Comparison of radiation doses between cone beam CT and multi detector CT: TLD measurements

被引:35
作者
Kim, Sangroh [2 ]
Yoshizumi, Terry T. [1 ]
Toncheva, Greta [1 ]
Yoo, Sua [3 ]
Yin, Fang-Fang [3 ]
机构
[1] Duke Univ, Dept Radiol, Med Ctr, Durham, NC 27710 USA
[2] Duke Univ, Med Phys Grad Program, Durham, NC 27705 USA
[3] Duke Univ, Dept Radiat Oncol, Med Ctr, Durham, NC 27710 USA
关键词
D O I
10.1093/rpd/ncn305
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In recent years, wide beam computed tomography (CT) technique has become standard in radiation oncology whereas there is little information about radiation dose assessments for the technique. A point dose measurement method was employed to assess the radiation doses of cone beams CT (CBCT) and multi detectors CT (MDCT). The radiation doses of both modalities were measured using thermoluminescence dosemeters (TLDs) in head and body CT phantoms. Four TLD chips were placed at the centre and each peripheral channel to measure the doses. From the measurements, the weighted CT dose index for CBCT (CTDIwCBCT) and volume CT dose index for MDCT (CTDIvolMDCT) were derived. In the results, the CTDIwCBCT was 89.7 +/- 4.0 mGy and the CTDIvolMDCT was 137.0 +/- 7.4 mGy for the head scan. For the body scan, they were 37.9 +/- 1.4 and 74.3 +/- 5.3 mGy, respectively. In conclusion, CTDIwCBCT for the head scan was 35% lower than CTDIvolMDCT, and CTDIwCBCT for the body scan was also 49% lower than CTDIvolMDCT.
引用
收藏
页码:339 / 345
页数:7
相关论文
共 15 条
[11]   A dose comparison study between XVI® and OBI® CBCT systems [J].
Song, William Y. ;
Kamath, Srijit ;
Ozawal, Shuichi ;
Al Ani, Shlomi ;
Chvetsov, Alexei ;
Lhandare, Niranjan ;
Palta, Jatinder R. ;
Liu, Chihray ;
Li, Jonathan G. .
MEDICAL PHYSICS, 2008, 35 (02) :480-486
[12]   Single versus multi-detector row CT: Comparison of radiation doses and dose profiles [J].
Thornton, FJ ;
Paulson, EK ;
Yoshizumi, TT ;
Frush, DP ;
Nelson, RC .
ACADEMIC RADIOLOGY, 2003, 10 (04) :379-385
[13]   A review of dosimetry studies on external-beam radiation treatment with respect to second cancer induction [J].
Xu, X. George ;
Bednarz, Bryan ;
Paganetti, Harald .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (13) :R193-R241
[14]   A quality assurance program for the on-board imager® [J].
Yoo, Sua ;
Kim, Gwe-Ya ;
Hammoud, Rabih ;
Elder, Eric ;
Pawlicki, Todd ;
Guan, Huaiqun ;
Fox, Timothy ;
Luxton, Gary ;
Yin, Fang-Fang ;
Munro, Peter .
MEDICAL PHYSICS, 2006, 33 (11) :4431-4447
[15]   Validation of metal oxide semiconductor field effect transistor technology for organ dose assessment during CT: Comparison with thermoluminescent dosimetry [J].
Yoshizumi, Terry T. ;
Goodman, Philip C. ;
Frush, Donald P. ;
Nguyen, Giao ;
Toncheva, Greta ;
Sarder, Maksudur ;
Barnes, Lottie .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (05) :1332-1336