Highly Porous Tantalum Acetabular Components Without Ancillary Screws Have Similar Migration to Porous Titanium Acetabular Components With Screws at 2 Years: A Randomized Controlled Trial

被引:9
作者
Howie, Donald W. [1 ,2 ]
Holubowycz, Oksana T. [2 ]
Callary, Stuart A. [1 ,2 ]
Robertson, Thomas S. [2 ]
Solomon, Lucian B. [1 ,2 ]
机构
[1] Royal Adelaide Hosp, Dept Orthopaed & Trauma, Level 5,1 Port Rd, Adelaide, SA 5000, Australia
[2] Univ Adelaide, Ctr Orthopaed & Trauma Res, Adelaide, SA, Australia
基金
英国医学研究理事会;
关键词
total hip arthroplasty; primary; acetabular component; migration; radiostereometric; TOTAL HIP-ARTHROPLASTY; FOLLOW-UP; RADIOSTEREOMETRIC ANALYSIS; RADIOGRAPHIC EVALUATION; BONE INGROWTH; PRESS-FIT; FIXATION; CUPS; RSA; WEAR;
D O I
10.1016/j.arth.2020.05.049
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: It is proposed that highly porous coatings on acetabular components, such as a porous tantalum coating, provide adequate fixation without ancillary screw fixation in primary total hip arthroplasty (THA). However, tantalum acetabular components have been associated with higher rates of revision than other uncemented components in national registries. The aim of this randomized controlled trial is to determine whether the early migration of a solid-backed tantalum acetabular component was no greater than that of a titanium acetabular component with ancillary screw fixation that has proven good clinical results. Methods: Sixty-six patients aged 40 to 64 years, with osteoarthritis and Charnley grade A or B activity grade and who underwent primary THA, were recruited into the trial. Patients were randomized intraoperatively to receive either the tantalum or titanium acetabular component. All patients received the same cemented polished tapered femoral stem, 28-mm cobalt-chromium femoral head, and highly cross-linked polyethylene liner. Acetabular component migration was measured using radiostereometric analysis at 4-6 days postoperatively and at 6 weeks, 3 months, 1 and 2 years following THA. Results: The mean proximal migration at 2 years for the tantalum cohort was 0.17 mm (95% confidence interval, 0.09-0.24) which was no greater than that of the titanium cohort which was 0.19 mm (0.07-0.32). Harris hip scores and functional activity scores were similar between groups. Conclusion: These results demonstrate that early stability can be achieved without ancillary screw fixation through the use of a highly porous high friction coating on a solid-backed modular acetabular component. Level of Evidence: Level I. (C) 2020 Elsevier Inc. All rights reserved.
引用
收藏
页码:2931 / 2937
页数:7
相关论文
共 30 条
[1]  
[Anonymous], 2018, Hip, knee Shoulder Arthroplasty: 2018 Annual Report
[2]   Radiostereometric Analysis Study of Tantalum Compared with Titanium Acetabular Cups and Highly Cross-Linked Compared with Conventional Liners in Young Patients Undergoing Total Hip Replacement [J].
Ayers, David C. ;
Greene, Meridith ;
Snyder, Benjamin ;
Aubin, Michelle ;
Drew, Jacob ;
Bragdon, Charles .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2015, 97A (08) :627-634
[3]   Comparison of trabecular metal cups and titanium fiber-mesh cups in primary hip arthroplasty A randomized RSA and bone mineral densitometry study of 50 hips [J].
Baad-Hansen, Thomas ;
Kold, Soren ;
Nielsen, Poul Torben ;
Laursen, Mogens Berg ;
Christensen, Poul Hedevang ;
Soballe, Kjeld .
ACTA ORTHOPAEDICA, 2011, 82 (02) :155-160
[4]   Characteristics of bone ingrowth and interface mechanics of a new porous tantalum biomaterial [J].
Bobyn, JD ;
Stackpool, GJ ;
Hacking, SA ;
Tanzer, M ;
Krygier, JJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1999, 81B (05) :907-914
[5]   RSA wear measurements with or without markers in total hip arthroplasty [J].
Börlin, N ;
Röhrl, SM ;
Bragdon, CR .
JOURNAL OF BIOMECHANICS, 2006, 39 (09) :1641-1650
[6]  
DELEE JG, 1976, CLIN ORTHOP RELAT R, P20
[7]   Primary Total Hip Arthroplasty with a Porous-Coated Acetabular Component A Concise Follow-up, at a Minimum of Twenty Years, of Previous Reports [J].
Della Valle, Craig J. ;
Mesko, Nathan W. ;
Quigley, Laura ;
Rosenberg, Aaron G. ;
Jacobs, Joshua J. ;
Galante, Jorge O. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (05) :1130-1135
[8]   Radiographic evaluation of a monoblock acetabular component - A multicenter study with 2-to 5-year results [J].
Gruen, TA ;
Poggie, RA ;
Lewallen, DG ;
Hanssen, AD ;
Lewis, RJ ;
O'Keefe, TJ ;
Stulberg, SD ;
Sutherland, CJ .
JOURNAL OF ARTHROPLASTY, 2005, 20 (03) :369-378
[10]   Survival of 11,390 Continuum cups in primary total hip arthroplasty based on data from the Finnish Arthroplasty Register [J].
Hemmila, Matias ;
Karvonen, Mikko ;
Laaksonen, Inari ;
Matilainen, Markus ;
Eskelinen, Antti ;
Haapakoski, Jaason ;
Puhto, Ari-Pekka ;
Kettunen, Jukka ;
Manninen, Mikko ;
Makela, Keijo T. .
ACTA ORTHOPAEDICA, 2019, 90 (04) :312-317