Effect of channel aspect ratio of 3-D T-mixer on flow patterns and convective mixing for a wide range of Reynolds number

被引:31
作者
Cortes-Quiroz, C. A. [1 ,2 ]
Azarbadegan, A. [2 ]
Zangeneh, M. [2 ]
机构
[1] UCL, Dept Biochem Engn, Bernard Katz Bldg,Gordon St, London WC1E 6BT, England
[2] UCL, Dept Mech Engn, Torrington Pl, London WC1E 7JE, England
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2017年 / 239卷
关键词
Microfluidics; Convective mixing; 3-D T-mixer; Channel aspect ratio; Vortical flow; Process intensification; TOTAL ANALYSIS SYSTEMS; MICRO; MICROCHANNELS; MICROMIXERS; TECHNOLOGY; REGIMES; MEMS;
D O I
10.1016/j.snb.2016.08.116
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The 3-D T-mixer is so called because of the three-dimensional structure of the T-junction formed by locating the inlet channels at different horizontal levels [1]. It has been found to exert a strong influence on the characteristics of flow from the T-junction downstream in the mixing channel, with Reynolds number (Re) higher than 50. A comparison of the 3-D T-mixer with the typical T-mixer working under the same operating conditions, i.e., with equal Re in the mixing channel, demonstrated that the former presents design advantages as it gave a higher degree of mixing with lower pressure loss and similar level of shear stress [2]. In this paper, a numerical parametric study using Computational Fluid Dynamics (CFD) has been made on the basis of the original 3-D T-mixer to identify the design configuration that enhances mixing more quickly in the Re range of 50-700. The height (H) and the width (W) of the mixing channel were used as geometric parameters, which were varied independently to generate geometric configurations that differ in the aspect ratio (H/VV) and the relative positions between the inlet channels. The configurations that gave higher mixing index in 2 mm channel length were studied more in detail. It was found that the variation of the width of the mixing channel resulted in design configurations wherein the flow became unsteady for some Re values and a quick increase of mixing index was achieved in the Re interval of 50-150. Experiments using fluorescent dyes showed a good correspondence to the numerical simulation outcomes. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:1153 / 1176
页数:24
相关论文
共 41 条
  • [1] Flow regimes in T-shaped micro-mixers
    Andreussi, Tommaso
    Galletti, Chiara
    Mauri, Roberto
    Camarri, Simone
    Salvetti, Maria Vittoria
    [J]. COMPUTERS & CHEMICAL ENGINEERING, 2015, 76 : 150 - 159
  • [2] Vortex micro T-mixer with non-aligned inputs
    Ansari, Mubashshir A.
    Kim, Kwang-Yong
    Anwar, Khalid
    Kim, Sun Min
    [J]. CHEMICAL ENGINEERING JOURNAL, 2012, 181 : 846 - 850
  • [3] Ansys, 2007, CFX 11 0 US MAN
  • [4] Ansys, 2007, ICEM 11 0 US MAN
  • [5] Fluid mixing in a T-shaped micro-mixer
    Bothe, D
    Sternich, C
    Warnecke, HJ
    [J]. CHEMICAL ENGINEERING SCIENCE, 2006, 61 (09) : 2950 - 2958
  • [6] Fully resolved numerical simulation of reactive mixing in a T-shaped micromixer using parabolized species equations
    Bothe, Dieter
    Lojewski, Alexander
    Warnecke, Hans-Joachim
    [J]. CHEMICAL ENGINEERING SCIENCE, 2011, 66 (24) : 6424 - 6440
  • [7] Microstructure devices for process intensification: Influence of manufacturing tolerances and design
    Brandner, Juergen J.
    [J]. APPLIED THERMAL ENGINEERING, 2013, 59 (1-2) : 745 - 752
  • [8] Micromixing Within Microfluidic Devices
    Capretto, Lorenzo
    Cheng, Wei
    Hill, Martyn
    Zhang, Xunli
    [J]. MICROFLUIDICS: TECHNOLOGIES AND APPLICATIONS, 2011, 304 : 27 - 68
  • [9] Process intensification by miniaturization
    Charpentier, JC
    [J]. CHEMICAL ENGINEERING & TECHNOLOGY, 2005, 28 (03) : 255 - 258
  • [10] Cortes-Quiroz C. A., 2010, ASME 2010 8 INT C NA