Effects of impeller and baffle dimensions on power consumption under turbulent flow in an agitated vessel with paddle impeller

被引:56
|
作者
Kamei, N [1 ]
Hiraoka, S [1 ]
Kato, Y [1 ]
Tada, Y [1 ]
Iwata, K [1 ]
Murai, K [1 ]
Lee, YS [1 ]
Yamaguchi, T [1 ]
Koh, ST [1 ]
机构
[1] NAGOYA INST TECHNOL,DEPT APPL CHEM,SHOWA KU,NAGOYA,AICHI 466,JAPAN
关键词
power consumption; paddle impeller; impeller dimension; baffle dimension; fully condition;
D O I
10.1252/kakoronbunshu.22.249
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Power Consumption under turbulent flow in a baffled agitated vessel with paddle impeller was measured for different impeller dimensions. The power number at the standard baffle condition was then correlated well with a parameter n(p)(0.7)(b/d), where b, d and n(p) are impeller blade width, impeller diameter and the number of impeller blades, respectively. The power correlation under fully baffled conditions was derived using the parameter n(p)(0.7)(b/d). On the other hand, from a model analysis of the drag force acting on a baffle plate, the power number under weakly baffled conditions was correlated well with the parameter (B-w/D)n(b)(0.8), where B-w, D and n(b) are baffle plate width, vessel diameter and the number of baffle plates, respectively. The resultant correlation was expressed as N-p-N-p0=4.5(B-w/D)n(b)(0.8)N(pmax)(0.8) where N-p0 and N-pmax were power number under non-baffled conditions and that under fully baffled conditions, respectively. From the derivation of the power correlation over wide range of baffle and impeller dimensions, the fully baffled condition was expressed by the following equation (B-w/D)n(b)(0.8)=0.27N(pmax)(0.2)
引用
收藏
页码:249 / 256
页数:8
相关论文
共 50 条
  • [1] Effect of baffle dimensions on liquid free surface in an agitated vessel with paddle impeller
    Kamei, N
    Hiraoka, S
    Kato, Y
    Tada, Y
    Yabuuchi, K
    KAGAKU KOGAKU RONBUNSHU, 1999, 25 (01) : 12 - 17
  • [2] Effect of impeller and baffle dimensions on vortex depth of liquid free surface in an agitated vessel with pitched blade paddle impeller
    Kamei, N
    Hiraoka, S
    Kato, Y
    Tada, Y
    Yamazaki, K
    KAGAKU KOGAKU RONBUNSHU, 2004, 30 (01) : 105 - 107
  • [3] EFFECTS OF IMPELLER DIMENSIONS AND POSITION ON POWER-CONSUMPTION IN A BAFFLED AGITATED VESSEL
    KAMEI, N
    HIRAOKA, S
    KATO, Y
    TADA, Y
    ISHIZUKA, H
    IWATA, K
    LEE, YS
    YAMAGUCHI, T
    KOH, ST
    KAGAKU KOGAKU RONBUNSHU, 1995, 21 (04) : 696 - 702
  • [4] 2 DIMENSIONAL MODEL ANALYSIS OF TURBULENT-FLOW IN AN AGITATED VESSEL WITH PADDLE IMPELLER
    HIRAOKA, S
    FAN, LT
    CHEMICAL ENGINEERING COMMUNICATIONS, 1981, 10 (1-3) : 149 - 164
  • [5] Power consumption of impeller in agitated vessel of continuous flow system
    Ito, Ryuzo
    Hirata, Yushi
    Sakata, Kei
    Nakahara, Isamu
    Kagaku Kogaku Ronbunshu, 1978, 4 (03) : 267 - 272
  • [6] Effect of Baffle Length on Power Consumption in Turbulent Mixing Vessel with Rushton Turbine Impeller
    Kato, Yoshihito
    Kamei, Noboru
    Tada, Yutaka
    Nakaoka, Azusa
    Nagatsu, Yuichiro
    Koh, Song-Tae
    Lee, Young-Sei
    KAGAKU KOGAKU RONBUNSHU, 2011, 37 (02) : 147 - 149
  • [7] Effects of impeller and baffle conditions on mixing time in turbulent agitated vessels
    Kamei, N
    Hiraoka, S
    Kato, Y
    Tada, Y
    Yamazaki, K
    KAGAKU KOGAKU RONBUNSHU, 2002, 28 (01) : 9 - 15
  • [8] Power consumption and mixing time in an agitated vessel with double impeller
    Hiraoka, S
    Kato, Y
    Tada, Y
    Ozaki, N
    Murakami, Y
    Lee, YS
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2001, 79 (A8): : 805 - 810
  • [9] Power consumption in agitated vessels with dual Rushton turbines: Baffle length and impeller spacing effects
    Markopoulos, J
    Babalona, E
    Tsiliopoulou, E
    CHEMICAL ENGINEERING & TECHNOLOGY, 2004, 27 (11) : 1212 - 1215
  • [10] Turbulent Flow Field in a Stirred Vessel Agitated by an Impeller with Flexible Blades
    Liang, Yangyang
    Shi, Daien
    Xu, Bohang
    Cai, Ziqi
    Gao, Zhengming
    AICHE JOURNAL, 2018, 64 (11) : 4148 - 4161