Tuning preparation conditions towards optimized separation performance of thermally polymerized organo-silica monolithic columns in capillary liquid chromatography

被引:13
作者
Gharbharan, Deepa [1 ]
Britsch, Denae [1 ]
Soto, Gabriela [1 ]
Weed, Anna-Marie Karen [1 ]
Svec, Frantisek [2 ]
Zajickova, Zuzana [1 ]
机构
[1] Barry Univ, Dept Phys Sci, Miami Shores, FL 33161 USA
[2] EO Lawrence Berkeley Natl Lab, Mol Foundry, Berkeley, CA 94720 USA
基金
美国国家科学基金会;
关键词
Organo-silica; Hybrid; Monolith; Sol-gel; Photo-polymerization; Thermal polymerization; SOL-GEL MONOLITHS; HIGH-EFFICIENCY; ELECTROCHROMATOGRAPHY; BEHAVIOR;
D O I
10.1016/j.chroma.2015.06.069
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Tuning of preparation conditions, such as variations in the amount of a porogen, concentration of an aqueous acid catalyst, and adjustment in polymerization temperature and time, towards optimized chromatographic performance of thermally polymerized monolithic capillaries prepared from 3-(methacryloyloxy)propyltrimethoxysilane has been carried out. Performance of capillary columns in reversed-phase liquid chromatography was assessed utilizing various sets of solutes. Results describing hydrophobicity, steric selectivity, and extent of hydrogen bonding enabled comparison of performance of hybrid monolithic columns prepared under thermal (TSG) and photopolymerized (PSG) conditions. Reduced amounts of porogen in the polymerization mixture, and prolonged reaction times were necessary for the preparation of monolithic columns with enhanced retention and column efficiency that reached to 111,000 plates/m for alkylbenzenes with shorter alkyl chains. Both increased concentration of catalyst and higher temperature resulted in faster polymerization but inevitably in insufficient time for pore formation. Thermally polymerized monoliths produced surfaces, which were slightly more hydrophobic (a methylene selectivity of 1.28 +/- 10.002 TSG vs 1.20 +/- 0.002 PSG), with reduced number of residual silanols (a caffeine/phenol selectivity of 0.13 +/- 10.001 TSG vs 0.17 +/- 0.003 PSG). However, steric selectivity of 1.70 +/- 1 0.01 was the same for both types of columns. The batch-to-batch repeatability was better using thermal initiation compared to monolithic columns prepared under photopolymerized conditions. RSD for retention factor of benzene was 3.7% for TSG capillaries (n = 42) vs. 6.6% for PSG capillaries (n = 18). A similar trend was observed for columns prepared within the same batch. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:101 / 107
页数:7
相关论文
共 25 条
[1]  
Bersani D, 1999, J RAMAN SPECTROSC, V30, P1043, DOI 10.1002/(SICI)1097-4555(199911)30:11<1043::AID-JRS480>3.0.CO
[2]  
2-Q
[3]  
Cabrera K, 2000, HRC-J HIGH RES CHROM, V23, P93
[4]   Allyl-functionalized hybrid silica monoliths [J].
Colón, H ;
Zhang, X ;
Murphy, JK ;
Rivera, JG ;
Colón, LA .
CHEMICAL COMMUNICATIONS, 2005, (22) :2826-2828
[5]  
Dulay MT, 2002, J SEP SCI, V25, P3, DOI 10.1002/1615-9314(20020101)25:1/2<3::AID-JSSC3>3.3.CO
[6]  
2-C
[7]   Photopolymerized sol-gel monoliths for capillary electrochromatography [J].
Dulay, MT ;
Quirino, JP ;
Bennett, BD ;
Kato, M ;
Zare, RN .
ANALYTICAL CHEMISTRY, 2001, 73 (16) :3921-3926
[8]   Comparison of the chromatographic behavior of monolithic capillary columns in capillary electrochromatography and nano-high-performance liquid chromatography [J].
Freitag, R .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1033 (02) :267-273
[9]   Monolithic columns in high-performance liquid chromatography [J].
Guiochon, Georges .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1168 (1-2) :101-168
[10]   Monolithic columns for high-efficiency HPLC separations [J].
Ikegami, T ;
Tanaka, N .
CURRENT OPINION IN CHEMICAL BIOLOGY, 2004, 8 (05) :527-533