Imaging Features of Postoperative Complications After Spinal Surgery and Instrumentation

被引:36
作者
Hayashi, Daichi [1 ]
Roemer, Frank W. [1 ,2 ]
Mian, Asim [1 ]
Gharaibeh, Monther [1 ]
Mueller, Bernhard [3 ]
Guermazi, Ali [1 ]
机构
[1] Boston Univ, Sch Med, Dept Radiol, Boston, MA 02118 USA
[2] Klinikum Augsburg, Dept Radiol, Augsburg, Germany
[3] Klinikum Traunstein, Dept Orthopaed Surg, Traunstein, Germany
关键词
complications; hardware; imaging; spine; PEDICLE SCREW FIXATION;
D O I
10.2214/AJR.11.6497
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this article is to illustrate common postoperative complications and their imaging appearances after spinal surgery, including stabilization, fusion, and disk replacement with various techniques and devices. CONCLUSION. Radiography is the primary modality for routine follow-up, but MDCT has become the standard for optimized assessment of postoperative implants, and MRI plays a major role in the diagnosis of complications such as infection and soft-tissue lesions.
引用
收藏
页码:W123 / W129
页数:7
相关论文
共 16 条
[1]   Complications of pedicle screw fixation in reconstructive surgery of the cervical spine [J].
Abumi, K ;
Shono, Y ;
Ito, M ;
Taneichi, H ;
Kotani, Y ;
Kaneda, K .
SPINE, 2000, 25 (08) :962-969
[2]   FRACTURES OF THE ODONTOID PROCESS - TREATMENT WITH ANTERIOR SCREW FIXATION [J].
AEBI, M ;
ETTER, C ;
COSCIA, M .
SPINE, 1989, 14 (10) :1065-1070
[3]  
CAUTHEN JC, 2003, SPINE J, V3, P117
[4]  
Cauthen Joseph C, 2003, Spine J, V3, P106, DOI 10.1016/S1529-9430(02)00533-8
[5]   Multichannel CT: Evaluating the spine in postoperative patients with orthopedic hardware [J].
Douglas-Akinwande, Annette C. ;
Buckwalter, Kenneth A. ;
Rydberg, Jonas ;
Rankin, James L. ;
Choplin, Robert H. .
RADIOGRAPHICS, 2006, 26 :S97-U107
[6]   A biomechanical comparison of facet screw fixation and pedicle screw fixation - Effects of short-term and long-term repetitive cycling [J].
Ferrara, LA ;
Secor, JL ;
Jin, BH ;
Wakefield, A ;
Inceoglu, S ;
Benzel, EC .
SPINE, 2003, 28 (12) :1226-1234
[7]   The use of pedicle-screw internal fixation for the operative treatment of spinal disorders [J].
Gaines, RW .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (10) :1458-1476
[8]   Can a modified interspinous spacer prevent instability in axial rotation and lateral bending? A biomechanical in vitro study resulting in a new idea [J].
Kettler, A. ;
Drumm, J. ;
Heuer, F. ;
Haeussler, K. ;
Mack, C. ;
Claes, L. ;
Wilke, H. -J. .
CLINICAL BIOMECHANICS, 2008, 23 (02) :242-247
[9]   Correlative radiological, self-assessment and clinical analysis of evolution instrumented dorsal and lateral fusion for degenerative lumbar spine disease. Autograft versus coralline hydroxyapatite [J].
Korovessis, P ;
Koureas, G ;
Zacharatos, S ;
Papazisis, Z ;
Lambiris, E .
EUROPEAN SPINE JOURNAL, 2005, 14 (07) :630-638
[10]  
McAfee Paul C, 2004, Spine J, V4, p177S, DOI 10.1016/j.spinee.2004.07.003