摘要
An 80 mm long polarizing S-bender with a large cross-section of 30 x 100 mm(2) for the instrument MIRA at the FRM II has been simulated, built and tested. The results of the experiment show for the wavelength of 4.4 A a homogenous polarization of more than 98% across the bender cross-section and a high transmission of above 65% of the spin up component of the neutron beam. The bender design has the advantage of delivering the polarized beam in the direction of the incoming beam. (c) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:94 / 97
页数:4
相关论文
共 7 条
[1]   Large scales-long times: Adding high energy resolution to SANS [J].
Brandl, G. ;
Georgii, R. ;
Haeussler, W. ;
Muehlbauer, S. ;
Boeni, P. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 654 (01) :394-398
[2]   NEUTRON POLARIZATION WITH A POLARIZED HE-3 SPIN FILTER [J].
COULTER, KP ;
CHUPP, TE ;
MCDONALD, AB ;
BOWMAN, CD ;
BOWMAN, JD ;
SZYMANSKI, JJ ;
YUAN, V ;
CATES, GD ;
BENTON, DR ;
EARLE, ED .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 288 (2-3) :463-466
[3]   CROSS-SECTIONS OF MATERIALS USED AS NEUTRON MONOCHROMATORS AND FILTERS [J].
FREUND, AK .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 213 (2-3) :495-501
[4]   Turn-key module for neutron scattering with sub-micro-eV resolution [J].
Georgii, R. ;
Brandl, G. ;
Arend, N. ;
Haeussler, W. ;
Tischendorf, A. ;
Pfleiderer, C. ;
Boeni, P. ;
Lal, J. .
APPLIED PHYSICS LETTERS, 2011, 98 (07)
[5]   CASCADE, neutron detectors for highest count rates in combination with ASIC/FPGA based readout electronics [J].
Klein, Martin ;
Schmidt, Christian J. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 628 (01) :9-18
[6]   New solid state polarizing bender for cold neutrons [J].
Stunault, A. ;
Andersen, K. H. ;
Roux, S. ;
Bigault, T. ;
Ben-Saidane, K. ;
Ronnow, H. M. .
PHYSICA B-CONDENSED MATTER, 2006, 385-86 :1152-1154
[7]   McStas 1.7-a new version of the flexible Monte Carlo neutron scattering package [J].
Willendrup, Peter ;
Farhi, Emmanuel ;
Lefmann, Kim .
PHYSICA B-CONDENSED MATTER, 2004, 350 (1-3) :E735-E737