Auto bi-level pressure relief-PAP is as effective as CPAP in OSA patients-a pilot study

被引:23
作者
Blau, Alexander [1 ]
Minx, Mihaela [1 ]
Peter, Jan Giso [1 ]
Glos, Martin [1 ]
Penzel, Thomas [1 ]
Baumann, Gert [1 ]
Fietze, Ingo [1 ]
机构
[1] Charite, CCM, Ctr Sleep Med, D-10117 Berlin, Germany
关键词
Sleep apnea; Continuous positive airway pressure; CPAP; Bi-level PAP; Pressure relief; POSITIVE AIRWAY PRESSURE; OBSTRUCTIVE SLEEP-APNEA; NASAL CPAP; EFFICACY; TRIAL;
D O I
10.1007/s11325-011-0574-1
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Continuous positive airway pressure (CPAP) is the therapy of choice for the treatment of obstructive sleep apnea (OSA). Not all patients can use CPAP therapy with adequate compliance. There is a need to develop more comfortable modes. Auto bi-level Pressure Relief-Positive Airway Pressure (ABPR-PAP) can be an alternative. We conducted a prospective double-blind, randomised trial to evaluate the efficacy and compliance of ABPR-PAP compared with CPAP in OSA patients. We included 35 CPAP naive patients (age 53.3 +/- 10.3 years, BMI 31.0 +/- 5.0 kg/m(2), ESS 10.0 +/- 4.2) diagnosed with moderate to severe OSA who underwent a successful CPAP titration. Patients were randomised into the CPAP or the ABPR-PAP treatment group. We used the same device (BIPAPA (R) Auto, Philips Respironics) for CPAP or ABPR-PAP. Apnea-hypopnea index (AHI) was determined using polysomnography before (AHI 40.6 A +/- 18.3 per hour) and after treatment. Eighteen patients received CPAP and the remaining 17 received APBR-PAP. Groups were similar in terms of demographics and OSA severity. There were no serious adverse events during the trial. CPAP was fixed by a sleep expert and ABPR-PAP varied (range 5-15 cmH(2)O). AHI decreased in the CPAP group to 6.4 +/- 5.7 per hour and in the ABPR-PAP group to 4.8 +/- 3.6 per hour in the first night (N = 35). After 3 months, the AHI decreased in the CPAP group to 4.4 +/- 5.3 per hour and in the ABPR-PAP group to 2.6 +/- 3.8 per hour (N = 32). Differences between the groups were not statistically significant. There were no differences in compliance. ABPR-PAP is a promising new ventilation mode that enables effective treatment of OSA patients.
引用
收藏
页码:773 / 779
页数:7
相关论文
共 24 条
[1]   Bench testing of auto-adjusting positive airway pressure devices [J].
Abdenbi, F ;
Chambille, B ;
Escourrou, P .
EUROPEAN RESPIRATORY JOURNAL, 2004, 24 (04) :649-658
[2]  
Aloia Mark S, 2007, Behav Sleep Med, V5, P229
[3]   Treatment adherence and outcomes in flexible vs standard continuous positive airway pressure therapy [J].
Aloia, MS ;
Stanchina, M ;
Arnedt, JT ;
Malhotra, A ;
Millman, RP .
CHEST, 2005, 127 (06) :2085-2093
[4]   Auto-titrating versus standard continuous positive airway pressure for the treatment of obstructive sleep apnea: Results of a meta-analysis [J].
Ayas, NT ;
Patel, SR ;
Malhotra, A ;
Schulzer, M ;
Malhotra, M ;
Jung, D ;
Fleetham, J ;
White, DP .
SLEEP, 2004, 27 (02) :249-253
[5]   Randomized Controlled Trial Comparing Flexible and Continuous Positive Airway Pressure Delivery: Effects on Compliance, Objective and Subjective Sleepiness and Vigilance [J].
Bakker, Jessie ;
Campbell, Angela ;
Neill, Alister .
SLEEP, 2010, 33 (04) :523-529
[6]  
BONNET MH, 1992, SLEEP, V15, P526
[7]   THE PITTSBURGH SLEEP QUALITY INDEX - A NEW INSTRUMENT FOR PSYCHIATRIC PRACTICE AND RESEARCH [J].
BUYSSE, DJ ;
REYNOLDS, CF ;
MONK, TH ;
BERMAN, SR ;
KUPFER, DJ .
PSYCHIATRY RESEARCH, 1989, 28 (02) :193-213
[8]   Mortality in obstructive sleep apnea-hypopnea patients treated with positive airway pressure [J].
Campos-Rodriguez, F ;
Peña-Griñan, N ;
Reyes-Nuñez, N ;
De la Cruz-Moron, I ;
Perez-Ronchel, J ;
De la Vega-Gallardo, F ;
Fernandez-Palacin, A .
CHEST, 2005, 128 (02) :624-633
[9]   Interrater reliability between scorers from eight European sleep laboratories in subjects with different sleep disorders [J].
Danker-Hopfe, H ;
Kunz, D ;
Gruber, G ;
Klösch, G ;
Lorenzo, JL ;
Himanen, SL ;
Kemp, B ;
Penzel, T ;
Röschke, J ;
Dorn, H ;
Schlögl, A ;
Trenker, E ;
Dorffner, G .
JOURNAL OF SLEEP RESEARCH, 2004, 13 (01) :63-69
[10]   Bi-level positive pressure ventilation and adaptive servo ventilation in patients with heart failure and Cheyne-Stokes respiration [J].
Fietze, Ingo ;
Blau, Alexander ;
Glos, Martin ;
Theres, Heinz ;
Baumann, Gert ;
Penzel, Thomas .
SLEEP MEDICINE, 2008, 9 (06) :652-659