AM1, PM3, and PM5 calculations of the absorption maxima of basic organic dyes

被引:43
|
作者
Matsuura, Azuma [1 ]
Sato, Hiroyuki [1 ]
Sotoyama, Wataru [1 ]
Takahashi, Atsuya [2 ]
Sakurai, Minoru [3 ]
机构
[1] Fujitsu Labs Ltd, Atsugi, Kanagawa 2430197, Japan
[2] Fujitsu Ltd, Mihama Ku, Chiba 2618588, Japan
[3] Tokyo Inst Technol, Ctr Biol Resources & Informat, Midori Ku, Yokohama, Kanagawa 2268501, Japan
来源
JOURNAL OF MOLECULAR STRUCTURE-THEOCHEM | 2008年 / 860卷 / 1-3期
关键词
organic dyes; excitation energy; AM1; PM3; PM5;
D O I
10.1016/j.theochem.2008.03.028
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The absorption maxima, lambda(max), of various organic dyes such as indigo, azobenzene, phenylamine, hydrazone, anthraquinone, naphthoquinone, and malachite green were calculated using the AM1, PM3, and PM5 semiempirical molecular orbital theories with the configuration interaction singles (CIS) and random phase approximation (RPA) approaches. The calculated lambda max were then compared with the values obtained by CNDO/S, INDO/S, ab initio CIS, and time-dependent density functional theory (TD-DFT). We found that the lambda(max) values calculated by AM1, PM3, and PM5 were in good correlation with the observed lambda(max) values. When B3LYP/cc-pVDZ optimized geometries were used, the square of the correlation coefficients between the calculated and observed lambda(max), r(lambda)(2), at the AM1-RPA, PM3-RPA, and PM5-RPA levels were 0.891, 0.897, and 0.927, respectively. In particular, r(lambda)(2) at PM5-RPA//B3LYP/cc-pVDZ was the largest among those obtained from all the other calculations including TD/B3LYP/cc-pVDZ//B3LYP/cc-pVDZ (r(lambda)(2) = 0.827). Accordingly, the standard deviation of the difference between observed and calculated lambda(max) by the linear regression function at PM5-RPA//B3LYP/cc-pVDZ was the smallest. It was therefore concluded that this method was the most promising for the prediction of lambda(max) of various dyes among the computational methods studied here. When AM1 optimized geometries were used, r(lambda)(2) at the AM1-RPA, PM3-RPA, and PM5-RPA levels were 0.822, 0.841, and 0.901, respectively, and they were also comparable to that at. TD/B3LYP/cc-pVDZ//B3LYP/cc-pVDZ. Therefore, although some calibration efforts may be needed for AM1 geometries, PM5-RPA(CIS)//AM1 may be a second candidate available for the prediction of the absorption maxima of dyes, especially in the case of emphasizing computational cost. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:119 / 127
页数:9
相关论文
共 50 条