Reliability of transcutaneous oximeter electrode heating power during exercise in patients with intermittent claudication

被引:44
作者
Gardner, AW [1 ]
机构
[1] UNIV MARYLAND, DEPT MED, CLAUDE D PEPPER OLDER AMER INDEPENDENCE CTR, DIV GERONTOL, BALTIMORE, MD 21201 USA
关键词
D O I
10.1177/000331979704800305
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
The purposes of this study were to (1) compare the reliability of transcutaneous oximeter electrode power with the reliability of oxygen tension and (2) compare the relationship of the oximetry measures with exercise performance in claudicants. One hundred ten PAOD patients with stable claudication symptoms performed a treadmill test and had the following exercise measures obtained: foot transcutaneous oxygen tension, oximeter electrode heating power, exercise duration, and peak oxygen consumption. A subset of 30 patients were tested once per week over three successive weeks to assess the reliability of the oximetry measures. The coefficient of variation of foot transcutaneous oxygen tension at peak exercise was 32.8%, whereas the variability of the oximeter electrode heating power was only 5.1%. Oximeter electrode heating power at peak exercise was related to maximal claudication pain time (r=0.44, P < 0.001) and peak oxygen consumption (r=0.36, P < 0.001), whereas foot transcutaneous oxygen tension was not related to either (r=0.15, P=0.119; r=0.13, P=0.189; respectively). Thus, transcutaneous oximeter electrode heating power was six to seven times less variable than transcutaneous oxygen tension, and the oximeter electrode power at peak exercise was more closely related to exercise capacity. It ss concluded that the measurement of transcutaneous oximeter electrode heating power during exercise is more reliable and better correlated with exercise capacity in PAOD patients with intermittent claudication than the measurement of transcutaneous oxygen tension.
引用
收藏
页码:229 / 235
页数:7
相关论文
共 19 条
  • [1] *AM COLL SPORTS ME, 1991, GUID EX TEST PRESCR, P167
  • [2] THE USE OF TRANS-CUTANEOUS OXYGEN-TENSION MEASUREMENTS IN THE DIAGNOSIS OF PERIPHERAL VASCULAR INSUFFICIENCY
    BYRNE, P
    PROVAN, JL
    AMELI, FM
    JONES, DP
    [J]. ANNALS OF SURGERY, 1984, 200 (02) : 159 - 165
  • [3] UTILITY OF TRANS-CUTANEOUS OXYGEN-TENSION MEASUREMENTS IN PERIPHERAL ARTERIAL OCCLUSIVE DISEASE
    CINA, C
    KATSAMOURIS, A
    MEGERMAN, J
    BREWSTER, DC
    STRAYHORN, EC
    ROBISON, JG
    ABBOTT, WM
    [J]. JOURNAL OF VASCULAR SURGERY, 1984, 1 (02) : 362 - 371
  • [4] CLYNE CAC, 1979, SURG GYNECOL OBSTET, V149, P727
  • [5] CORRELATION OF TRANS-CUTANEOUS OXYGEN-TENSION TO BLOOD-FLOW IN HEATED SKIN
    EICKHOFF, JH
    JACOBSEN, E
    [J]. SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1980, 40 (08) : 761 - 765
  • [6] CLAUDICATION PAIN AND HEMODYNAMIC-RESPONSES TO EXERCISE IN YOUNGER AND OLDER PERIPHERAL ARTERIAL-DISEASE PATIENTS
    GARDNER, AW
    [J]. JOURNALS OF GERONTOLOGY, 1993, 48 (05): : M231 - M236
  • [7] RELATIONSHIP BETWEEN FOOT TRANSCUTANEOUS OXYGEN-TENSION AND ANKLE SYSTOLIC BLOOD-PRESSURE AT REST AND FOLLOWING EXERCISE
    GARDNER, AW
    SKINNER, JS
    CANTWELL, BW
    SMITH, LK
    DIETHRICH, EB
    [J]. ANGIOLOGY, 1991, 42 (06) : 481 - 490
  • [8] GARDNER AW, 1991, MED SCI SPORT EXER, V23, P402
  • [9] EFFECTS OF HANDRAIL SUPPORT ON CLAUDICATION AND HEMODYNAMIC-RESPONSES TO SINGLE-STAGE AND PROGRESSIVE TREADMILL PROTOCOLS IN PERIPHERAL VASCULAR OCCLUSIVE DISEASE
    GARDNER, AW
    SKINNER, JS
    SMITH, LK
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1991, 68 (01) : 99 - 105
  • [10] ANTIHISTAMINES REDUCE BLOOD-RETINAL BARRIER PERMEABILITY IN TYPE-I (INSULIN-DEPENDENT) DIABETIC-PATIENTS WITH NONPROLIFERATIVE RETINOPATHY - A PILOT-STUDY
    GARDNER, TW
    ELLER, AW
    FRIBERG, TR
    DANTONIO, JA
    HOLLIS, TM
    [J]. RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 1995, 15 (02): : 134 - 140