Seismic response mitigation of chemical plant components by passive control techniques

被引:62
作者
Paolacci, F. [1 ]
Giannini, R. [1 ]
De Angelis, M. [2 ]
机构
[1] Univ Roma Tre, Dept Struct, I-00146 Rome, Italy
[2] Univ Roma La Sapienza, Dept Struct & Geotech Engn, I-00184 Rome, Italy
关键词
Chemical plants; Seismic response; Passive control; RISK-ASSESSMENT; STORAGE TANKS; EARTHQUAKE; DESIGN; SYSTEMS; RELIABILITY; PERFORMANCE; PROTECTION; FACILITIES; EQUIPMENT;
D O I
10.1016/j.jlp.2013.03.003
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
This paper deals with the applicability of seismic passive control in major-hazard chemical installations. The objective is to show numerically and experimentally the applicability of Passive Control Techniques (PCT) in industrial plants. Consequently, the main components of a process plant are classified and collected into a limited number of classes; for each class, the main damages caused by past earthquakes are described and the most vulnerable components are identified. A synthesis of the effects of earthquakes on the different typologies of process components is also presented and the most suitable innovative seismic protection systems, in particular passive control techniques (PCT), are acknowledged. Finally, the effectiveness of PCT in reducing the seismic response of process plant components is proved by three representative case studies: a base isolated above-ground storage tank, a distillation column connected by elastoplastic dampers to the adjacent service frame and an application of non-conventional Tuned Mass Dampers to a support frame. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:924 / 935
页数:12
相关论文
共 77 条
[1]  
Addessi D., 2001, 7 INT SEM SEISM IS P
[2]   Reliability of base isolation for the protection of critical equipment from earthquake hazards [J].
Alhan, C ;
Gavin, HP .
ENGINEERING STRUCTURES, 2005, 27 (09) :1435-1449
[3]   A methodology for the quantitative risk assessment of major accidents triggered by seismic events [J].
Antonioni, Giacomo ;
Spadoni, Gighola ;
Cozzani, Valerio .
JOURNAL OF HAZARDOUS MATERIALS, 2007, 147 (1-2) :48-59
[4]   Optimum X-plate dampers for seismic response control of piping systems [J].
Bakre, S. V. ;
Jangid, R. S. ;
Reddy, G. R. .
INTERNATIONAL JOURNAL OF PRESSURE VESSELS AND PIPING, 2006, 83 (09) :672-685
[5]  
Bakre S. V., 2004, 13 WCEE VANC B C CAN
[6]   EFFECTIVENESS OF TUNED LIQUID COLUMN DAMPERS FOR VIBRATION CONTROL OF TOWERS [J].
BALENDRA, T ;
WANG, CM ;
CHEONG, HF .
ENGINEERING STRUCTURES, 1995, 17 (09) :668-675
[7]  
Ballantyne D., 1991, EARTHQ SPECTRA, V7, P93, DOI DOI 10.1193/1.1585664
[8]   A reduced order model for optimal design of 2-mdof adjacent structures connected by hysteretic dampers [J].
Basili, M. ;
De Angelis, M. .
JOURNAL OF SOUND AND VIBRATION, 2007, 306 (1-2) :297-317
[9]   Optimal passive control of adjacent structures interconnected with nonlinear hysteretic devices [J].
Basili, M. ;
De Angelis, M. .
JOURNAL OF SOUND AND VIBRATION, 2007, 301 (1-2) :106-125
[10]  
Basili M., 2013, J SOUND VIBRATION