Comparison between 1.5-and 3-T Magnetic Resonance Acquisitions for Direct Targeting Stereotactic Procedures for Deep Brain Stimulation: A Phantom Study

被引:9
作者
Poulen, Gaetan [1 ,2 ,3 ,4 ,5 ,6 ]
Chan Seng, Emilie [1 ,2 ,3 ,4 ,5 ,6 ]
Menjot De Champfleur, Nicolas [7 ]
Cif, Laura [1 ,2 ,3 ,4 ,5 ,6 ]
Cyprien, Fabienne [1 ,2 ,3 ,4 ,5 ,6 ]
Perez, Jerome [2 ,3 ,4 ,5 ,6 ]
Coubes, Philippe [1 ,2 ,3 ,4 ,5 ,6 ]
机构
[1] CHU Montpellier, Unite Pathol Cerebrales Resistantes, Montpellier, France
[2] CHU Montpellier, Unite Rech Comportements & Mouvements Anormaux, Montpellier, France
[3] Univ Montpellier, Montpellier, France
[4] Inst Genom Fonct, Montpellier, France
[5] CNRS UMR5203, Montpellier, France
[6] INSERM, U661, Montpellier, France
[7] CHU Montpellier, Unite Neuroradiol, Montpellier, France
关键词
Accuracy; Comparative study; MRI-based study; Phantom study; Stereotactic neurosurgery; GLOBUS-PALLIDUS-INTERNUS; SUBTHALAMIC NUCLEUS; ELECTRICAL-STIMULATION; GENERALIZED DYSTONIA; MRI; ACCURACY; LOCALIZATION; ELECTRODES; DISTORTION; FUSION;
D O I
10.1159/000509303
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Introduction:Deep brain stimulation (DBS) is a well-established treatment for movement disorders. High magnetic fields could have an impact on distortion. We evaluated 1.5- and 3-T magnetic resonance imaging (MRI) sequences for accuracy, precision, and trueness of our MRI-guided direct targeting protocol.Methods:Effects of distortion on MR sequences (T1- and T2-weighted sequences) can be evaluated using a dedicated phantom (Elekta). Field strength capabilities were assessed on Siemens Avanto (1.5 T) and Skyra (3 T) scanners. We assessed the precision of our stereotactic MRI-guided procedure.Results:We focused on the risk of error due to a high field strength. Error values on the localizer box were between 0.4 and 0.7 mm at 1.5 T and between 0.6 and 2 mm at 3 T. The most accurate 1.5-T sequence is the 3D FLASH T1-weighted sequence, which had an accuracy value of 0.6 mm. At 3 T, the accuracy value of the isotropic 3D FLASH T1-weighted sequence was 1.6 mm.Conclusion:Given the millimetric size of stereotactic targets and electrodes, lead implantation for neuromodulation therapy needs to be accurate. We demonstrate that 3-T imaging could not be used for stereotaxy in our MRI-guided direct targeting protocol because of a risk of error induced by distortion.
引用
收藏
页码:337 / 344
页数:8
相关论文
共 41 条
[1]   Experience with microelectrode guided subthalamic nucleus deep brain stimulation [J].
Amirnovin, R ;
Williams, ZM ;
Cosgrove, GR ;
Eskandar, EN .
NEUROSURGERY, 2006, 58 (02) :96-102
[2]   Imaging artifacts at 3.OT [J].
Bernstein, Matt A. ;
Huston, John, III ;
Ward, Heidi A. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 24 (04) :735-746
[3]   Accuracy of MRI-guided stereotactic thalamic functional neurosurgery [J].
Bourgeois, G ;
Magnin, M ;
Morel, A ;
Sartoretti, S ;
Huisman, T ;
Tuncdogan, E ;
Meier, D ;
Jeanmonod, D .
NEURORADIOLOGY, 1999, 41 (09) :636-645
[4]   3-Tesla MRI of deep brain stimulation patients: safety assessment of coils and pulse sequences [J].
Boutet, Alexandre ;
Hancu, Ileana ;
Saha, Utpal ;
Crawley, Adrian ;
Xu, David S. ;
Ranjan, Manish ;
Hlasny, Eugen ;
Chen, Robert ;
Foltz, Warren ;
Sammartino, Francesco ;
Coblentz, Ailish ;
Kucharczyk, Walter ;
Lozano, Andres M. .
JOURNAL OF NEUROSURGERY, 2020, 132 (02) :586-594
[5]   Direct visualization of deep brain stimulation targets in Parkinson disease with the use of 7-tesla magnetic resonance imaging Clinical article [J].
Cho, Zang-Hee ;
Min, Hoon-Ki ;
Oh, Se-Hong ;
Han, Jae-Yong ;
Park, Chan-Woong ;
Chi, Je-Geun ;
Kim, Young-Bo ;
Paek, Sun Ha ;
Lozano, Andres M. ;
Lee, Kendall H. .
JOURNAL OF NEUROSURGERY, 2010, 113 (03) :639-647
[6]   Electrical stimulation of the globus pallidus internus in patients with primary generalized dystonia: long-term results [J].
Coubes, P ;
Cif, L ;
El Fertit, H ;
Hemm, S ;
Vayssiere, N ;
Serrat, S ;
Picot, MC ;
Tuffery, S ;
Claustres, M ;
Echenne, B ;
Frerebeau, P .
JOURNAL OF NEUROSURGERY, 2004, 101 (02) :189-194
[7]   Deep brain stimulation for dystonia - Surgical technique [J].
Coubes, P ;
Vayssiere, N ;
El Fertit, H ;
Hemm, S ;
Cif, L ;
Kienlen, J ;
Bonafe, A ;
Frerebeau, P .
STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 2002, 78 (3-4) :183-191
[8]  
Coubes P, 1999, NEUROCHIRURGIE, V45, P139
[9]   Treatment of DYT1-generalised dystonia by stimulation of the internal globus pallidus [J].
Coubes, P ;
Roubertie, A ;
Vayssiere, N ;
Hemm, S ;
Echenne, B .
LANCET, 2000, 355 (9222) :2220-2221
[10]   MRI-guided STN DBS in Parkinson's disease without microelectrode recording: efficacy and safety [J].
Foltynie, T. ;
Zrinzo, L. ;
Martinez-Torres, I. ;
Tripoliti, E. ;
Petersen, E. ;
Holl, E. ;
Aviles-Olmos, I. ;
Jahanshahi, M. ;
Hariz, M. ;
Limousin, P. .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 2011, 82 (04) :358-363