Beam characterisation of the 1.5 T MRI-linac

被引:63
作者
Woodings, S. J. [1 ]
Bluemink, J. J. [1 ]
de Vries, J. H. W. [1 ]
Niatsetski, Y. [2 ]
van Veelen, B. [2 ]
Schillings, J. [2 ]
Kok, J. G. M. [1 ]
Wolthaus, J. W. H. [1 ]
Hackett, S. L. [1 ]
van Asselen, B. [1 ]
van Zijp, H. M. [1 ]
Pencea, S. [2 ]
Roberts, D. A. [2 ]
Lagendijk, J. J. W. [1 ]
Raaymakers, B. W. [1 ]
机构
[1] Univ Med Ctr Utrecht, Dept Radiotherapy, Heidelberglaan 100, NL-3584 CX Utrecht, Netherlands
[2] Elekta AB, Stockholm, Sweden
关键词
radiotherapy; MRI-linac; dosimetry; unity; beam characterisation; commissioning; MAGNETIC-FIELD CORRECTION; REFERENCE DOSIMETRY; IONIZATION-CHAMBER; MONTE-CARLO; RADIOTHERAPY; ACCELERATOR; PHANTOM; IMPACT; PHOTON;
D O I
10.1088/1361-6560/aab566
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
As a prerequisite for clinical treatments it was necessary to characterize the Elekta 1.5 T MRI-linac 7 MV FFF radiation beam. Following acceptance testing, beam characterization data were acquired with Semiflex 3D (PTW 31021), microDiamond ( PTW 60019), and Farmer-type ( PTW 30013 and IBA FC65-G) detectors in an Elekta 3D scanning water phantom and a PTW 1D water phantom. EBT3 Gafchromic film and ion chamber measurements in a buildup cap were also used. Special consideration was given to scan offsets, detector effective points of measurement and avoiding air gaps. Machine performance has been verified and the system satisfied the relevant beam requirements of IEC60976. Beam data were acquired for field sizes between 1 x 1 and 57 x 22 cm(2). New techniques were developed to measure percentage depth dose (PDD) curves including the electron return effect at beam exit, which exhibits an electron-type practical range of 1.2 +/- 0.1 cm. The Lorentz force acting on the secondary charged particles creates an asymmetry in the crossline profiles with an average shift of +0.24 cm. For a 10 x 10 cm2 beam, scatter from the cryostat contributes 1% of the dose at isocentre. This affects the relative output factors, scatter factors and beam profiles, both in-field and out-of-field. The average 20%-80% penumbral width measured for small fields with a microDiamond detector at 10 cm depth is 0.50 cm. MRI-linac penumbral widths are very similar to that of the Elekta Agility linac MLC, as is the near-surface dose PDD(0.2 cm) = 57%. The entrance surface dose is similar to 36% of D-max. Cryostat transmission is quantified for inclusion within the treatment planning system. As a result, the 1.5 T MRI-linac 7 MV FFF beam has been characterised for the first time and is suitable for clinical use. This was a key step towards the first clinical treatments with the MRI-linac, which were delivered at University Medical Center Utrecht in May 2017.
引用
收藏
页数:12
相关论文
共 30 条
[1]   AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams [J].
Almond, PR ;
Biggs, PJ ;
Coursey, BM ;
Hanson, WF ;
Huq, MS ;
Nath, R ;
Rogers, DWO .
MEDICAL PHYSICS, 1999, 26 (09) :1847-1870
[2]  
Andreo P., 2006, IAEA TECH REP SER, p140
[3]   IPEM topical report 1: guidance on implementing flattening filter free (FFF) radiotherapy [J].
Budgell, Geoff ;
Brown, Kirstie ;
Cashmore, Jason ;
Duane, Simon ;
Frame, John ;
Hardy, Mark ;
Paynter, David ;
Thomas, Russell .
PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (23) :8360-8394
[4]  
de Prez L, 2016, AAPM 2016 ANN C
[5]  
Duglio M, 2016, AAPM 2016 ANN C
[6]   Definition of parameters for quality assurance of flattening filter free (FFF) photon beams in radiation therapy [J].
Fogliata, A. ;
Garcia, R. ;
Knoos, T. ;
Nicolini, G. ;
Clivio, A. ;
Vanetti, E. ;
Khamphan, C. ;
Cozzi, L. .
MEDICAL PHYSICS, 2012, 39 (10) :6455-6464
[7]   Impact of air around an ion chamber: solid water phantoms not suitable for dosimetry on an MR-linac [J].
Hackett, S. ;
Van Asselen, B. ;
Wolthaus, J. ;
Kok, J. ;
Woodings, S. ;
Lagendijk, J. ;
Raaymakers, B. .
RADIOTHERAPY AND ONCOLOGY, 2016, 119 :S34-S35
[8]  
International Electrotechnical Commission, 2011, IEC 61217
[9]  
International Electrotechnical Commission, 2007, IEC 60976 Medical electrical equipment-Medical electron accelerators-functional performance characteristics, 2007 describes the tests to be performed
[10]  
Khan F.M., 2003, PHYS RAD THERAPY