Quantitative Multiparametric Breast Ultrasound Application of Contrast-Enhanced Ultrasound and Elastography Leads to an Improved Differentiation of Benign and Malignant Lesions
被引:78
作者:
Kapetas, Panagiotis
[1
]
Clauser, Paola
[1
]
Woitek, Ramona
[1
,2
]
Wengert, Georg J.
[1
]
Lazar, Mathias
[1
]
Pinker, Katja
[1
,3
]
Helbich, Thomas H.
[1
]
Baltzer, Pascal A. T.
[1
]
机构:
[1] Med Univ Vienna, Dept Biomed Imaging & Image Guided Therapy, Waehringer Guertel 18-20, A-1090 Vienna, Austria
[2] Univ Cambridge, Dept Radiol, Cambridge, England
[3] Mem Sloan Kettering Canc Ctr, Dept Radiol Mol Imaging & Therapy Serv, 1275 York Ave, New York, NY 10021 USA
关键词:
breast cancer;
multiparametric ultrasound;
elastography;
contrast-enhanced ultrasound;
Doppler ultrasound;
SHEAR-WAVE ELASTOGRAPHY;
COLOR DOPPLER US;
EXTRACELLULAR-MATRIX;
CONVENTIONAL ULTRASOUND;
CANCER;
DIAGNOSIS;
RADIOMICS;
RADIOLOGISTS;
INFORMATION;
MAMMOGRAPHY;
D O I:
10.1097/RLI.0000000000000543
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
Objectives: The aim of this study was to evaluate breast multiparametric ultrasound (mpUS) and its potential to reduce unnecessary breast biopsies with 1, 2, or 3 additional quantitative parameters (Doppler, elastography, and contrastenhanced ultrasound [CEUS]) to B-mode and investigate possible variationswith different reader experience. Materials and Methods: This prospective study included 124 women (age range, 18-82 years; mean, 52 years), each with 1 new breast lesion, scheduled for ultrasound-guided biopsy between October 2015 and September 2016. Each lesion was examined with B-mode, elastography (Virtual Touch IQ [VTIQ]), Doppler, and CEUS, and different quantitative parameterswere recorded for each modality. Four readers (2 experienced breast radiologists and 2 in-training) independently evaluated B-mode images of each lesion and assigned a BI-RADS (Breast Imaging Reporting and Data System) score. Using the area under the receiver operating characteristic curve (AUC), the most accurate quantitative parameter for each modality was chosen. These were then combined with the BI-RADS scores of all readers. Descriptive statistics and AUC were used to evaluate the diagnostic performance of mpUS. Results: Sixty-five lesions weremalignant. MpUS with B-mode and 2 additional quantitative parameters (VTIQ and CEUS or Doppler) showed the highest diagnostic performance for all readers (averaged AUCs, 0.812-0.789 respectively vs 0.683 for B-mode, P = 0.0001). Both combinations significantly reduced the number of false-positive findings up to 46.9% (P < 0.0001). Conclusions: Quantitative mpUS with 2 different triple assessment modalities (B-mode, VTIQ elastography, CEUS, or Doppler) shows the best diagnostic performance for breast cancer diagnosis and leads to a significant reduction of falsepositive biopsy recommendations, for both experienced and inexperienced readers.
引用
收藏
页码:257 / 264
页数:8