Three-dimensional computer-assisted study model analysis of long-term oral-appliance wear. Part 1: Methodology

被引:17
作者
Chen, Hui
Lowe, Alan A. [1 ]
de Almeida, Fernanda Riberiro [2 ]
Wong, Mary [1 ]
Fleetham, John A. [3 ]
Wang, Bangkang [4 ]
机构
[1] Univ British Columbia, Div Orthodont, Dept Oral Hlth Sci, Fac Dent, Vancouver, BC V5Z 1M9, Canada
[2] Univ British Columbia, Dept Oral Biol & Med Sci, Fac Dent, Vancouver, BC V5Z 1M9, Canada
[3] Univ British Columbia, Dept Med, Div Resp Med, Vancouver, BC V5Z 1M9, Canada
[4] Capital Univ Med Sci, Fac Stomatol, Beijing, Peoples R China
关键词
D O I
10.1016/j.ajodo.2006.10.030
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The aim of this study was to test a 3-dimensional (3D) computer-assisted dental model analysis system that uses selected landmarks to describe tooth movement during treatment with an oral appliance. Methods: Dental casts of 70 patients diagnosed with obstructive sleep apnea and treated with oral appliances for a mean time of 7 years 4 months were evaluated with a 3D digitizer (MicroScribe-3DX, Immersion, San Jose, Calif) compatible with the Rhinoceros modeling program (version 3.0 SR3c, Robert McNeel & Associates, Seattle, Wash). A total of 86 landmarks on each model were digitized, and 156 variables were calculated as either the linear distance between points or the distance from points to reference planes. Four study models for each patient (maxillary baseline, mandibular baseline, maxillary follow-up, and mandibular follow-up) were superimposed on 2 sets of reference points: 3 points on the palatal rugae for maxillary model superimposition, and 3 occlusal contact points for the same set of maxillary and mandibular model superimpositions. The patients were divided into 3 evaluation groups by 5 orthodontists based on the changes between baseline and follow-up study models. Results: Digital dental measurements could be analyzed, including arch width, arch length, curve of Spee, overbite, overjet, and the anteroposterior relationship between the maxillary and mandibular arches. A method error within 0.23 mm in 14 selected variables was found for the 3D system. The statistical differences in the 3 evaluation groups verified the division criteria determined by the orthodontists. Conclusions: The system provides a method to record 3D measurements of study models that permits computer visualization of tooth position and movement from various perspectives.
引用
收藏
页码:393 / 407
页数:15
相关论文
共 40 条
[1]   Natural craniofacial changes in the third decade of life:: A longitudinal study [J].
Akgül, AA ;
Toygar, TU .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2002, 122 (05) :512-522
[2]  
ALMEIDA MA, 1995, ANGLE ORTHOD, V65, P43
[3]  
[Anonymous], 1972, Orthodontics, principles and practice
[4]   A 3-dimensional analysis of molar movement during headgear treatment [J].
Ashmore, JL ;
Kurland, BF ;
King, GJ ;
Wheeler, TT ;
Ghafari, J ;
Ramsay, DS .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2002, 121 (01) :18-29
[5]  
Bailey LJ, 1996, ANGLE ORTHOD, V66, P73
[6]  
Bell A, 2003, J Orthod, V30, P219, DOI 10.1093/ortho/30.3.219
[7]   Development and evaluation of a new 3-D digitization and computer graphic system to study the anatomic tissue and restoration surfaces [J].
Dastane, A ;
Vaidyanathan, TK ;
Vaidyanathan, J ;
Mehra, R ;
Hesby, R .
JOURNAL OF ORAL REHABILITATION, 1996, 23 (01) :25-34
[8]  
Ferrario V F, 1999, Int J Adult Orthodon Orthognath Surg, V14, P153
[9]   Statistical evaluation of Monson's sphere in healthy permanent dentitions in man [J].
Ferrario, VF ;
Sforza, C ;
Miani, A .
ARCHIVES OF ORAL BIOLOGY, 1997, 42 (05) :365-369
[10]   Three-dimensional dental arch curvature in human adolescents and adults [J].
Ferrario, VF ;
Sforza, C ;
Poggio, CE ;
Serrao, G ;
Colombo, A .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1999, 115 (04) :401-405