Light scattering from a diffractive-refractive intraocular lens: a goniometer-based approach for individual zone assessment

被引:10
作者
Labuz, Grzegorz [1 ]
van den Berg, Thomas J. T. P. [2 ]
Auffarth, Gerd U. [1 ]
Khoramnia, Ramin [1 ]
机构
[1] Univ Hosp Heidelberg, David J Apple Ctr Vis Res, Dept Ophthalmol, Heidelberg, Germany
[2] Royal Netherlands Acad Arts & Sci, Netherlands Inst Neurosci, Amsterdam, Netherlands
关键词
EXTENDED-DEPTH; OCULAR STRAYLIGHT; OPTICAL-QUALITY; IMAGE QUALITY; PERFORMANCE; HISTORY; DESIGN;
D O I
10.1364/BOE.474778
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We proposed and tested a method to measure light scattering from the diffractive lens profile in an echelle element featuring 9 zones. Measurements were performed using a goniometer-based setup up to 7.5 degrees. The proportion of scattered light was calculated to derive the loss of light. Material scattering was minimal (similar to 1 deg2/sr); however, each echelle zone acted as a scattering source. A nearly gradual straylight increase was found with the zone number showing peak intensity between 3 degrees and 3.75 degrees. An estimated 6.2% +/- 0.1% was lost due to scattering, which ought to be considered when reporting an IOL's light loss.
引用
收藏
页码:6724 / 6732
页数:9
相关论文
共 28 条
  • [1] Patient-Perceived and Laboratory-Measured Halos Associated with Diffractive Bifocal and Trifocal Intraocular Lenses
    Alba-Bueno, Francisco
    Garzon, Nuria
    Vega, Fidel
    Poyales, Francisco
    Millan, Maria S.
    [J]. CURRENT EYE RESEARCH, 2018, 43 (01) : 35 - 42
  • [2] Straylight in Different Types of Intraocular Lenses
    Arias, Augusto
    Ginis, Harilaos
    Artal, Pablo
    [J]. TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2020, 9 (12): : 1 - 7
  • [3] Breyer DRH, 2017, ASIA-PAC J OPHTHALMO, V6, P339, DOI 10.22608/APO.2017186
  • [4] History and development of the apodized diffractive intraocular lens
    Davison, James A.
    Simpson, Michael J.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (05) : 849 - 858
  • [5] Clinically Relevant Optical Properties of Bifocal, Trifocal, and Extended Depth of Focus Intraocular Lenses
    Gatinel, Damien
    Loicq, Jerome
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2016, 32 (04) : 273 - +
  • [6] Trifocality Achieved Through Polypseudophakia: Optical Quality and Light Loss Compared With a Single Trifocal Intraocular Lens
    Labuz, Grzegorz
    Auffarth, Gerd U.
    Knorz, Michael C.
    Son, Hyeck-Soo
    Yildirim, Timur M.
    Khoramnia, Ramin
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2020, 36 (09) : 570 - 577
  • [7] Labuz G, 2020, AM J OPHTHALMOL, V213, P322, DOI 10.1016/j.ajo.2020.01.021
  • [8] Longitudinal Chromatic Aberration and Polychromatic Image Quality Metrics of Intraocular Lenses
    Labuz, Grzegorz
    Papadatou, Eleni
    Khoramnia, Ramin
    Auffarth, Gerd U.
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2018, 34 (12) : 832 - +
  • [9] Straylight from glistenings in intraocular lenses: In vitro study
    Labuz, Grzegorz
    Reus, Nicolaas J.
    van den Berg, Thomas J. T. P.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2017, 43 (01) : 102 - 108
  • [10] Method for in vitro assessment of straylight from intraocular lenses
    Labuz, Grzegorz
    Vargas-Martin, Fernando
    van den Berg, Thomas J. T. P.
    Lopez-Gil, Norberto
    [J]. BIOMEDICAL OPTICS EXPRESS, 2015, 6 (11): : 4457 - 4464