RELIABILITY OF A NEW METHOD FOR ASSESSING TENSION AND CONFIGURATION OF TRANSOBTURATOR SUBURETHRAL TAPES USING FOUR-DIMENSIONAL ULTRASOUND

被引:4
作者
Yang, Jenn-Ming [1 ,2 ]
Yang, Shwu-Huey [3 ]
Huang, Wen-Chen [2 ,4 ,5 ]
Tzeng, Chii-Ruey [2 ,6 ]
机构
[1] Taipei Med Univ, Dept Obstet & Gynecol, Sch Med, Coll Med, Taipei, Taiwan
[2] Taipei Med Univ, Shuang Ho Hosp, Dept Obstet & Gynecol, Taipei, Taiwan
[3] Taipei Med Univ, Sch Nutr & Hlth Sci, Taipei, Taiwan
[4] Cathay Gen Hosp, Dept Obstet & Gynecol, Taipei, Taiwan
[5] Fu Jen Catholic Univ, Sch Med, Taipei, Taiwan
[6] Taipei Med Univ Hosp, Dept Obstet & Gynecol, Taipei, Taiwan
关键词
Introital ultrasound; Tape configuration; Tape tension; Transobturator suburethral tape; ANTI-INCONTINENCE PROCEDURES; OBTURATOR PROCEDURE; TVT; MONARC;
D O I
10.1016/j.ultrasmedbio.2012.08.020
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
We conducted this study to evaluate the intra-and interobserver reliability of a new method in assessing the tension and configuration of transobturator suburethral tape (TOT) at different tape points using 4-dimensional (4D) ultrasound. We randomly recruited 20 women following TOT procedures. Postoperative ultrasound datasets acquired during rest, straining, and coughing were digitally stored and analyzed offline by 2 independent and blinded investigators. The assessed parameters included axial tape-urethral distance, axial urethral central echolucent area, axial tape angle, and coronal tape angle at 5 equidistant tape points. For most parameters, the intraclass correlation coefficient and 95% confidence interval for intra-and interobserver reliability was higher than 0.70. 4D ultrasound can provide a quantitative method that meets minimal standards for reliability coefficients in assessing the tension and configuration of TOT. The reliability of the current method could be further evaluated when a whole new ultrasound examination was performed. (E-mail: huangwc0413@hotmail.com) (C) 2013 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:44 / 53
页数:10
相关论文
共 18 条
[1]   Sonographic appearance of transobturator slings: implications for function and dysfunction [J].
Chantarasorn, Varisara ;
Shek, Ka Lai ;
Dietz, Hans Peter .
INTERNATIONAL UROGYNECOLOGY JOURNAL, 2011, 22 (04) :493-498
[2]   Clinical and ultrasonographic correlations following three surgical anti-incontinence procedures (TOT, TVT and TVT-O) [J].
Chene, Gautier ;
Cotte, Benjamin ;
Tardieu, Anne-Sylvie ;
Savary, Denis ;
Mansoor, Aslam .
INTERNATIONAL UROGYNECOLOGY JOURNAL, 2008, 19 (08) :1125-1131
[3]   TVT vs Monarc: a comparative study [J].
Dietz, Hans Peter ;
Barry, Christopher ;
Lim, Yik ;
Rane, Ajay .
INTERNATIONAL UROGYNECOLOGY JOURNAL, 2006, 17 (06) :566-569
[4]   The 'iris effect': how two-dimensional and three-dimensional ultrasound can help us understand anti-incontinence procedures [J].
Dietz, HP ;
Wilson, PD .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2004, 23 (03) :267-271
[5]   Monarc transobturator sling system for the treatment of female urinary stress incontinence: results of a post-operative transvaginal ultrasonography [J].
Foulot, H. ;
Uzan, I. ;
Chopin, N. ;
Borghese, B. ;
Chapron, C. .
INTERNATIONAL UROGYNECOLOGY JOURNAL, 2007, 18 (08) :857-861
[6]   An International Urogynecological Association (IUGA)/International Continence Society (ICS) joint report on the terminology for female pelvic floor dysfunction [J].
Haylen, Bernard T. ;
de Ridder, Dirk ;
Freeman, Robert M. ;
Swift, Steven E. ;
Berghmans, Bary ;
Lee, Joseph ;
Monga, Ash ;
Petri, Eckhard ;
Rizk, Diaa E. ;
Sand, Peter K. ;
Schaer, Gabriel N. .
INTERNATIONAL UROGYNECOLOGY JOURNAL, 2010, 21 (01) :5-26
[7]  
Huang WC, 2011, ULTRASOUND OBSTET GY
[8]   Tape functionality: position, change in shape, and outcome after TVT procedure-mid-term results [J].
Kociszewski, Jacek ;
Rautenberg, Oliver ;
Kolben, Sebastian ;
Eberhard, Jakob ;
Hilgers, Reinhard ;
Viereck, Volker .
INTERNATIONAL UROGYNECOLOGY JOURNAL, 2010, 21 (07) :795-800
[9]   Guidelines for Reporting Reliability and Agreement Studies (GRRAS) were proposed [J].
Kottner, Jan ;
Audige, Laurent ;
Brorson, Stig ;
Donner, Allan ;
Gajewski, Byron J. ;
Hrobjartsson, Asbjorn ;
Roberts, Chris ;
Shoukri, Mohamed ;
Streiner, David L. .
JOURNAL OF CLINICAL EPIDEMIOLOGY, 2011, 64 (01) :96-106
[10]   Three-dimensional Doppler evaluation of single spherical samples from the placenta: intra- and interobserver reliability [J].
Martins, W. P. ;
Lima, J. C. ;
Welsh, A. W. ;
Araujo, E., Jr. ;
Miyague, A. H. ;
Filho, F. M. ;
Raine-Fenning, N. J. .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2012, 40 (02) :200-206