Residual bearing capacity of reinforced concrete member after exposure to high temperature

被引:9
作者
Bai, Lili [1 ]
Wang, Zhenqing [1 ]
机构
[1] Harbin Engn Univ, Coll Aerosp & Civil Engn, Harbin 150001, Peoples R China
来源
ADVANCES IN CIVIL ENGINEERING AND ARCHITECTURE INNOVATION, PTS 1-6 | 2012年 / 368-373卷
关键词
ANSYS; high temperature; bearing capacity; parameters; FIRE;
D O I
10.4028/www.scientific.net/AMR.368-373.577
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
After boundary conditions of member and thermal parameters of materials are determined, ANSYS software is utilized to analyze the maximum temperature distribution in the member under different fire duration. The equivalent cross-section economization method is given to calculate residual bearing capacity of RC member after exposure to high temperature, here, strength of reinforcement is considered as invariant, and the original section area is regarded as reduced. The numerical results are in good agreement with the experiment results of other reference, so appliance of the method is proved, Based on these, some parameters have significant influences on reduced coefficient of residual bearing capacity, such as sectional dimension, fire duration time, strength of reinforcement and concrete, ratio of reinforcement, thickness of fire-protection layer, which are analyzed and theory basis is supplied on safe monitor, repair and reinforcement of RC member after exposure to high temperature.
引用
收藏
页码:577 / 581
页数:5
相关论文
共 11 条
[1]  
Bai Li-li, 2007, Journal of Harbin Engineering University, V28, P1084
[2]  
El-Hawary M.M., 1996, CONSTR BUILD MATER, V10, P147
[3]  
Guo Z.H., 2003, High temperature properties of reinforced concrete and their calculation
[4]  
Kraus A. D., 2001, EXTENDED SURFACE HEA
[5]   Fire engineering design of steel and composite buildings [J].
Lawson, RM .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2001, 57 (12) :1233-1247
[6]  
Lea F.C., 1920, Engineering, V110, P293
[7]  
QU LJ, 1995, CONSTRUCTION TECHNIQ, V22, P293
[8]   Effect of fire on FRP reinforced concrete members [J].
Saafi, M .
COMPOSITE STRUCTURES, 2002, 58 (01) :11-20
[9]  
Wu B, 2003, Mechanical performance of RC structures after fire
[10]  
Yang Yanke, 1992, S YOUNG EXP LEARN M