlled studies
    Hovorka, Roman
    Kumareswaran, Kavita
    Harris, Julie
    Allen, Janet M.
    Elleri, Daniela
    Xing, Dongyuan
    Kollman, Craig
    Nodale, Marianna
    Murphy, Helen R.
    Dunger, David B.
    Amiel, Stephanie A.
    Heller, Simon R.
    Wilinska, Malgorzata E.
    Evans, Mark L.
    BMJ-BRITISH MEDICAL JOURNAL, 2011, 342
  • [40] Glycemic control metrics in a cohort of hospitalized patients with type 1 diabetes using hybrid closed-loop and advanced hybrid closed-loop systems
    Medina, Ana Maria Gomez
    Henao-Carrillo, Diana Cristina
    Yepes, Carlos
    Silva, Julio
    Gomzalez, Javier Alberto Gomez
    Cortes, David
    Robledo, Sofia
    Mejia, Gabriela
    Rondon, Martin
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2023, 204