High-throughput micro-solid phase extraction on 96-well plate using dodecyl methacrylate-ethylen glycol dimethacrylate monolithic copolymer

被引:16
|
作者
Bagheri, Habib [1 ]
Es'haghi, Ali [1 ]
Es-haghi, Ali [2 ]
Mohammadkhani, Elham [1 ]
机构
[1] Sharif Univ Technol, Dept Chem, Environm & Bioanalyt Labs, Tehran, Iran
[2] Razi Vaccine & Serum Res Inst, Dept Phys Chem, Karaj, Iran
关键词
High-throughput; 96-Well plate; Monolithic polymer; Pesticide multiresidue; Micro-solid phase extraction; CHROMATOGRAPHY-MASS SPECTROMETRY; BAR SORPTIVE EXTRACTION; LIQUID-CHROMATOGRAPHY; PESTICIDE-RESIDUES; POLYMER MONOLITHS; MICROEXTRACTION; WATER; SAMPLES; FORMAT; OPTIMIZATION;
D O I
10.1016/j.aca.2013.07.020
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel high-throughput device based on 96-micro-solid phase extraction (96-mu-SPE) system was constructed for multiresidue determination of nine pesticides in aquatic samples. The extraction procedure was performed on a commercially available 96-well plate system. The extraction module consisted of 96 pieces of 1 cm x 3 cm of cylindrically shaped stainless steel meshes. The prepared meshes were fixed in a home-made polytetrafluoroethylene-based constructed ninety-six holes block for possible simultaneous immersion of meshes into the center of individual wells. Dodecyl methacrylate and ethylene glycol dimethacrylate was copolymerized as a monolithic polymer and placed in the cylindrically shaped stainless steel meshes as extracting medium. A volume of 1 mL of the aquatic sample was transferred into the 96-well plate and the 96-mu-SPE device was applied for the extraction of the selected pesticides. Subsequently, the extracted analytes were analyzed by gas chromatography-mass spectrometry. Influential parameters such as polymer synthesis conditions, sorbent-to-sorbent reproducibility, ionic strength and extraction time were optimized. Intra and inter-sorbent reproducibility on 96-mu-SPE device were evaluated and results revealed that extraction yields are rather similar. Limits of detection were below 4 mu g L-1 and the coefficient of determination was satisfactory (r(2) > 0.99) for all the studied analytes. The developed method was successfully applied to the extraction and determination of the selected pesticides in surface water samples. (c) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:59 / 65
页数:7
相关论文
共 48 条
  • [1] A high-throughput approach for the determination of pesticide residues in cucumber samples using solid-phase microextraction on 96-well plate
    Bagheri, Habib
    Es'haghi, Ali
    Es-haghi, Ali
    Mesbahi, Noushin
    ANALYTICA CHIMICA ACTA, 2012, 740 : 36 - 42
  • [2] High Throughput Liquid Chromatography/Mass Spectrometry Bioanalysis Using 96-Well Disk Solid Phase Extraction Plate for the Sample Preparation
    Simpson, H.
    Berthemy, A.
    Buhrman, D.
    Burton, R.
    Rapid Communications in Mass Spectrometry, 12 (02):
  • [3] High throughput liquid chromatography mass spectrometry bioanalysis using 96-well disk solid phase extraction plate for the sample preparation
    Simpson, H
    Berthemy, A
    Buhrman, D
    Burton, R
    Newton, J
    Kealy, M
    Wells, D
    Wu, DL
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1998, 12 (02) : 75 - 82
  • [4] High-throughput 96-well solid-phase extraction for preparation of tetracycline followed by liquid chromatography and mass spectrometry analysis
    Chen, Kang
    Wang, Jie
    Li, Shiyan
    Wang, Yang
    Zhang, Yiqi
    Shen, Qing
    ELECTROPHORESIS, 2019, 40 (04) : 555 - 562
  • [5] Evaluation of antibacterial activity of Australian basidiomycetous macrofungi using a high-throughput 96-well plate assay
    Bala, Neeraj
    Aitken, Elizabeth A. B.
    Fechner, Nigel
    Cusack, Andrew
    Steadman, Kathryn J.
    PHARMACEUTICAL BIOLOGY, 2011, 49 (05) : 492 - 500
  • [6] Towards high throughput analysis using 96-well plate solid phase extraction to determine sedatives and R-blocker residues in food control monitoring
    Arrizabalaga-Larranaga, Ane
    van Doorn, Dieke
    Sterk, Saskia S.
    ANALYTICA CHIMICA ACTA, 2024, 1331
  • [7] A high-throughput nanofibers mat-based micro-solid phase extraction for the determination of cationic dyes in wastewater
    Qi, Feifei
    Qian, Liangliang
    Liu, Jingjing
    Li, Xiaoqing
    Lu, Lingeng
    Xu, Qian
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1460 : 24 - 32
  • [8] High-throughput 96-well solvent mediated sonic blending synthesis and on-plate solid/solution stability characterization of pharmaceutical cocrystals
    Van Luu
    Jona, Janan
    Stanton, Mary K.
    Peterson, Matthew L.
    Morrison, Henry G.
    Nagapudi, Karthik
    Tan, Helming
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2013, 441 (1-2) : 356 - 364
  • [9] Automated solid-phase extraction of atenolol from human urine for high throughput LC-MS-MS analysis using a strata™-X 96-well plate
    Huq, Shahana Wahab
    Kallury, Krishna
    LC GC NORTH AMERICA, 2007, : 62 - 62
  • [10] An integrated platform for a high-throughput pharmacokinetic study of glycosides using a boronic acid-functionalized 96-well glass plate
    Zhao, Ningning
    Gu, Qianqian
    Liu, Zhiqiang
    Song, Fengrui
    Pi, Zifeng
    Liu, Shu
    CHEMICAL COMMUNICATIONS, 2019, 55 (64) : 9543 - 9546