Influence of Soil Reinforcement on Horizontal Displacement of MSE Wall

被引:39
作者
Kibria, Golam [1 ]
Hossain, Sahadat [1 ]
Khan, Mohammad Sadik [1 ]
机构
[1] Univ Texas Arlington, Dept Civil Engn, Arlington, TX 76019 USA
关键词
RETAINING WALLS; FAILURE MECHANISMS; BEHAVIOR; BACKFILL; MODEL;
D O I
10.1061/(ASCE)GM.1943-5622.0000297
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
Mechanically stabilized earth (MSE) walls offer simple construction techniques, pleasing aesthetics, and cost-effective solutions as an alternative to conventional gravity walls. However, design and construction should be carefully evaluated to achieve satisfactory performance of the wall. A case study is presented on a MSE wall located on State Highway 342 in Lancaster, Texas. The horizontal movement of the MSE wall was between 300 and 450 mm within 5 years of construction. A forensic investigation was performed to determine the causes of the excessive movement. It was identified that inadequate reinforcement length was one of the contributing factors that caused horizontal displacement of the MSE wall. The objective of this study was to determine the effects of soil reinforcement on excessive movement of the MSE wall. As a part of the forensic investigation, two inclinometers were installed at the site to monitor any additional movement of the MSE wall. The inclinometer results suggested that the wall continued to move at an average rate of 4.5 mm/month during the investigation period. A finite-element (FE) program was used to simulate horizontal displacement and stability of the MSE wall. It was observed that the numerical modeling results were in good agreement with inclinometer results. A parametric study was conducted to identify the effects of soil reinforcement on horizontal movement at varied wall heights and backfill conditions. Numerical analyses results indicated that the effect of reinforcement stiffness was not significant at a wall height of 4 m compared with 8 and 12 m. The wall movement varied from 74 to 29 mm for an increase in reinforcement stiffness from 250 to 42,000 kN=m at 1:0H reinforcement length. The variations in displacement with reinforcement lengths suggested that substantial reduction in displacement occurred for an increase in length-height (L=H) ratio from 0.5 to 0.7. FE modeling results were used for sensitivity analysis employing a statistical analysis program. Based on the analyses, reinforcement length and stiffness were identified as influential factors for the horizontal displacement of MSE walls at a specific height. © 2014 American Society of Civil Engineers.
引用
收藏
页码:130 / 141
页数:12
相关论文
共 35 条
[1]   Numerical analysis of the behaviour of mechanically stabilized earth walls reinforced with different types of strips [J].
Abdelouhab, Abdelkader ;
Dias, Daniel ;
Freitag, Nicolas .
GEOTEXTILES AND GEOMEMBRANES, 2011, 29 (02) :116-129
[2]  
[Anonymous], 2008, SAS 9.2
[3]  
[Anonymous], 2002, Standard Specifications for Highway Bridges
[4]   2D and 3D numerical simulations of reinforced embankments on soft ground [J].
Bergado, Dennes T. ;
Teerawattanasuk, Chairat .
GEOTEXTILES AND GEOMEMBRANES, 2008, 26 (01) :39-55
[5]  
Bilgin O, 2010, EARTH RET C, V3, P556
[6]   Failure mechanisms governing reinforcement length of geogrid reinforced soil retaining walls [J].
Bilgin, Oemer .
ENGINEERING STRUCTURES, 2009, 31 (09) :1967-1975
[7]   Reliability-based design for internal stability of mechanically stabilized earth walls [J].
Chalermyanont, T ;
Benson, CH .
JOURNAL OF GEOTECHNICAL AND GEOENVIRONMENTAL ENGINEERING, 2004, 130 (02) :163-173
[8]  
Chalermyanont T, 2005, International Journal of Geomechanics, V5, P196
[9]  
CHEW SH, 1991, PERFORMANCE OF REINFORCED SOIL STRUCTURES, P35
[10]  
Collin J. G., 1986, THESIS