Paclitaxel-Coated Versus Uncoated Balloon Angioplasty Reduces Target Lesion Revascularization in Patients With Femoropopliteal Arterial Disease A Meta-Analysis of Randomized Trials

被引:110
作者
Cassese, Salvatore [1 ]
Byrne, Robert A. [1 ]
Ott, Ilka [1 ]
Ndrepepa, Gjin [1 ]
Nerad, Mateja [1 ]
Kastrati, Adnan [1 ]
Fusaro, Massimiliano [1 ]
机构
[1] Tech Univ Munich, Deutsch Herzzentrum, D-80636 Munich, Germany
关键词
drug-eluting balloon; meta-analysis; peripheral intervention; restenosis; STENT IMPLANTATION; CLINICAL-TRIALS; ELUTING STENTS; FOLLOW-UP; RESTENOSIS; PREVENTION;
D O I
10.1161/CIRCINTERVENTIONS.112.969972
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-In disease of the femoropopliteal artery, paclitaxel-coated balloon (PCB) therapy improved angiographic outcomes as compared with uncoated balloon (UCB) angioplasty. Nevertheless, it remains uncertain whether PCB may reduce the need for reintervention. Methods and Results-We searched Medline, EMBASE, the Cochrane Central Register of Controlled Trials (CENTRAL), scientific session abstracts, and relevant web sites for trials of PCB versus UCB angioplasty. Key words were: "superficial femoral artery," "popliteal artery," "angioplasty," "drug-eluting balloon," "paclitaxel-eluting balloon," and "randomized trial." Inclusion criteria were: (1) randomized design; (2) intention-to-treat analysis; and (3) >= 6-month follow-up. Exclusion criteria were: (1) vessel treated other than femoropopliteal artery; (2) device used other than PCB/UCB; and (3) irretrievable or duplicated data. No restrictions (language, publication date, or status) were applied. The primary end point was target lesion revascularization. Secondary end points were: angiographic binary restenosis and late lumen loss and all-cause mortality. A total of 381 patients enrolled in 4 randomized trials were included (PCB, n=186 versus UCB, n=195). Median follow-up was 10.3 months. Angioplasty with PCB versus UCB reduces target lesion revascularization (12.2% versus 27.7%; OR, 0.22; 95% CI, 0.13-0.38; P<0.00001), angiographic restenosis (18.7% versus 45.5%; OR, 0.26; 95% CI, 0.14-0.48; P<0.0001), and late lumen loss (range, -0.05 to 0.50 mm versus 0.61-1.7 mm; weighted mean difference, -0.75 mm; 95% CI, -1.06 to -0.45; P<0.00001). No mortality difference was observed for PCB versus UCB (2.1% versus 3.2%; OR, 0.99; 95% CI, 0.39-2.49; P=0.98). Conclusions-In femoropopliteal arterial disease, PCB therapy is associated with superior antirestenotic efficacy as compared with UCB angioplasty with no evidence of a differential safety profile. (Circ Cardiovasc Interv. 2012; 5:582-589.)
引用
收藏
页码:582 / 589
页数:8
相关论文
共 26 条
[1]   Reduction of stenosis due to intimal hyperplasia after stent supported angioplasty of peripheral arteries by local administration of paclitaxel in Swine [J].
Albrecht, Thomas ;
Speck, Ulrich ;
Baier, Claudia ;
Wolf, Karl-Juergen ;
Boehm, Michael ;
Scheller, Bruno .
INVESTIGATIVE RADIOLOGY, 2007, 42 (08) :579-585
[2]  
[Anonymous], CARD INT RAD SOC EUR
[3]  
[Anonymous], TRANSC CARD THER C 2
[4]  
[Anonymous], BMJ
[5]   Paclitaxel-Eluting Stents Show Superiority to Balloon Angioplasty and Bare Metal Stents in Femoropopliteal Disease Twelve-Month Zilver PTX Randomized Study Results [J].
Dake, Michael D. ;
Ansel, Gary M. ;
Jaff, Michael R. ;
Ohki, Takao ;
Saxon, Richard R. ;
Smouse, H. Bob ;
Zeller, Thomas ;
Roubin, Gary S. ;
Burket, Mark W. ;
Khatib, Yazan ;
Snyder, Scott A. ;
Ragheb, Anthony O. ;
White, J. King ;
Machan, Lindsay S. .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2011, 4 (05) :495-504
[6]   Surrogate end points in clinical trials: Are we being misled? [J].
Fleming, TR ;
DeMets, DL .
ANNALS OF INTERNAL MEDICINE, 1996, 125 (07) :605-613
[7]   Vascular Response to Zotarolimus-Coated Balloons in Injured Superficial Femoral Arteries of the Familial Hypercholesterolemic Swine [J].
Granada, Juan F. ;
Milewski, Krzysztof ;
Zhao, Hugh ;
Stankus, John J. ;
Tellez, Armando ;
Aboodi, Michael S. ;
Kaluza, Greg L. ;
Krueger, Christian G. ;
Virmani, Renu ;
Schwartz, Lewis B. ;
Nikanorov, Alexander .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2011, 4 (05) :447-455
[8]   Drug-Coated Balloons for the Prevention of Vascular Restenosis [J].
Gray, William A. ;
Granada, Juan F. .
CIRCULATION, 2010, 121 (24) :2672-2680
[9]   Measuring inconsistency in meta-analyses [J].
Higgins, JPT ;
Thompson, SG ;
Deeks, JJ ;
Altman, DG .
BMJ-BRITISH MEDICAL JOURNAL, 2003, 327 (7414) :557-560
[10]   The hazards of scoring the quality of clinical trials for meta-analysis [J].
Jüni, P ;
Witschi, A ;
Bloch, R ;
Egger, M .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1999, 282 (11) :1054-1060