Performance evaluation of an integrated proton exchange membrane fuel cell system with ejector absorption refrigeration cycle

被引:21
作者
Toghyani, S. [1 ]
Afshari, E. [1 ]
Baniasadi, E. [1 ]
机构
[1] Univ Isfahan, Dept Mech Engn, Fac Engn, Hezar Jerib Ave, Esfahan 8174673441, Iran
关键词
PEM fuel cell; Absorption cooling system; Ejector; Reformer; Thermal driven cooling; Energy efficiency; COOLING SYSTEM; CHILLER; DESIGN; POWER; DRIVEN; OPTIMIZATION; PARAMETERS;
D O I
10.1016/j.enconman.2019.02.035
中图分类号
O414.1 [热力学];
学科分类号
摘要
Absorption chiller systems are advantageous to vapor compression cooling systems due to capability of utilizing low-grade heat sources such as waste heat from industries, renewable energies, and generated heat by fuel cell. The main issue in absorption cooling system is the low cycle coefficient of performance (COP) that can be addressed by integrated ejector-absorption cooling systems. In this study, an integrated system of proton exchange membrane (PEM) fuel cell that thermally drives an ejector-absorption refrigeration cycle is proposed. The effects of generator temperature, condenser pressure, evaporator pressure, and inlet fuel mass flow rate to the fuel cell on the ejector entrainment ratio (phi) and COP are evaluated. Moreover, the performance of the integrated system is evaluated at different geometrical and operating conditions of PEM fuel cell. The results reveal that the phi and COP parameters increase up to 18.51% and 48% by increasing the generator temperature from 70 degrees C to 100 degrees C, respectively. At higher inlet mass flow rate of fuel to the reformer, the cooling capacity and the system COP improve. Furthermore, the maximum value of phi and COP are 0.39 and 0.77, respectively, at the best operating condition of the PEM fuel cell, i.e. the current density of 0.75 A/cm(2). It is also concluded that the system overall energy efficiency at temperature of 80 degrees C and the current density of 0.5, 0.6, 0.75, and 0.85 A/cm(2) are 43%, 39%, 35%, 32%, and 37%, respectively. Moreover, the COP of absorption chiller with ejector at the operating pressure of 1 bar and the temperature of 80 degrees C for PEM fuel cell is 6.7% higher than conventional absorption chiller.
引用
收藏
页码:666 / 677
页数:12
相关论文
共 34 条
[1]   Alternative designs for a 24-hours operating solar-powered LiBr-water absorption air-conditioning technology [J].
Al-Ugla, A. A. ;
El-Shaarawi, M. A. I. ;
Said, S. A. M. .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2015, 53 :90-100
[2]   A model predicting transient responses of proton exchange membrane fuel cells [J].
Amphlett, JC ;
Mann, RF ;
Peppley, BA ;
Roberge, PR ;
Rodrigues, A .
JOURNAL OF POWER SOURCES, 1996, 61 (1-2) :183-188
[3]  
Anderson J. D., 1990, MODERN COMPRESSIBLE, V12
[4]   Exergetic and exergoeconomic evaluation of a trigeneration system based on natural gas-PEM fuel cell [J].
Baniasadi, Ehsan ;
Toghyani, Somayeh ;
Afshari, Ebrahim .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2017, 42 (08) :5327-5339
[5]   Investigation of a novel solar-driven refrigeration system with ejector [J].
Bellos, Evangelos ;
Theodosiou, Ioannis-Christos ;
Vellios, Loukas ;
Tzivanidis, Christos .
THERMAL SCIENCE AND ENGINEERING PROGRESS, 2018, 8 :284-295
[6]   Parametric analysis and optimization of a cooling system with ejector absorption chiller powered by solar parabolic trough collectors [J].
Bellos, Evangelos ;
Tzivanidis, Christos .
ENERGY CONVERSION AND MANAGEMENT, 2018, 168 :329-342
[7]   Optimum design of a solar ejector refrigeration system for various operating scenarios [J].
Bellos, Evangelos ;
Tzivanidis, Christos .
ENERGY CONVERSION AND MANAGEMENT, 2017, 154 :11-24
[8]  
Boyaghchi FA, 2014, INT J RENEW ENERGY R, V4, P902
[9]   Recent developments in ejector refrigeration technologies [J].
Chen, Xiangjie ;
Omer, Siddig ;
Worall, Mark ;
Riffat, Saffa .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2013, 19 :629-651
[10]   Ejectors: applications in refrigeration technology [J].
Chunnanond, K ;
Aphornratana, S .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2004, 8 (02) :129-155