摘要
This paper includes results from a research work carried out for developing and optimising a sensor to measure the limiting current of oxygen reduction in concrete. Platinum, stainless steel and carbon steel materials were tested as working electrodes in saturated Ca(OH)2 solution. Linear correlations were obtained between the limiting currents of oxygen reduction and the oxygen concentration in solution. The measurements of the limiting current density due to oxygen reduction have been made in concrete specimens with a sensor consisting of platinum and stainless steel, as working electrodes, graphite, as a counter electrode, and activated titanium, as a reference electrode, under different conditions of water and oxygen accessibility to the concrete. The results show that this sensor detects oxygen content variations in the interstitial solution of the concrete, providing qualitative information about the evolution of oxygen availability in concrete. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:226 / 232
页数:7
相关论文
共 25 条
[1]  
ALONSO C, 1998, P EUR 98 UTR
[2]   THE REDUCTION OF HYDROGEN-PEROXIDE ON PASSIVE IRON IN ALKALINE-SOLUTIONS [J].
CALVO, EJ ;
SCHIFFRIN, DJ .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1984, 163 (1-2) :257-275
[3]   THE ELECTROCHEMICAL REDUCTION OF OXYGEN ON PASSIVE IRON IN ALKALINE-SOLUTIONS [J].
CALVO, EJ ;
SCHIFFRIN, DJ .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1988, 243 (01) :171-185
[4]   Oxygen and chloride diffusion in cement pastes as a validation of chloride diffusion coefficients obtained by steady-state migration tests [J].
Castellote, M ;
Alonso, C ;
Andrade, C ;
Chadbourn, GA ;
Page, CL .
CEMENT AND CONCRETE RESEARCH, 2001, 31 (04) :621-625
[5]   Characterization of activated titanium solid reference electrodes for corrosion testing of steel in concrete [J].
Castro, P ;
Sagues, AA ;
Moreno, EI ;
Maldonado, L ;
Genesca, J .
CORROSION, 1996, 52 (08) :609-617
[6]  
CORREIA MJ, 2005, CORR PROT MAT, V24, P8
[7]  
Ferreira MGS, 2002, J BRAZIL CHEM SOC, V13, P433
[8]  
GJORV OE, 1986, MATER PERFORMANCE, V25, P39
[9]   OXYGEN REDUCTION ON IRON .6. PROCESSES IN ALKALINE-SOLUTIONS [J].
GOJKOVIC, SL ;
ZECEVIC, SK ;
DRAZIC, DM .
ELECTROCHIMICA ACTA, 1994, 39 (07) :975-982
[10]   THE ELECTRONIC-STRUCTURE OF PASSIVE FILMS FORMED ON STAINLESS-STEELS [J].
HAKIKI, NE ;
BOUDIN, S ;
RONDOT, B ;
BELO, MD .
CORROSION SCIENCE, 1995, 37 (11) :1809-1822