Are conventional reconstruction plates equivalent to precontoured locking plates for distal humerus fracture fixation? A biomechanics cadaver study

被引:30
|
作者
Koonce, Ryan C. [1 ]
Baldini, Todd H. [2 ]
Morgan, Steven J. [3 ]
机构
[1] Skagit Reg Clin, Mt Vernon, WA 98274 USA
[2] Univ Colorado, Sch Med, Dept Orthopaed Surg, Aurora, CO 80045 USA
[3] Swedish Med Ctr, MOTUS Orthopaed, Englewood, CO 80113 USA
关键词
Humerus fracture; Fixation; Locking plate; Biomechanics; Cadaver; PLATING SYSTEMS; PARALLEL;
D O I
10.1016/j.clinbiomech.2012.03.008
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: The optimal plate type and configuration for distal humerus fracture fixation has yet to be defined. Available biomechanical studies show conflicting results. No existing studies compare conventional reconstruction plates to newer precontoured distal humerus locking plates in both parallel and perpendicular configurations. Methods: Three groups of humerus specimens were compared via biomechanical testing in a cadaver model simulating metaphyseal comminution. Group 1 consisted of conventional reconstruction plates in a perpendicular configuration. Group 2 used precontoured locking plates in a perpendicular configuration. Group 3 used precontoured locking plates in a parallel configuration. Each group was tested for stiffness in anterior bending, posterior bending, axial compression, and torsion. The specimens then underwent cyclic loading followed by single load to failure in posterior bending. Findings: There was no significant difference between the three groups for anterior bending, posterior bending, axial compression, or torsional stiffness. There was no significant difference in load to failure for any of the three groups. Screw loosening was significantly higher in Group 1 when compared to Groups 2 and 3 after cyclic loading. Interpretation: In the early postoperative period, less expensive perpendicular conventional reconstruction plate constructs provide similar stiffness and load to failure properties to newer precontoured locking plate systems regardless of plate configuration. (c) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:697 / 701
页数:5
相关论文
共 50 条
  • [21] Biomechanical Testing of Additive Manufactured Proximal Humerus Fracture Fixation Plates
    Maryam Tilton
    April Armstrong
    Jennifer Sanville
    Matthew Chin
    Michael W. Hast
    Gregory S. Lewis
    Guha P. Manogharan
    Annals of Biomedical Engineering, 2020, 48 : 463 - 476
  • [22] Fixation of Transverse Acetabular Fractures With Precontoured Plates Alone Causes Fracture Malreduction: A Biomechanical Assessment
    Alfonso, Nicholas A.
    Ryan, Weston
    Baldini, Todd
    Reiter, Michael
    Joyce, Christopher
    Mauffrey, Cyril
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2020, 34 (02) : 89 - 94
  • [23] Distal radius fracture fixation with volar locking plates and additional bone augmentation in osteoporotic bone: a biomechanical study in a cadaveric model
    F. Högel
    S. Mair
    S. Eberle
    P. Weninger
    G. von Oldenburg
    P. Augat
    Archives of Orthopaedic and Trauma Surgery, 2013, 133 : 51 - 57
  • [24] Distal radius fracture fixation with volar locking plates and additional bone augmentation in osteoporotic bone: a biomechanical study in a cadaveric model
    Hoegel, F.
    Mair, S.
    Eberle, S.
    Weninger, P.
    von Oldenburg, G.
    Augat, P.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2013, 133 (01) : 51 - 57
  • [25] CAD-CAM plates versus conventional fixation plates for primary mandibular reconstruction: A biomechanical in vitro analysis
    Rendenbach, Carsten
    Sellenschloh, Kay
    Gerbig, Lucca
    Morlock, Michael M.
    Beck-Broichsitter, Benedicta
    Smeets, Ralf
    Heiland, Max
    Huber, Gerd
    Hanken, Henning
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2017, 45 (11) : 1878 - 1883
  • [26] Biomechanical study of olecranon plate fixation in comminuted osteoporotic fracture model: locking compression plates versus dynamic compression plates
    Shakir, Irshad
    Israel, Heidi
    Cannada, Lisa K.
    Bledsoe, Gary
    CURRENT ORTHOPAEDIC PRACTICE, 2018, 29 (02): : 167 - 172
  • [27] PEEK versus titanium locking plates for proximal humerus fracture fixation: a comparative biomechanical study in two- and three-part fractures
    Benedikt Schliemann
    Robert Seifert
    Christina Theisen
    Dominic Gehweiler
    Dirk Wähnert
    Martin Schulze
    Michael J. Raschke
    Andre Weimann
    Archives of Orthopaedic and Trauma Surgery, 2017, 137 : 63 - 71
  • [28] PEEK versus titanium locking plates for proximal humerus fracture fixation: a comparative biomechanical study in two- and three-part fractures
    Schliemann, Benedikt
    Seifert, Robert
    Theisen, Christina
    Gehweiler, Dominic
    Wahnert, Dirk
    Schulze, Martin
    Raschke, Michael J.
    Weimann, Andre
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2017, 137 (01) : 63 - 71
  • [29] Comparison of different distal radius dorsal and volar fracture fixation plates: A biomechanical study
    Osada, D
    Viegas, SF
    Shah, MA
    Morris, RP
    Patterson, RM
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2003, 28A (01): : 94 - 104
  • [30] One size may not fit all: patient-specific computational optimization of locking plates for improved proximal humerus fracture fixation
    Schader, Jana Felicitas
    Mischler, Dominic
    Dauwe, Jan
    Richards, R. Geoff
    Gueorguiev, Boyko
    Varga, Peter
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2022, 31 (01) : 192 - 200