Development of smart inner diameter sensor for position control of Mckibben artificial muscle

被引:18
作者
Akagi, Tetsuya [1 ]
Dohta, Shujiro [1 ]
Kenmotsu, Yuji [1 ]
Zhao, Feifei [2 ]
Yoneda, Masataka [3 ]
机构
[1] Okayama Univ Sci, Kita Ku, 1-1 Ridai Cho, Okayama 7000005, Japan
[2] Tsuyama Natl Coll Technol, Okayama 7088509, Japan
[3] Uozaki Jr High Sch, Kobe, Hyogo 6580025, Japan
来源
INTERNATIONAL SYMPOSIUM ON ROBOTICS AND INTELLIGENT SENSORS 2012 (IRIS 2012) | 2012年 / 41卷
关键词
Rubber artificial muscle; Built-In sensor; Position control; Inner diameter sensor;
D O I
10.1016/j.proeng.2012.07.149
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Due to the ageing and the decreasing birth rate in Japanese society, an important problem of providing nursing care for the elderly has occurred. Therefore, it is strongly desired to develop a wearable actuator to use in nursing care or rehabilitation. The purpose of this study is to develop a high-power flexible actuator with a displacement sensor which can be used in supporting a bathing. In our previous study, we proposed and tested a rubber artificial muscle with the inner diameter sensor. The inner diameter sensor consists of two electric circuit boards with two photo reflectors. Two boards are bonded together to contract the inner diameter sensor. The sensor also has a doughnut-shaped bulkhead to keep a seal. The sensor is inserted into the tube of the artificial muscle. The senor is set at the end of tube. This sensor can be expected to estimate the axial direction displacement of the rubber artificial muscle, because the relation between the inner diameter and the axial directional displacement of the muscle has a strong correlation. However, if the external bending force is applied to the end of the muscle, the inner diameter sensor cannot hold at the center position of the tube. Therefore, the sensor cannot measure the inner diameter exactly. In this study, the improvement of the inner diameter sensor was executed. The improved sensor has 4 photo reflectors on the two electric circuit boards to compensate the measuring error. The position control was also carried out by using the actuator with the built-in inner diameter sensor. As a result, the axial direction displacement of the muscle could be estimated well by the tested inner diameter sensor, and a relatively good position control performance was obtained. (C) 2012 The Authors. Published by Elsevier Ltd. Selection and/or peer-review under responsibility of the Centre of Humanoid Robots and Bio-Sensor (HuRoBs), Faculty of Mechanical Engineering, Universiti Teknologi MARA.
引用
收藏
页码:105 / 112
页数:8
相关论文
共 10 条
[1]  
Akagi T., 2007, T JSME C, V73-735, P2996
[2]  
[Anonymous], [No title captured]
[3]   Measurement and modeling of McKibben pneumatic artificial muscles [J].
Chou, CP ;
Hannaford, B .
IEEE TRANSACTIONS ON ROBOTICS AND AUTOMATION, 1996, 12 (01) :90-102
[4]  
Kobayashi H., 2004, J. Robot. Mechatron., V16, P504, DOI [10.20965/jrm.2004.p0504, DOI 10.20965/JRM.2004.P0504]
[5]  
Kuriyama S., 2009, Inter. J. of Automation Technology, V3, P731, DOI [10.20965/ijat.2009.p0731, DOI 10.20965/IJAT.2009.P0731]
[6]  
Nagata T., 2004, SOFT ACTUATORS FOREF
[7]   Development of Power Assist Wear Using Pneumatic Rubber Artificial Muscles [J].
Noritsugu, Toshiro ;
Takaiwa, Masahiro ;
Sasaki, Daisuke .
JOURNAL OF ROBOTICS AND MECHATRONICS, 2009, 21 (05) :607-613
[8]  
Wakimoto S, 2005, Transducers '05, Digest of Technical Papers, Vols 1 and 2, P745
[9]  
Yoneda M., 2011, P 11 INT C FLUID CON, P1
[10]  
Zhao F., 2010, T JSME C, V76-772, P3665