Serum Ion Levels after Ceramic-on-Ceramic and Metal-on-Metal Total Hip Arthroplasty: 8-Year Minimum Follow-up

被引:32
作者
Savarino, Lucia [1 ]
Padovanni, Giovanni [3 ]
Ferretti, Massimo [3 ]
Greco, Michelina [1 ]
Cenni, Elisabetta [1 ]
Perrone, Giorgio [3 ]
Greco, Francesco [3 ]
Baldini, Nicola [1 ,2 ]
Giunti, Armando [1 ,2 ]
机构
[1] Ist Ortoped Rizzoli, Lab Pathophysiol Orthopaed Implants, I-40136 Bologna, Italy
[2] Ist Ortoped Rizzoli, Div Orthopaed Surg 7, I-40136 Bologna, Italy
[3] Este Hosp, Orthoped & Traumatol Div, Padua, Italy
关键词
metal-on metal; ceramic-on-ceramic; alternative bearing; metal ions; arthroplasty;
D O I
10.1002/jor.20701
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Alternative bearing surface for total hip arthoplasty, such as metal-on-metal and ceramic-on-ceramic, offer the potential to reduce mechanical wear and osteolysis. In the short and medium term, the second generation of metal-on-metal bearings demonstrated high systemic metal ion levels. whereas ceramic-on-cerainic hearings showed the lowest ones. We aimed to verify whether the long-term ion release in metal-on-metal subjects was still relevant at a median 10-year follow-up, and whether a fretting process at the modular junctions occurred in ceramic-on-ceramic patients and induced an ion dissemination. Serum levels were measured in 32 patients with alumina-on-occured implants (group A), in 16 subjects with metal-on-metal implants (group B), and in 47 healthy subjects (group C). Group B results were compared with medium-term findings. Cobalt and chromium levels were significantly higher in metal-on-metal implants than in ceramic-on-cerainic ones and controls. Nevertheless, ion levels showed a tendency to decrease in comparison with medium-term content. In ceramic-on-ceramic implants, ion values were not significantly different from controls. Both in groups A and 13, aluminium and titanium release were not significantly different from controls. In conclusion, negligible serum metal ion content was revealed in ceramic-on-cerainic patients. On the contrary, due to the higher ion release, metal-on-metal coupling must be prudently considered, especially in young patients, in order to obtain definitive conclusions. (c) 2008 Orthopaedic Research Society. Published by Wiley Periodicals. Inc. J Orthop Res 26:1569-1576, 2008
引用
收藏
页码:1569 / 1576
页数:8
相关论文
共 56 条
[1]   TREATMENT OF PRIMARY OSTEOARTHRITIS OF THE HIP - A COMPARISON OF TOTAL JOINT AND SURFACE REPLACEMENT ARTHROPLASTY [J].
AMSTUTZ, HC ;
THOMAS, BJ ;
JINNAH, R ;
KIM, W ;
GROGAN, T ;
YALE, C .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1984, 66A (02) :228-241
[2]   The wear pattern in metal-on-metal hip prostheses [J].
Anissian, HL ;
Stark, A ;
Good, V ;
Dahlstrand, H ;
Clarke, IC .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2001, 58 (06) :673-678
[3]  
Archibeck M J, 2001, Instr Course Lect, V50, P185
[4]  
Archibeck MJ, 2000, CLIN ORTHOP RELAT R, P12
[5]   Concerns about ceramics in THA [J].
Barrack, RL ;
Barak, C ;
Skinner, HB .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (429) :73-79
[6]  
Bizot P, 2001, CLIN ORTHOP RELAT R, P85
[7]  
BRIEN WW, 1990, T ORTHOP RES SOC, V15, P27
[8]   Serum cobalt levels after metal-on-metal total hip arthroplasty [J].
Brodner, W ;
Bitzan, P ;
Meisinger, V ;
Kaider, A ;
Gottsauner-Wolf, F ;
Kotz, R .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (11) :2168-2173
[9]   Elevated serum cobalt with metal-on-metal articulating surfaces [J].
Brodner, W ;
Bitzan, P ;
Meisinger, V ;
Kaider, A ;
GottsaunerWolf, F ;
Kotz, R .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1997, 79B (02) :316-321
[10]  
Doorn PF, 1996, CLIN ORTHOP RELAT R, pS187