Diminished adhesion and activation of platelets and neutrophils with CD47 functionalized blood contacting surfaces

被引:48
作者
Finley, Matthew J. [1 ,2 ]
Rauova, Lubica [2 ,3 ]
Alferiev, Ivan S. [1 ,2 ]
Weisel, John W. [2 ,4 ]
Levy, Robert J. [1 ,2 ]
Stachelek, Stanley J. [1 ,2 ]
机构
[1] Childrens Hosp Philadelphia, Dept Pediat, Div Cardiol, Philadelphia, PA 19104 USA
[2] Univ Penn, Perelman Sch Med, Philadelphia, PA 19104 USA
[3] Childrens Hosp Philadelphia, Dept Pediat, Div Hematol, Philadelphia, PA 19104 USA
[4] Univ Penn, Dept Cell & Dev Biol, Perelman Sch Med, Philadelphia, PA 19104 USA
关键词
Blood compatibility; Biomimetic material; Surface modification; Platelet adhesion; Platelet activation; INTEGRIN-ASSOCIATED PROTEIN; INFLAMMATORY RESPONSE; CARDIOPULMONARY BYPASS; COMPLEMENT; CIRCUITS; INJURY;
D O I
10.1016/j.biomaterials.2012.04.051
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
CD47 is a ubiquitously expressed transmembrane protein that, through signaling mechanisms mediated by signal regulatory protein alpha (SIRP alpha 1), functions as a biological marker of 'self-recognition'. We showed previously that inflammatory cell attachment to polymeric surfaces is inhibited by the attachment of biotinylated recombinant CD47 (CD47B). We test herein the hypothesis that C047 modified blood conduits can reduce platelet and neutrophil activation under clinically relevant conditions. We appended a poly-lysine tag to the C-terminus of recombinant CD47 (CD47L) allowing for covalent linkage to the polymer. SIRPa1 expression was confirmed in isolated platelets. We then compared biocompatibility between CD47B and CD47L functionalized polyvinyl chloride (PVC) surfaces and unmodified control PVC surfaces. Quantitative and Qualitative analysis of blood cell attachment to CD47B and CD47L surfaces, via scanning electron microscopy, showed strikingly fewer platelets attached to CD47 modified surfaces compared to control. Flow cytometry analysis showed that activation markers for neutrophils (CD62L) and platelets (CD62P) exposed to CD47 modified PVC were equivalent to freshly acquired control blood, while significantly elevated in the unmodified PVC tubing. In addition, ethylene oxide gas sterilization did not inhibit the efficacy of the CD47 modification. In conclusion, CD47 modified PVC inhibits both the adhesion and activation of platelets and neutrophils. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:5803 / 5811
页数:9
相关论文
共 42 条
[1]  
Barner HB, 1998, ANN THORAC SURG, V66, pS25
[2]   Integrin-associated protein (CD47) and its ligands [J].
Brown, EJ ;
Frazier, WA .
TRENDS IN CELL BIOLOGY, 2001, 11 (03) :130-135
[3]  
BRUCK SD, 1982, MED PROG TECHNOL, V9, P1
[4]   Thrombospondin acts via integrin-associated protein to activate the platelet integrin alpha(IIb)beta(3) [J].
Chung, J ;
Gao, AG ;
Frazier, WA .
JOURNAL OF BIOLOGICAL CHEMISTRY, 1997, 272 (23) :14740-14746
[5]   Lung injury after cardiopulmonary bypass [J].
Clark, Stephen C. .
PERFUSION-UK, 2006, 21 (04) :225-228
[6]   Coated versus noncoated circuits in pediatric cardiopulmonary bypass [J].
Draaisma, AM ;
Hazekamp, MG .
ASAIO JOURNAL, 2005, 51 (05) :663-664
[7]   Inflammatory response to cardiopulmonary bypass [J].
Edmunds, LH .
ANNALS OF THORACIC SURGERY, 1998, 66 (05) :S12-S16
[8]   Effect of polymer coating (poly 2-methoxyethylacrylate) of the oxygenator on hemostatic markers during cardiopulmonary bypass in children [J].
Eisses, Michael J. ;
Geiduschek, Jeremy M. ;
Jonmarker, Christer ;
Cohen, Gordon A. ;
Chandler, Wayne L. .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2007, 21 (01) :28-34
[9]   Platelet-leukocyte aggregates during hemodialysis: Effect of membrane type [J].
Gawaz, MP ;
Mujais, SK ;
Schmidt, B ;
Blumenstein, M ;
Gurland, HJ .
ARTIFICIAL ORGANS, 1999, 23 (01) :29-36
[10]   BLOOD ANESTHESIA FOR CARDIOPULMONARY BYPASS [J].
GORMAN, JH ;
EDMUNDS, LH .
JOURNAL OF CARDIAC SURGERY, 1995, 10 (03) :270-279