A comparison of two direct-reading aerosol monitors with the federal reference method for PM2.5 in indoor air

被引:144
作者
Yanosky, JD [1 ]
Williams, PL [1 ]
MacIntosh, DL [1 ]
机构
[1] Univ Georgia, Dept Environm Hlth Sci, Athens, GA 30602 USA
关键词
aerosol sampling; particulate matter; aerodynamic particle sizer; DustTrak Aerosol Monitor; Federal Reference Method;
D O I
10.1016/S1352-2310(01)00422-8
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Two types of direct-reading aerosol monitoring devices, the TSI, Inc. Model 3320 Aerodynamic Particle Sizer (APS), and the TSI Inc. Model 8520 DustTrak Aerosol Monitor (DustTrak), were collocated indoors with a US EPA designated Federal Reference Method (FRM) PM2.5, sampler, the BGI, Inc. PQ200, to assess the comparability of the sampling methods. Simultaneous 24-h samples were collected from two APS instruments, one DustTrak and one FRM sampler for 20 sample periods. The 30-min average concentrations during the 24-hour sample periods were also logged and compared for the APS and DustTrak. Statistical analysis on the mass concentrations obtained from each sampler type included paired t-tests and linear regression. The 24-h average PM2.5 levels from the FRM samplers were approximately normally distributed and ranged from 5.0 to 20.4mug m(-3) with mean and standard deviation 11.4 and 4.0 mug m(-3), respectively. The 24-h average DustTrak levels are well correlated with FRM levels (R-2 = 0.859) but show significant proportional bias (beta(1) = 2.57, p<0.0001). The 24-h average mean collocated APS levels are less highly correlated with the FRM (R-2 = 0.592) and do not show statistically significant proportional bias. The 30-min average levels between the two APS instruments show a high correlation (R-2 = 0.979) but significant proportional bias (β(1) = 1.31, p&LT;0.0001). The results suggest that though the DustTrak provides precise measurements of PM2.5, the accuracy of the measurements compared to the FRM can be improved through statistical adjustment. In contrast, APS PM2.5 measurements are less precise and less accurate compared to the FRM and therefore results from the APS should be interpreted with caution. © 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:107 / 113
页数:7
相关论文
共 14 条
[1]   Characterization of indoor particle sources: A study conducted in the metropolitan Boston area [J].
Abt, E ;
Suh, HH ;
Allen, G ;
Koutrakis, P .
ENVIRONMENTAL HEALTH PERSPECTIVES, 2000, 108 (01) :35-44
[2]   PERSONAL EXPOSURES TO ACIDIC AEROSOLS AND GASES [J].
BRAUER, M ;
KOUTRAKIS, P ;
SPENGLER, JD .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1989, 23 (11) :1408-1412
[3]   Sampling efficiency of the TSI Aerodynamic Particle Sizer [J].
Chen, YC ;
Barber, EM ;
Zhang, YH .
INSTRUMENTATION SCIENCE & TECHNOLOGY, 1998, 26 (04) :363-373
[4]   Comparison of real-time instruments used to monitor airborne particulate matter [J].
Chung, A ;
Chang, DPY ;
Kleeman, MJ ;
Perry, KD ;
Cahill, TA ;
Dutcher, D ;
McDougall, EM ;
Stroud, K .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2001, 51 (01) :109-120
[5]   Fine particle (PM2.5) measurement methodology, quality assurance procedures, and pilot results of the EXPOLIS study [J].
Koistinen, KJ ;
Kousa, A ;
Tenhola, V ;
Hänninen, O ;
Jantunen, MJ ;
Oglesby, L ;
Kuenzli, N ;
Georgoulis, L .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1999, 49 (10) :1212-1220
[6]   Effects of ozone and other pollutants on the pulmonary function of adult hikers [J].
Korrick, SA ;
Neas, LM ;
Dockery, DW ;
Gold, DR ;
Allen, GA ;
Hill, LB ;
Kimball, KD ;
Rosner, BA ;
Speizer, FE .
ENVIRONMENTAL HEALTH PERSPECTIVES, 1998, 106 (02) :93-99
[7]   Comparison of respirable samplers to direct-reading real time aerosol monitors for measuring coal dust [J].
Lehocky, AH ;
Williams, PL .
AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1996, 57 (11) :1013-1018
[8]   A case-crossover analysis of air pollution and mortality in Philadelphia [J].
Neas, LM ;
Schwartz, J ;
Dockery, D .
ENVIRONMENTAL HEALTH PERSPECTIVES, 1999, 107 (08) :629-631
[9]   Air pollution and incidence of cardiac arrhythmia [J].
Peters, A ;
Liu, E ;
Verrier, RL ;
Schwartz, J ;
Gold, DR ;
Mittleman, M ;
Baliff, J ;
Oh, JA ;
Allen, G ;
Monahan, K ;
Dockery, DW .
EPIDEMIOLOGY, 2000, 11 (01) :11-17
[10]   Comparison of short-term variations (15-minute averages) in outdoor and indoor PM2.5 concentrations [J].
Ramachandran, G ;
Adgate, JL ;
Hill, N ;
Sexton, K ;
Pratt, GC ;
Bock, D .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2000, 50 (07) :1157-1166