Circumferential or sectored beam arrangements for stereotactic body radiation therapy (SBRT) of primary lung tumors: Effect on target and normal-,structure dose-volume metrics

被引:2
|
作者
Rosenberg, Mara W. [1 ,2 ]
Kato, Catherine M. [3 ]
Carson, Kelly M. P. [4 ]
Matsunaga, Nathan M. [5 ]
Arao, Robert E. [6 ]
Doss, Emily J. [7 ]
McCracken, Charles L. [8 ]
Meng, Lu Z. [9 ]
Chen, Yiyi [6 ]
Laub, Wolfram U. [8 ,10 ]
Fuss, Martin [8 ,10 ]
Tanyi, James A. [8 ,10 ]
机构
[1] Broad Inst MIT & Harvard, Cambridge, MA USA
[2] Brandeis Univ, Dept Phys, Waltham, MA 02254 USA
[3] Macalester Coll, St Paul, MN 55105 USA
[4] Univ N Carolina, Chapel Hill, NC USA
[5] Santa Clara Univ, Santa Clara, CA 95053 USA
[6] Oregon Hlth & Sci Univ, Dept Publ Hlth & Prevent Med, Portland, OR 97239 USA
[7] Providence St Vincent Med Ctr, Dept Internal Med, Portland, OR USA
[8] Oregon Hlth & Sci Univ, Dept Radiat Med, Portland, OR 97239 USA
[9] Univ Calif Davis, Ctr Comprehens Canc, Dept Radiat Oncol, Sacramento, CA 95817 USA
[10] Oregon State Univ, Dept Nucl Engn & Radiat Hlth Phys, Corvallis, OR 97331 USA
关键词
Intensity-modulated radiotherapy; Intensity-modulated arc therapy; Stereotactic body radiotherapy; Beam configuration; CANCER; RADIOTHERAPY; TOXICITY; DELIVERY; RISK;
D O I
10.1016/j.meddos.2013.05.002
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
To compare 2 beam arrangements, sectored (beam entry over ipsilateral hemithorax) vs circumferential (beam entry over both ipsilateral and contralateral lungs), for static-gantry intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) delivery techniques with respect to target and organs-at-risk (OAR) dose-volume metrics, as well as treatment delivery efficiency. Data from 60 consecutive patients treated using stereotactic body radiation therapy (SBRT) for primary non-small-cell lung cancer (NSCLC) formed the basis of this study. Four treatment plans were generated per data set: 1MRT/VMAT plans using sectored (-s) and circumferential (-c) configurations. The prescribed dose (PD) was 60 Gy in 5 fractions to 95% of the planning target volume (PTV) (maximum PTV dose 150% PD) for a 6-MV photon beam. Plan conformality, Rso (ratio of volume circumscribed by the 50% isodose line and the PTV), and D-2 CM (Dmax at a distance >2 cm beyond the PTV) were evaluated. For lungs, mean doses (mean lung dose [MLD1) and percent V-30/V-20/V(1)o/V-5 Gy were assessed. Spinal cord and esophagus D. and D5/D50 were computed. Chest wall (CW) Dmax and absolute V30/V20/V10/V5 Gy were reported. Sectored SBRT planning resulted in significant decrease in contralateral MLD and Vio/ Vs Gy, as well as contralateral CW Dn,a. and V(1)o/V-5 Gy (all p < 0.001). Nominal reductions of D. and Ds/ Dso for the spinal cord with sectored planning did not reach statistical significance for static-gantry IMRT, although VMAT metrics did show a statistically significant decrease (all p < 0.001). The respective measures for esophageal doses were significantly lower with sectored planning (p < 0.001). Despite comparable dose conformality, irrespective of planning configuration, Rso significantly improved with 1MRT-s/VMAT-c (p < 0.001/p = 0.008), whereas D2 cm significantly improved with VMAT-c (p < 0.001). Plan delivery efficiency improved with sectored technique (p < 0.001); mean monitor unit (MU)/cGy of PD decreased from 5.8 1.9 vs 5.3 - 1.7 (IMRT) and 2.7 0.4 vs 2.4 - 0.3 (VMAT). The sectored configuration achieves unambiguous dosimetric advantages over circumferential arrangement in terms of esophageal, contralateral CW, and contralateral lung sparing, in addition to being more efficient at delivery. (C) 2013 American Association of Medical Dosimetrists.
引用
收藏
页码:407 / 412
页数:6
相关论文
共 15 条
  • [1] Dose-Volume Predictors of Radiation Pneumonitis After Lung Stereotactic Body Radiation Therapy (SBRT): Implications for Practice and Trial Design
    Moiseenko, Vitali
    Grimm, Jimm
    Yorke, Ellen
    Jackson, Andrew
    Yip, Anthony
    Minh-Phuong Huynh-Le
    Mahadevan, Anand
    Forster, Kenneth
    Milano, Michael T.
    Hattangadi-Gluth, Jona
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2020, 12 (10)
  • [2] Dose-Volume Metrics Associated With Radiation Pneumonitis After Stereotactic Body Radiation Therapy for Lung Cancer
    Matsuo, Yukinori
    Shibuya, Keiko
    Nakamura, Mitsuhiro
    Narabayashi, Masaru
    Sakanaka, Katsuyuki
    Ueki, Nami
    Miyagi, Ken
    Norihisa, Yoshiki
    Mizowaki, Takashi
    Nagata, Yasushi
    Hiraoka, Masahiro
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 83 (04): : E545 - E549
  • [3] A DOSE-VOLUME ANALYSIS OF RADIATION PNEUMONITIS IN NON-SMALL CELL LUNG CANCER PATIENTS TREATED WITH STEREOTACTIC BODY RADIATION THERAPY
    Barriger, R. Bryan
    Forquer, Jeffrey A.
    Brabham, Jeffrey G.
    Andolino, David L.
    Shapiro, Ronald H.
    Henderson, Mark A.
    Johnstone, Peter A. S.
    Fakiris, Achilles J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 82 (01): : 457 - 462
  • [4] Differences in the dose-volume metrics with heterogeneity correction status and its influence on local control in stereotactic body radiation therapy for lung cancer
    Ueki, Nami
    Matsuo, Yukinori
    Shibuya, Keiko
    Nakamura, Mitsuhiro
    Narabayashi, Masaru
    Sakanaka, Katsuyuki
    Norihisa, Yoshiki
    Mizowaki, Takashi
    Hiraoka, Masahiro
    JOURNAL OF RADIATION RESEARCH, 2013, 54 (02) : 337 - 343
  • [5] The influence of target and patient characteristics on the volume obtained from cone beam CT in lung stereotactic body radiation therapy
    Liu, Hong-Wei
    Khan, Rao
    D'Ambrosi, Rafael
    Krobutschek, Krista
    Nugent, Zoann
    Lau, Harold
    RADIOTHERAPY AND ONCOLOGY, 2013, 106 (03) : 312 - 316
  • [6] Influence of target dose heterogeneity on dose sparing of normal tissue in peripheral lung tumor stereotactic body radiation therapy
    Wei, Zhigong
    Peng, Xingchen
    Wang, Yan
    Yang, Lianlian
    He, Ling
    Liu, Zheran
    Wang, Jingjing
    Mu, Xiaoli
    Li, Ruidan
    Xiao, Jianghong
    RADIATION ONCOLOGY, 2021, 16 (01)
  • [7] INCORPORATING HETEROGENEITY CORRECTION AND 4DCT IN LUNG STEREOTACTIC BODY RADIATION THERAPY (SBRT): THE EFFECT ON TARGET COVERAGE, ORGAN-AT-RISK DOSES, AND DOSE CONFORMITY
    Franks, Kevin N.
    Purdie, Thomas G.
    Dawson, Laura A.
    Bezjak, Andrea
    Jaffray, David A.
    Bissonnette, Jean-Pierre
    MEDICAL DOSIMETRY, 2010, 35 (02) : 101 - 107
  • [8] Lung Stereotactic Body Radiation Therapy (SBRT) dose gradient and PTV volume: a retrospective multi-center analysis
    David Hoffman
    Irena Dragojević
    Jeremy Hoisak
    David Hoopes
    Ryan Manger
    Radiation Oncology, 14
  • [9] Lung Stereotactic Body Radiation Therapy (SBRT) dose gradient and PTV volume: a retrospective multi-center analysis
    Hoffman, David
    Dragojevic, Irena
    Hoisak, Jeremy
    Hoopes, David
    Manger, Ryan
    RADIATION ONCOLOGY, 2019, 14 (01)
  • [10] Effect of Target Changes on Target Coverage and Dose to the Normal Brain in Fractionated Stereotactic Radiation Therapy for Metastatic Brain Tumors
    Miura, Hideharu
    Kenjo, Masahiro
    Doi, Yoshiko
    Ueda, Taro
    Nakao, Minoru
    Ozawa, Shuichi
    Nagata, Yasushi
    ADVANCES IN RADIATION ONCOLOGY, 2023, 8 (06)