Independent knowledge-based treatment planning QA to audit Pinnacle autoplanning

被引:23
作者
Janssen, Tomas M.
Kusters, Martijn
Wang, Yibing
Wortel, Geert
Monshouwer, Rene
Damen, Eugene
Petit, Steven F.
机构
[1] Netherlands Canc Inst, Dept Radiat Oncol, Amsterdam, Netherlands
[2] Radboud Univ Nijmegen, Dept Radiat Oncol, Nijmegen, Netherlands
[3] Erasmus MC Canc Inst, Dept Radiat Oncol, Rotterdam, Netherlands
关键词
Knowledge based planning; Autoplanning; MODULATED ARC THERAPY; RADIATION-THERAPY; QUALITY; OPTIMIZATION; GENERATION; VALIDATION; HEAD;
D O I
10.1016/j.radonc.2018.10.035
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: With the advent of automatic treatment planning options like Pinnacle's Autoplanning (PAP), the challenge arises how to assess the quality of a plan that no dosimetrist did work on. The aim of this study was to assess plan quality consistency of PAP prostate cancer patients in clinical practice. Materials and methods: 100 prostate cancer patients were included from NKI and 129 from RadboudUMC (RUMC). Per institute a previously developed [1] treatment planning QA model, based on overlap volume histograms, was trained on PAP plans to predict achievable dose metrics which were then compared to the clinical PAP plans. A threshold of 3 Gy (DVH dose parameters)/3% (DVH volume parameters) was used to detect outliers. For the outlier plans, the PAP technique was adjusted with the aim of meeting the threshold. Results: The average difference between the prediction and the clinically achieved value was < 0.5 Gy (mean dose parameters) and < 1.2% (volume parameters), with standard deviation of 1.9 Gy/1.5% respectively. We found 8% (NKI)/25% (RUMC) of patients to exceed the 3 Gy/3% threshold, with deviations up to 6.7 Gy (mean dose rectum) and 6% (rectal wall V64Gy). In all cases the plans could be improved to fall within the thresholds, without compromising the other dose metrics. Conclusion: Independent treatment planning QA was used successfully to assess the quality of clinical PAP in a multi-institutional setting. Respectively 8% and 25% suboptimal clinical PAP plans were detected that all could be improved with replanning. Therefore we recommend the use of independent treatment plan QA in combination with PAP for prostate cancer patients. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:198 / 204
页数:7
相关论文
共 23 条
[1]   Predicting dose-volume histograms for organs-at-risk in IMRT planning [J].
Appenzoller, Lindsey M. ;
Michalski, Jeff M. ;
Thorstad, Wade L. ;
Mutic, Sasa ;
Moore, Kevin L. .
MEDICAL PHYSICS, 2012, 39 (12) :7446-7461
[2]   Interobserver variability in radiation therapy plan output: Results of a single-institution study [J].
Berry, Sean L. ;
Boczkowski, Amanda ;
Ma, Rongtao ;
Mechalakos, James ;
Hunt, Margie .
PRACTICAL RADIATION ONCOLOGY, 2016, 6 (06) :442-449
[3]   Knowledge-based IMRT treatment planning for prostate cancer [J].
Chanyavanich, Vorakarn ;
Das, Shiva K. ;
Lee, William R. ;
Lo, Joseph Y. .
MEDICAL PHYSICS, 2011, 38 (05) :2515-2522
[4]  
Fogliata A, 2017, RAD ONCOL, V12
[5]   On the pre-clinical validation of a commercial model-based optimisation engine: Application to volumetric modulated arc therapy for patients with lung or prostate cancer [J].
Fogliata, Antonella ;
Belosi, Francesca ;
Clivio, Alessandro ;
Navarria, Piera ;
Nicolini, Giorgia ;
Scorsetti, Marta ;
Vanetti, Eugenio ;
Cozzi, Luca .
RADIOTHERAPY AND ONCOLOGY, 2014, 113 (03) :385-391
[6]   Initial evaluation of automated treatment planning software [J].
Gintz, Dawn ;
Latifi, Kujtim ;
Caudell, Jimmy ;
Nelms, Benjamin ;
Zhang, Geoffrey ;
Moros, Eduardo ;
Feygelman, Vladimir .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (03) :331-346
[7]  
Hansen Christian Ronn, 2016, Clin Transl Radiat Oncol, V1, P2, DOI 10.1016/j.ctro.2016.08.001
[8]   Automatic treatment planning facilitates fast generation of high-quality treatment plans for esophageal cancer [J].
Hansen, Christian Ronn ;
Nielsen, Morten ;
Bertelsen, Anders Smedegaard ;
Hazell, Irene ;
Holtved, Eva ;
Zukauskaite, Ruta ;
Bjerregaard, Jon Kroll ;
Brink, Carsten ;
Bernchou, Uffe .
ACTA ONCOLOGICA, 2017, 56 (11) :1495-1500
[9]   Automatic planning of head and neck treatment plans [J].
Hazell, Irene ;
Bzdusek, Karl ;
Kumar, Prashant ;
Hansen, Christian R. ;
Bertelsen, Anders ;
Eriksen, Jesper G. ;
Johansen, Jorgen ;
Brink, Carsten .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (01) :272-282
[10]   Evaluation of concave dose distributions created using an inverse planning system [J].
Hunt, MA ;
Hsiung, CY ;
Spirou, SV ;
Chui, CS ;
Amols, HI ;
Ling, CC .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 54 (03) :953-962