A Suggestion of Combining a PV MPPT Algorithm Based on Temperature Control with a PV Cooling Based on Temperature Control with a PV Cooling System

被引:0
作者
da Rocha, Nuno M. [1 ]
Coelho, Roberto F. [1 ]
Martins, Denizar Cruz [1 ]
Passos, Julio C. [2 ]
机构
[1] Univ Fed Santa Catarina, Dept Elect Engn, Power Elect Inst, Florianopolis, SC, Brazil
[2] Univ Fed Santa Catarina, Dept Mech Engn, Florianopolis, SC, Brazil
来源
IECON 2014 - 40TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY | 2014年
关键词
MPPT; PV module; temperature control; cooling; electricity; heat removal; PHOTOVOLTAIC SYSTEMS; PERFORMANCE; MODULE;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The photovoltaic (PV) module efficiency conversion is affected by environmental changes, particularly by variations in temperature and radiation. There are several devices and techniques that allow a minimization of those effects and changes, by keeping the efficiency conversion at its highest level. Maximum Power Point Tracking (MPPT) and PV cooling systems can provide this efficiency improvement. In this paper it is proposed an association and combination of those systems, with the intent of achieving an even greater efficiency conversion level and also as a suggestion for future works in this area. A generic model of such system is presented.
引用
收藏
页码:1950 / 1956
页数:7
相关论文
共 28 条
  • [1] Arcidiacono V., 1982, Conference Record of the Sixteenth IEEE Photovoltaic Specialists Conference - 1982, P507
  • [2] Comparative Evaluation of Maximum Power Point Tracking Methods for Photovoltaic Systems
    Azevedo, G. M. S.
    Cavalcanti, M. C.
    Oliveira, K. C.
    Neves, F. A. S.
    Lins, Z. D.
    [J]. JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2009, 131 (03): : 0310061 - 0310068
  • [3] Performance evaluation of a PV (photovoltaic) module by back surface water cooling for hot climatic conditions
    Bahaidarah, H.
    Subhan, Abdul
    Gandhidasan, P.
    Rehman, S.
    [J]. ENERGY, 2013, 59 : 445 - 453
  • [4] Bucciarelli L. L., 1980, COO409472 MIT
  • [5] Application of the three-phase series resonant converter in a dual-stage inverter operating without specific sensor to perform the MPPT
    Casaro, Marcio Mendes
    Martins, Denizar Cruz
    [J]. IECON 2007: 33RD ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, VOLS 1-3, CONFERENCE PROCEEDINGS, 2007, : 1650 - +
  • [6] Coelho R., 2010, 2010 9 IEEEIAS INT C, P1
  • [7] Thermal management systems for Photovoltaics (PV) installations: A critical review
    Du, Dengfeng
    Darkwa, Jo
    Kokogiannakis, Georgios
    [J]. SOLAR ENERGY, 2013, 97 : 238 - 254
  • [8] Duffle J.A., 1991, SOLAR ENG THERMAL PR
  • [9] Comparison of photovoltaic array maximum power point tracking techniques
    Esram, Trishan
    Chapman, Patrick L.
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 2007, 22 (02) : 439 - 449
  • [10] An Analytical Solution for Tracking Photovoltaic Module MPP
    Farivar, Ghias
    Asaei, Behzad
    Mehrnami, Siamak
    [J]. IEEE JOURNAL OF PHOTOVOLTAICS, 2013, 3 (03): : 1053 - 1061