The impact of green facades and vegetative cover on the temperature and relative humidity within model buildings

被引:26
作者
Thomsit-Ireland, Faye [1 ]
Essah, Emmanuel A. [1 ]
Hadley, Paul [3 ]
Blanusa, Tijana [2 ,3 ]
机构
[1] Univ Reading, Sch Built Environm, Reading RG6 6DF, Berks, England
[2] Royal Hort Soc, Sci Dept, RHS Garden Wisley, Woking GU23 6QB, GU, England
[3] Univ Reading, Sch Agr Policy & Dev, Reading RG6 6AS, Berks, England
基金
英国工程与自然科学研究理事会;
关键词
Cooling; Damp; Green walls; Insulation; Ivy; Relative humidity; THERMAL-BEHAVIOR; WINTER; WALLS; PERFORMANCE;
D O I
10.1016/j.buildenv.2020.107009
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Vertical greening solutions such as direct greening are gaining popularity due to their relatively low cost and minimal ground footprint. However, concerns about increases in relative humidity (RH) can reduce implementation. The impact of several widely-used plant species (Hedera helix, Parthenocissus tricuspidata and Pileostegia viburnoides) on the internal/external temperature and RH on the south-facing wall of replicated experimental model 'buildings' was studied during summer and winter. All plant species reduced the air temperature internally/externally during the summer daytimes by at least 1 degrees C compared to bare 'buildings'. Hedera produced the greatest cooling effect internally and externally, by 7.2 degrees C and 5.7 degrees C respectively. All plant species reduced daily variation in external RH and external/internal temperature during summer; Hedera reduced variation most and Pileostegia least. During night-time in both seasons, the temperature behind Hedera foliage typically remained higher, which could reduce the risk of freeze-thaw damage in winter. The RH was not significantly elevated by vegetation except during warm afternoons in summer and winter. During warm afternoons, the external RH was significantly higher only behind the Hedera foliage compared to the bare `buildings', 11% and 3.7%, summer and winter respectively. However, inside all vegetated `buildings' the RH was at least 11% higher compared to the bare `buildings' during summer. Yet, in winter the internal RH was 5.7% lower in the Hedera-covered compared to the bare 'buildings'. Current building standards would prevent the transfer of external RH in this range internally, as the walls include protective layers such as damppro of membranes.
引用
收藏
页数:11
相关论文
共 51 条
[1]  
[Anonymous], 1993, FASSADEN DACHBEGRUNU
[2]  
[Anonymous], 2017, Global Greenhouse Gas Emissions Data
[3]  
[Anonymous], 2008, CLIMATE CHANGE 2007
[4]  
ASHRAE, 2013, 6212013 ANSI ASHRAE
[5]   Effectiveness of an ivy covering at insulating a building against the cold in Manchester, U.K: A preliminary investigation [J].
Bolton, C. ;
Rahman, M. A. ;
Armson, D. ;
Ennos, A. R. .
BUILDING AND ENVIRONMENT, 2014, 80 :32-35
[6]  
BRE (Building Research Establishment) Construction Research Communications Ltd, 1996, CONDTR RES COMM LTD
[7]   A Hedera green facade - Energy performance and saving under different maritime-temperate, winter weather conditions [J].
Cameron, Ross W. F. ;
Taylor, Jane ;
Emmett, Martin .
BUILDING AND ENVIRONMENT, 2015, 92 :111-121
[8]   What's 'cool' in the world of green facades? How plant choice influences the cooling properties of green walls [J].
Cameron, Ross W. F. ;
Taylor, Jane E. ;
Emmett, Martin R. .
BUILDING AND ENVIRONMENT, 2014, 73 :198-207
[9]  
Cantuaria G.A.C., 2000, ARCHITECTURE CITY EN
[10]   Simulation assessment of living wall thermal performance in winter in the climate of Portugal [J].
Carlos, Jorge S. .
BUILDING SIMULATION, 2015, 8 (01) :3-11