Improving the Performance of Light Pipe System Using Laser Cut Panel

被引:2
作者
Abd Kadir, Aslila [1 ]
Ismail, Lokman Hakim [2 ]
Kasim, Narimah [3 ]
Abd Wahab, Izudinshah [2 ]
Kaamin, Masiri [1 ]
Ngadiman, Norhayati Binti [1 ]
Rosli, Mohd Shafiq Bin Mohd [2 ]
机构
[1] Univ Tun Hussein Onn Malaysia, Ctr Diploma Studies, Dept Civil Engn, Parit Raja, Johor, Malaysia
[2] Univ Tun Hussein Onn Malaysia, Dept Design Engn & Architecture, Fac Civil & Environm Engn, Parit Raja, Johor, Malaysia
[3] Univ Tun Hussein Onn Malaysia, Dept Construct Management, Fac Technol Management & Business, Parit Raja, Johor, Malaysia
来源
INTERNATIONAL CONFERENCE ON MECHANICAL AND MANUFACTURING ENGINEERING (ICME2018) | 2019年 / 1150卷
关键词
D O I
10.1088/1742-6596/1150/1/012064
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Light pipe systems (LPS) are simple devices that allow the transmission of daylight into interiors of buildings. It is a convenient concept for illumination of windowless parts of buildings. The light performance of this is highly dependent on the solar altitude due to the small inlet aperture. Placing the laser-cut panel (LCP) at the entrance aperture in light pipe system, will increase the light performance during low solar angle. This paper presents the results of light performance a 400mm diameter light pipe integrated with a laser-cut panel at entrance aperture as collector. For that reason, this research adopted an experimental approach to compare the light pipe performance via 1: 10 scale model. Two scale models were built. LCP in the form of pyramids was fitted at the entrance aperture of light pipe in different tilted angle 40 degrees and 47.5 degrees. The system has been monitored 30 minutes interval with lux meter to evaluate the improvement light performance on a working plane for 6 days under good sky condition. The results of this experiment shows that LCP with 40 degrees tilted angle performed better than 47.5 degrees tilted angle. The light pipe with LCP as collector the minimum recommended illuminance by Malaysian Standard (MS) 1525: 2007 can be achieved as early at 8am.
引用
收藏
页数:7
相关论文
共 13 条
[1]   POTENTIAL OF LIGHT PIPES SYSTEM IN MALAYSIAN CLIMATE [J].
Abd Kadir, Aslila ;
Ismail, Lokman Hakim ;
Kasim, Narimah ;
Kaamin, Masiri .
INTERNATIONAL ENGINEERING RESEARCH AND INNOVATION SYMPOSIUM (IRIS), 2016, 160
[2]   A field study of tubular daylight guidance installations [J].
Al Marwaee, M. ;
Carter, D. J. .
LIGHTING RESEARCH & TECHNOLOGY, 2006, 38 (03) :241-258
[3]   User attitudes toward tubular daylight guidance systems Reply to comment [J].
Carter, D. J. ;
Al Marwaee, M. .
LIGHTING RESEARCH & TECHNOLOGY, 2009, 41 (01) :87-88
[4]   Developments in tubular daylight guidance systems [J].
Carter, DJ .
BUILDING RESEARCH AND INFORMATION, 2004, 32 (03) :220-234
[5]  
Edmonds I.R., 1995, LIGHTING RES TECHNOL, V27, P27, DOI [10.1177/14771535950270010101, DOI 10.1177/14771535950270010101]
[6]   Daylighting in the tropics [J].
Edmonds, IR ;
Greenup, PJ .
SOLAR ENERGY, 2002, 73 (02) :111-121
[7]  
EDMONDS IR, 1996, LIGHTING RES TECHNOL, V28, P122
[8]   Tubular light guide evaluation [J].
Mohelnikova, Jitka .
BUILDING AND ENVIRONMENT, 2009, 44 (10) :2193-2200
[9]   Potential of fibre optic daylighting systems in tropical Malaysia [J].
Munaaim, Muhammad Arkam Che ;
Al-Obaidi, Karam Mustafa ;
Ismail, Mohd Rodzi ;
Rahman, Abdul Malek Abdul .
INDOOR AND BUILT ENVIRONMENT, 2016, 25 (03) :466-480
[10]   Daylight enhancement using laser cut panels integrated with a profiled Fresnel collector [J].
Nair, M. G. ;
Ganesan, A. R. ;
Ramamurthy, K. .