Correlation between optic nerve head parameters and retinal nerve fibre layer thickness measured by spectral-domain optical coherence tomography in myopic eyes

被引:22
作者
Hwang, Young H. [2 ,3 ]
Kim, Yong Y. [1 ]
机构
[1] Korea Univ, Coll Med, Dept Ophthalmol, Seoul 152703, South Korea
[2] Konyang Univ, Kims Eye Hosp, Myung Gok Eye Res Inst, Dept Ophthalmol, Seoul, South Korea
[3] Armed Forces Capital Hosp, Dept Ophthalmol, Songnam, South Korea
关键词
glaucoma; myopia; optic nerve head; optical coherence tomography; retinal nerve fibre layer; SCANNING LASER OPHTHALMOSCOPY; DISC SIZE; DISEASE SEVERITY; AXIAL LENGTH; STRATUS OCT; GLAUCOMA; DETERMINANTS; DIAMETER;
D O I
10.1111/j.1442-9071.2012.02793.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: To evaluate the correlation between optic nerve head parameters and retinal nerve fiber layer thickness measured by Cirrus HD spectral-domain optical coherence tomography (Cirrus HD-OCT; Carl Zeiss Meditec) in healthy myopic eyes. Design: Cross-sectional study. Participants: One hundred and sixty-one right eyes from 161 healthy young myopic subjects. Methods: Optic nerve head parameters and retinal nerve fiber layer thickness were measured with the Cirrus HD-OCT. The distance between optic disc margin and scan circle (disc margin-to-scan distance) was measured on the Cirrus HD-OCT en-face optic nerve head image with aid of National Institutes of Health ImageJ image-analysis software (developed by Wayne Rasbands, National Institutes of Health, Bethesda, MD). Main Outcome Measures: The correlations among optic nerve head parameters, retinal nerve fibre layer thickness and the disc margin-to-scan distance were evaluated with and without adjustment of the magnification effect. Results: Without correction of the magnification effect, the thicker average retinal nerve fiber layer was correlated with greater rim area and lower degree of myopia (P < 0.001). When the magnification effect was corrected, thicker average retinal nerve fibre layer was associated with greater disc area and greater rim area in univariate and multivariate analyses (P = 0.028); however, degrees of myopia and the disc margin-to-scan distance were not significantly associated with average RNFL thickness (P = 0.104). Conclusions: Thicker average retinal nerve fibre layer thickness was associated with greater rim and disc areas. Disc margin-to-scan distance was not significantly correlated with average retinal nerve fibre layer thickness in healthy myopic eyes.
引用
收藏
页码:713 / 720
页数:8
相关论文
共 34 条
  • [11] JONAS JB, 1992, INVEST OPHTH VIS SCI, V33, P2012
  • [12] Effect of Myopia on the Thickness of the Retinal Nerve Fiber Layer Measured by Cirrus HD Optical Coherence Tomography
    Kang, Shin Hee
    Hong, Seung Woo
    Im, Seong Kyu
    Lee, Sang Hyup
    Ahn, Myung Douk
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (08) : 4075 - 4083
  • [13] Fixed-diameter scan protocol preferable for retinal nerve fibre layer measurement by optical coherence tomography in all sizes of optic discs
    Kaushik, S.
    Pandav, S. S.
    Ichhpujani, P.
    Gupta, A.
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2009, 93 (07) : 895 - 900
  • [14] Factors Associated with False Positives in Retinal Nerve Fiber Layer Color Codes from Spectral-Domain Optical Coherence Tomography
    Kim, Na Rae
    Lim, Hyunsun
    Kim, Ji Hyun
    Rho, Seung Soo
    Seong, Gong Je
    Kim, Chan Yun
    [J]. OPHTHALMOLOGY, 2011, 118 (09) : 1774 - 1781
  • [15] Optic disc measurements in myopia with optical coherence tomography and confocal scanning laser ophthalmoscopy
    Leung, Christopher Kai-shun
    Cheng, Arthur Chak Kwan
    Chong, Kelvin Kam Lung
    Leung, King Sai
    Mohamed, Shaheeda
    Lau, Charles Sing Lok
    Cheung, Carol Yim Lui
    Chu, Geoffrey Chin-hung
    Lai, Ricky Yiu Kwong
    Pang, Calvin Chi Pui
    Lam, Dennis Shun Chiu
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2007, 48 (07) : 3178 - 3183
  • [16] Correlation Between Peripapillary Retinal Nerve Fiber Layer Thickness and Optic Nerve Head Parameters Using Spectral Domain Optical Coherence Tomography
    Mansoori, Tarannum
    Viswanath, Kalluri
    Balakrishna, Nagalla
    [J]. JOURNAL OF GLAUCOMA, 2010, 19 (09) : 604 - 608
  • [17] Optic Nerve Head (ONH) Topographic Analysis by Stratus OCT in Normal Subjects: Correlation to Disc Size, Age, and Ethnicity
    Marsh, Barbara C.
    Cantor, Louis B.
    WuDunn, Darrell
    Hoop, Joni
    Lipyanik, Jennifer
    Patella, Vincent Michael
    Budenz, Donald L.
    Greenfield, David S.
    Savell, Jonathan
    Schuman, Joel S.
    Varma, Rohit
    [J]. JOURNAL OF GLAUCOMA, 2010, 19 (05) : 310 - 318
  • [18] Influence of disease severity and optic disc size on the diagnostic performance of imaging instruments in glaucoma
    Medeiros, FA
    Zangwill, LM
    Bowd, C
    Sample, PA
    Weinreb, RN
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2006, 47 (03) : 1008 - 1015
  • [19] Evaluation of retinal nerve fiber layer, optic nerve head, and macular thickness measurements for glaucoma detection using optical coherence tomography
    Medeiros, FA
    Zangwill, LM
    Bowd, C
    Vessani, RM
    Susanna, R
    Weinreb, RN
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2005, 139 (01) : 44 - 55
  • [20] RELATIONSHIP BETWEEN MORPHOMETRIC OPTIC DISC PARAMETERS, SEX AND AXIAL LENGTH
    MIGLIOR, S
    BRIGATTI, L
    VELATI, P
    BALESTRERI, C
    ROSSETTI, L
    BUJTAR, E
    ORZALESI, N
    [J]. CURRENT EYE RESEARCH, 1994, 13 (02) : 119 - 124