Patient-specific organ and effective dose estimates in pediatric oncology computed tomography

被引:37
作者
Gao, Yiming [1 ]
Quinn, Brian [1 ]
Pandit-Taskar, Neeta [2 ]
Behr, Gerald [2 ]
Mahmood, Usman [1 ]
Long, Daniel [1 ]
Xu, X. George [3 ]
St.Germain, Jean [1 ]
Dauer, Lawrence T. [1 ,2 ]
机构
[1] Mem Sloan Kettering Canc Ctr, Dept Med Phys, 1275 York Ave, New York, NY 10065 USA
[2] Mem Sloan Kettering Canc Ctr, Dept Radiol, 1275 York Ave, New York, NY 10065 USA
[3] Rensselaer Polytech Inst, Dept Mech Aerosp & Nucl Engn, Troy, NY 12180 USA
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2018年 / 45卷
关键词
Pediatric; Computed tomography; Diagnostic reference level; Organ dose; TUBE-CURRENT MODULATION; CT EXAMINATIONS; CONVERSION COEFFICIENTS; IMAGE QUALITY; REDUCTION; PHANTOM; BREAST; ADULT;
D O I
10.1016/j.ejmp.2017.12.013
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Estimate organ and effective doses from computed tomography scans of pediatric oncologic patients using patient-specific information. Materials and Methods: With IRB approval patient-specific scan parameters and patient size obtained from DICOM images and vendor-provided dose monitoring application were obtained for a cross-sectional study of 1250 pediatric patients from 0 through 20 y-olds who underwent head, chest, abdomen-pelvis, or chest-abdomen-pelvis CT scans. Patients were categorized by age. Organ doses and effective doses were estimated using VirtualDose (TM) CT based on patient-specific information, tube current modulation (TCM), and age-specific realistic phantoms. CTDIvol, DLP, and dose results were compared with those reported in the literature. Results: CTDIvol and DLP varied widely as patient size varied. The 75th percentiles of CTDIvol and DLP were no greater than in the literature with the exception of head scans of 16-20 y-olds and of abdomen-pelvis scans of larger patients. Eye lens dose from a head scan was up to 69 mGy. Mean organ doses agreed with other studies at maximal difference of 38% for chest and 41% for abdomen-pelvis scans. Mean effective dose was generally higher for older patients. The highest effective doses were estimated for the 16-20 y-olds as: head 3.3 mSv, chest 4.1 mSv, abdomen-pelvis 10.0 mSv, chest-abdomen-pelvis 14.0 mSv. Conclusion: Patient-specific organ and effective doses have been estimated for pediatric oncologic patients from < 1 through 20 y-olds. The effect of TCM was successfully accounted for in the estimates. Output parameters varied with patient size. CTDIvol and DLP results are useful for future protocol optimization.
引用
收藏
页码:146 / 155
页数:10
相关论文
共 46 条
[1]  
aapm, AAPM Report 204
[2]  
AAPM, 2008, 96 AAPM
[3]  
AAPM TG 220, 2014, AAPM REP 220, V220, P1
[4]  
[Anonymous], 2003, Ann ICRP, V33, P1, DOI [10.1016/S0146-6453(03)00024-1, DOI 10.1016/S0146-6453(03)00024-1]
[5]  
[Anonymous], 2013, UNSCEAR 2013 Report
[6]   Image Gently: A Decade of International Collaborations to Promote Appropriate Imaging for Children [J].
Applegate, Kimberly E. ;
Frush, Donald P. .
JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2017, 14 (07) :956-957
[7]   Comparison of organ dosimetry methods and effective dose calculation methods for paediatric CT [J].
Brady, Z. ;
Cain, T. M. ;
Johnston, P. N. .
AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2012, 35 (02) :117-134
[8]   Current concepts - Computed tomography - An increasing source of radiation exposure [J].
Brenner, David J. ;
Hall, Eric J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) :2277-2284
[9]   ASSESSMENT OF ORGAN ABSORBED DOSES AND ESTIMATION OF EFFECTIVE DOSES FROM PEDIATRIC ANTHROPOMORPHIC PHANTOM MEASUREMENTS FOR MULTI-DETECTOR ROW CT WITH AND WITHOUT AUTOMATIC EXPOSURE CONTROL [J].
Brisse, Herve J. ;
Robilliard, Magalie ;
Savignoni, Alexia ;
Pierrat, Noelle ;
Gaboriaud, Genevieve ;
De Rycke, Yann ;
Neuenschwander, Sylvia ;
Aubert, Bernard ;
Rosenwald, Jean-Claude .
HEALTH PHYSICS, 2009, 97 (04) :303-314
[10]   VirtualDose: a software for reporting organ doses from CT for adult and pediatric patients [J].
Ding, Aiping ;
Gao, Yiming ;
Liu, Haikuan ;
Caracappa, Peter F. ;
Long, Daniel J. ;
Bolch, Wesley E. ;
Liu, Bob ;
Xu, X. George .
PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (14) :5601-5625