In-Line Mach-Zehnder Interferometric Sensor Based on a Seven-Core Optical Fiber

被引:61
|
作者
Wang, Xiaoliang [1 ,2 ]
Chen, Daru [1 ,2 ]
Li, Haitao [1 ,2 ]
Feng, Gaofeng [3 ]
Yang, Junyong [3 ]
机构
[1] Zhejiang Normal Univ, Inst Informat Opt, Jinhua 321004, Peoples R China
[2] Zhejiang Normal Univ, Hangzhou Inst Adv Studies, Hangzhou 311200, Zhejiang, Peoples R China
[3] Futong Grp Co Ltd, Fuyang 311400, Peoples R China
基金
国家高技术研究发展计划(863计划);
关键词
Optical fiber sensor; Mach-Zehnder interferometer; seven-core fiber; CURVATURE;
D O I
10.1109/JSEN.2016.2613018
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An in-line Mach-Zehnder interferometer (MZI) is proposed and experimentally demonstrated. The sensor is fabricated by splicing a segment of seven-core fiber (SCF) and two segments of very short multi-mode fibers (MMFs). The mode field of the MMF used in our experiments close to the region of hexagonally distributed fiber cores of the SCF, which help to obtain a higher coupling efficiency. A clear interference spectrum of the proposed MZI is obtained by injecting a broadband light into a lead-in single-mode fiber. Such an MZI could be used to realize the measurement of temperature and curvature. The temperature and curvature sensitivities are 55.81 pm/degrees C and 31.54 nm/m(-1), respectively.
引用
收藏
页码:100 / 104
页数:5
相关论文
共 50 条
  • [1] In-Line Mach-Zehnder Interferometric Sensor Based on a Linear Five-Core Fiber
    Guan, Chunying
    Zhong, Xing
    Mao, Guopei
    Yuan, Tingting
    Yang, Jing
    Yuan, Libo
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2015, 27 (06) : 635 - 638
  • [2] Wearable respiratory sensor based on Mach-Zehnder interferometer in seven-core fiber
    Shao, Min
    Yuan, Yubo
    Zhang, Yan
    Cao, Zhongwei
    Li, Fei
    Qiao, Xueguang
    OPTICS AND LASER TECHNOLOGY, 2024, 174
  • [3] In-Line Abrupt Taper Optical Fiber Mach-Zehnder Interferometric Strain Sensor
    Tian, Zhaobing
    Yam, Scott S. -H.
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2009, 21 (1-4) : 161 - 163
  • [4] High-sensitivity humidity sensor based on Mach-Zehnder interferometer in seven-core fiber
    Shao, Min
    Yu, Yang
    Ma, Xinyuan
    Fu, Haiwei
    Zhang, Wensong
    Lu, Qingqing
    OPTICS COMMUNICATIONS, 2025, 574
  • [5] Highly sensitive torsion sensor based on Mach-Zehnder interference in helical seven-core fiber taper
    Wang, Jiabin
    Zeng, Xinzhe
    Zhou, Jian
    Hao, Jiayu
    Yang, Xingyu
    Liu, Yue
    Chen, Wenhuan
    Li, Song
    Yan, Yunxiang
    Geng, Tao
    Sun, Weimin
    Yuan, Libo
    CHINESE OPTICS LETTERS, 2023, 21 (04)
  • [6] A High Sensitivity Curvature Sensor Based on Microfiber Mach-Zehnder Interferometer With Tapered Seven-Core Fiber
    Ji, Yancheng
    Sun, Dan
    Chen, Yupei
    Shi, Yuechun
    Cao, Juan
    Zhang, Guoan
    Han, Zhanghua
    Wang, Chinhua
    Zhu, Xiaojun
    IEEE SENSORS JOURNAL, 2021, 21 (21) : 24090 - 24097
  • [7] Simultaneous Measurement of Strain and Torsion based on a seven-core fiber Mach-Zehnder Interferometer
    Zhang, Fan
    Hu, Junhui
    Wei, Jinpeng
    ELEVENTH INTERNATIONAL CONFERENCE ON INFORMATION OPTICS AND PHOTONICS (CIOP 2019), 2019, 11209
  • [8] Twin core photonic crystal fiber for in-line Mach-Zehnder interferometric sensing applications
    Kim, Bongkyun
    Kim, Tae-Hoon
    Cui, Long
    Chung, Youngjoo
    OPTICS EXPRESS, 2009, 17 (18): : 15502 - 15507
  • [9] Optical fiber strain and temperature sensor based on an in-line Mach-Zehnder interferometer using thin-core fiber
    Sun, Miao
    Xu, Ben
    Dong, Xinyong
    Li, Yi
    OPTICS COMMUNICATIONS, 2012, 285 (18) : 3721 - 3725
  • [10] Optical fiber internal mirror based fiber in-line Mach-Zehnder interferometer
    Gong, H.
    Wang, D. N.
    Xu, B.
    Ni, K.
    Liu, H.
    Zhao, C. L.
    SIXTH EUROPEAN WORKSHOP ON OPTICAL FIBRE SENSORS, 2016, 9916