Visualization of conductive spinal cord activity using a biomagnetometer

被引:30
作者
Kawabata, S [1 ]
Komori, H [1 ]
Mochida, K [1 ]
Harunobu, O [1 ]
Shinomiya, K [1 ]
机构
[1] Tokyo Med & Dent Univ, Dept Frontier Surg Therapeut, Div Adv Therapeut Sci, sect Orthopaed Spinal Surg,Bunkyo Ku, Tokyo 1138519, Japan
关键词
spinal cord evoked magnetic field; spinal cord evoked potential; biomagnetometer;
D O I
10.1097/00007632-200203010-00007
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. The authors measured conductive cervical spinal cord evoked magnetic fields (SCEFs) after thoracic spinal cord stimulation in cats and visualized spinal cord activities. Objective. To evaluate the usefulness of magnetic field measurement. Summary of Background Data. Magnetic field measurement has several theoretical advantages compared with electric potential measurement. Although biomagnetometers for the brain and heart are already on the market and are widely used, methods for magnetic field measurement of the spinal cord have not been established. Method. Cervical laminectomy was performed on adult cats under anesthesia and the dural tube was exposed. Electrical stimuli were applied to the lower thoracic spinal cord by a catheter epidural electrode. SCEFs were recorded using a biomagnetometer specially designed for recording spinal cord action potentials. SCEFs were measured at 35 different points over the cervical spine and isomagnetic field maps of SCEFs were constructed. Thereafter, the spinal cord was transected completely at C5 and SCEFs were measured again. Results. The detected SCEFs showed a clear biphasic configuration. The first deflection of the magnetic fields from the left side was directed outward, but the right-side deflection was directed inward. The second deflection showed reversed polarity. The isomagnetic field maps of SCEFs clearly demonstrated the quadrupolar pattern and propagated at a conduction velocity of 80-120 m/s. After spinal cord transection, the propagation of SCEFs stopped at the transection site, and the SCEFs could not be obtained above the site. Conclusions. The authors concluded that magnetic field measurement is useful for evaluation of spinal cord function. Moreover, it was apparent that SCEFs could indicate conduction block in the spinal cord.
引用
收藏
页码:475 / 479
页数:5
相关论文
共 15 条
[1]   SPINAL EVOKED-POTENTIAL IN CAT - EFFECTS OF ASPHYXIA, STRYCHNINE, CORD SECTION AND COMPRESSION [J].
CRACCO, RQ ;
EVANS, B .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1978, 44 (02) :187-201
[2]   Magnetometry of evoked fields from human peripheral nerve, brachial plexus and primary somatosensory cortex using a liquid nitrogen cooled superconducting quantum interference device [J].
Curio, G ;
Drung, D ;
Koch, H ;
Muller, W ;
Steinhoff, U ;
Trahms, L ;
Shen, YQ ;
Vase, P ;
Freltoft, T .
NEUROSCIENCE LETTERS, 1996, 206 (2-3) :204-206
[3]  
CURIO G, 1991, ELECTROEN CLIN NEURO, V81, P450, DOI 10.1016/0168-5597(91)90054-2
[4]   COMPARISON OF HUMAN EVOKED ELECTROSPINOGRAM RECORDED FROM INTRATHECAL, EPIDURAL AND CUTANEOUS LEVELS [J].
ERTEKIN, C .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1978, 44 (06) :683-690
[5]   SPINAL-CORD POTENTIALS-EVOKED BY PERIPHERAL-NERVE STIMULATION [J].
HAPPEL, LT ;
LEBLANC, HJ ;
KLINE, DG .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1975, 38 (04) :349-354
[6]   VISUALIZATION OF A MOVING QUADRUPOLE WITH MAGNETIC MEASUREMENTS OF PERIPHERAL-NERVE ACTION FIELDS [J].
HASHIMOTO, I ;
MASHIKO, T ;
MIZUTA, T ;
IMADA, T ;
IWASE, K ;
OKAZAKI, H .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1994, 93 (06) :459-467
[7]   Peripheral nerve conduction recorded by a micro gradiometer system (micro-SQUID) in humans [J].
Hoshiyama, M ;
Kakigi, R ;
Nagata, O .
NEUROSCIENCE LETTERS, 1999, 272 (03) :199-202
[8]   Whole-head SQUID system in a superconducting magnetic shield [J].
Ohta, H ;
Matsui, T .
PHYSICA C, 2000, 341 :2713-2714
[9]   Experimental analysis of distortion of magnetoencephalography signals by the skull [J].
Okada, YC ;
Lahteenmäki, A ;
Xu, CB .
CLINICAL NEUROPHYSIOLOGY, 1999, 110 (02) :230-238
[10]   ORIGIN OF SOMATOSENSORY EVOKED-RESPONSES RECORDED FROM CERVICAL SKIN SURFACE [J].
SHIMOJI, K ;
SHIMIZU, H ;
MARUYAMA, Y .
JOURNAL OF NEUROSURGERY, 1978, 48 (06) :980-984