Quantitative Multiparametric Breast Ultrasound Application of Contrast-Enhanced Ultrasound and Elastography Leads to an Improved Differentiation of Benign and Malignant Lesions

被引:78
作者
Kapetas, Panagiotis [1 ]
Clauser, Paola [1 ]
Woitek, Ramona [1 ,2 ]
Wengert, Georg J. [1 ]
Lazar, Mathias [1 ]
Pinker, Katja [1 ,3 ]
Helbich, Thomas H. [1 ]
Baltzer, Pascal A. T. [1 ]
机构
[1] Med Univ Vienna, Dept Biomed Imaging & Image Guided Therapy, Waehringer Guertel 18-20, A-1090 Vienna, Austria
[2] Univ Cambridge, Dept Radiol, Cambridge, England
[3] Mem Sloan Kettering Canc Ctr, Dept Radiol Mol Imaging & Therapy Serv, 1275 York Ave, New York, NY 10021 USA
关键词
breast cancer; multiparametric ultrasound; elastography; contrast-enhanced ultrasound; Doppler ultrasound; SHEAR-WAVE ELASTOGRAPHY; COLOR DOPPLER US; EXTRACELLULAR-MATRIX; CONVENTIONAL ULTRASOUND; CANCER; DIAGNOSIS; RADIOMICS; RADIOLOGISTS; INFORMATION; MAMMOGRAPHY;
D O I
10.1097/RLI.0000000000000543
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: The aim of this study was to evaluate breast multiparametric ultrasound (mpUS) and its potential to reduce unnecessary breast biopsies with 1, 2, or 3 additional quantitative parameters (Doppler, elastography, and contrastenhanced ultrasound [CEUS]) to B-mode and investigate possible variationswith different reader experience. Materials and Methods: This prospective study included 124 women (age range, 18-82 years; mean, 52 years), each with 1 new breast lesion, scheduled for ultrasound-guided biopsy between October 2015 and September 2016. Each lesion was examined with B-mode, elastography (Virtual Touch IQ [VTIQ]), Doppler, and CEUS, and different quantitative parameterswere recorded for each modality. Four readers (2 experienced breast radiologists and 2 in-training) independently evaluated B-mode images of each lesion and assigned a BI-RADS (Breast Imaging Reporting and Data System) score. Using the area under the receiver operating characteristic curve (AUC), the most accurate quantitative parameter for each modality was chosen. These were then combined with the BI-RADS scores of all readers. Descriptive statistics and AUC were used to evaluate the diagnostic performance of mpUS. Results: Sixty-five lesions weremalignant. MpUS with B-mode and 2 additional quantitative parameters (VTIQ and CEUS or Doppler) showed the highest diagnostic performance for all readers (averaged AUCs, 0.812-0.789 respectively vs 0.683 for B-mode, P = 0.0001). Both combinations significantly reduced the number of false-positive findings up to 46.9% (P < 0.0001). Conclusions: Quantitative mpUS with 2 different triple assessment modalities (B-mode, VTIQ elastography, CEUS, or Doppler) shows the best diagnostic performance for breast cancer diagnosis and leads to a significant reduction of falsepositive biopsy recommendations, for both experienced and inexperienced readers.
引用
收藏
页码:257 / 264
页数:8
相关论文
共 50 条
[1]  
[Anonymous], 2016, Imaging Biomarkers: Development and Clinical Integration, DOI DOI 10.1007/978-3-319-43504-61
[2]  
[Anonymous], QUANT IM BIOM ALL QI
[3]   Breast Lesions: Quantitative Elastography with Supersonic Shear Imaging-Preliminary Results [J].
Athanasiou, Alexandra ;
Tardivon, Anne ;
Tanter, Mickael ;
Sigal-Zafrani, Brigitte ;
Bercoff, Jeremy ;
Eux, Thomas Deffi ;
Gennisson, Jean-Luc ;
Fink, Mathias ;
Neuenschwander, Sylvia .
RADIOLOGY, 2010, 256 (01) :297-303
[4]   Detection of Breast Cancer With Addition of Annual Screening Ultrasound or a Single Screening MRI to Mammography in Women With Elevated Breast Cancer Risk [J].
Berg, Wendie A. ;
Zhang, Zheng ;
Lehrer, Daniel ;
Jong, Roberta A. ;
Pisano, Etta D. ;
Barr, Richard G. ;
Boehm-Velez, Marcela ;
Mahoney, Mary C. ;
Evans, W. Phil, III ;
Larsen, Linda H. ;
Morton, Marilyn J. ;
Mendelson, Ellen B. ;
Farria, Dione M. ;
Cormack, Jean B. ;
Marques, Helga S. ;
Adams, Amanda ;
Yeh, Nolin M. ;
Gabrielli, Glenna .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2012, 307 (13) :1394-1404
[5]   Shear-wave Elastography Improves the Specificity of Breast US: The BE1 Multinational Study of 939 Masses [J].
Berg, Wendie A. ;
Cosgrove, David O. ;
Dore, Caroline J. ;
Schaefer, Fritz K. W. ;
Svensson, William E. ;
Hooley, Regina J. ;
Ohlinger, Ralf ;
Mendelson, Ellen B. ;
Balu-Maestro, Catherine ;
Locatelli, Martina ;
Tourasse, Christophe ;
Cavanaugh, Barbara C. ;
Juhan, Valerie ;
Stavros, A. Thomas ;
Tardivon, Anne ;
Gay, Joel ;
Henry, Jean-Pierre ;
Cohen-Bacrie, Claude .
RADIOLOGY, 2012, 262 (02) :435-449
[6]   Long-Term Psychosocial Consequences of False-Positive Screening Mammography [J].
Brodersen, John ;
Siersma, Volkert Dirk .
ANNALS OF FAMILY MEDICINE, 2013, 11 (02) :106-115
[7]   Distinguishing Benign from Malignant Masses at Breast US: Combined US Elastography and Color Doppler US-Influence on Radiologist Accuracy [J].
Cho, Nariya ;
Jang, Mijung ;
Lyou, Chae Yeon ;
Park, Jeong Seon ;
Choi, Hye Young ;
Moon, Woo Kyung .
RADIOLOGY, 2012, 262 (01) :80-90
[8]   Additional diagnostic value of shear-wave elastography and color Doppler US for evaluation of breast non-mass lesions detected at B-mode US [J].
Choi, Ji Soo ;
Han, Boo-Kyung ;
Ko, Eun Young ;
Ko, Eun Sook ;
Shin, Jung Hee ;
Kim, Ga Ram .
EUROPEAN RADIOLOGY, 2016, 26 (10) :3542-3549
[9]  
Choi JY, 2018, NUCL MED MOLEC IMAG, V52, P89, DOI 10.1007/s13139-018-0514-0
[10]   Differentiating benign from malignant solid breast lesions: Combined utility of conventional ultrasound and contrast-enhanced ultrasound in comparison with magnetic resonance imaging [J].
Du, Jing ;
Wang, Lin ;
Wan, Cai-Feng ;
Hua, Jia ;
Fang, Hua ;
Chen, Jie ;
Li, Feng-Hua .
EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (12) :3890-3899