Flow optimization in one-dimensional and comprehensive two-dimensional gas chromatography

被引:12
作者
Blumberg, Leonid M. [1 ]
机构
[1] Advachrom, POB 1243, Wilmington, DE 19801 USA
关键词
Efficiency-optimized flow rate (EOF); Speed-optimized flow rate (SOF); Default flow rate; Flow reconciliation in GC x GC; PLATE HEIGHT; SEPARATION PERFORMANCE; METHOD-TRANSLATION; MASS-SPECTROMETRY; LIQUID-CHROMATOGRAPHY; COLUMN PERFORMANCE; CONSTANT-PRESSURE; KINETIC PLOTS; CAPILLARY GC; HEATING RATE;
D O I
10.1016/j.chroma.2017.08.040
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Theoretical considerations of optimal flow in a GC column under different conditions are outlined from a single perspective, and numerical recommendations are provided. The optimal flow rate in a temperature programmed column is about 30% lower than its isothermal counterpart in the same column with the same carrier gas. A simplified calculation of recommended optimal or near optimal flow rate in a single column under different conditions is summarized in a single equation. In GC x GC, the primary column operates under temperature-programmed conditions while each secondary run is essentially isothermal. As a result, their flow optimization requirements are different. The complementary IDs (internal diameters) corresponding to equal optimal flow rates in both GC x GC columns should relate as (2)d = 0.7(.1)d. Typical complementary ID pairs are tabulated. If choosing the complementary IDs is not an option, several ways to reconcile the difference in their optimal flow rates are considered. The most typical cases of the column mismatch are identified and their boundary conditions are formulated. The effect of the flow reconciliation in these column pairs on the performance of GC x GC analysis is evaluated. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:27 / 38
页数:12
相关论文
共 62 条
[1]   Development of fast enantioselective gas-chromatographic analysis using gas-chromatographic method-translation software in routine essential oil analysis (lavender essential oil) [J].
Bicchi, Carlo ;
Blumberg, Leonid ;
Cagliero, Cecilia ;
Cordero, Chiara ;
Rubiolo, Patrizia ;
Liberto, Erica .
JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (09) :1530-1536
[2]  
Blumberg L., 2011, Comprehensive Chromatography in Combination with Mass Spectrometry, P13, DOI DOI 10.1002/9781118003466.CH2
[3]  
Blumberg L. M., 2013, UNPUB
[4]  
Blumberg L.M., 2012, GAS CHROMATOGRAPHY, P19
[5]  
Blumberg L.M., 1997, J HIGH RES CHROMATOG, V20, P597, DOI DOI 10.1002/JHRC.1240201106
[6]   Comparison of one-dimensional and comprehensive two-dimensional separations by gas chromatography [J].
Blumberg, Leonid M. ;
David, Frank ;
Klee, Matthew S. ;
Sandra, Pat .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1188 (01) :2-16
[7]   Distribution-centric 3-parameter thermodynamic models of partition gas chromatography [J].
Blumberg, Leonid M. .
JOURNAL OF CHROMATOGRAPHY A, 2017, 1491 :159-170
[8]   Metrics of separation performance in chromatography Part 3: General separation performance of linear solvent strength gradient liquid chromatography [J].
Blumberg, Leonid M. ;
Desmet, Gert .
JOURNAL OF CHROMATOGRAPHY A, 2015, 1413 :9-21
[9]   Metrics of separation performance in chromatography: Part 2. Separation performance of a heating ramp in temperature-programmed gas chromatography [J].
Blumberg, Leonid M. .
JOURNAL OF CHROMATOGRAPHY A, 2012, 1244 :148-160
[10]   Plate height formula widely accepted in GC is not correct [J].
Blumberg, Leonid M. .
JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (48) :8722-8723