Denoising of 4D Cardiac Micro-CT Data Using Median-Centric Bilateral Filtration

被引:9
作者
Clark, D. [1 ]
Johnson, G. A. [1 ]
Badea, C. T. [1 ]
机构
[1] Duke Univ, Med Ctr, Dept Radiol, Ctr Vivo Microscopy, Durham, NC 27710 USA
来源
MEDICAL IMAGING 2012: IMAGE PROCESSING | 2012年 / 8314卷
关键词
micro-CT; in vivo; small animal; cardiac imaging; bilateral filtration; 4D; denoising;
D O I
10.1117/12.911478
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Bilateral filtration has proven an effective tool for denoising CT data. The classic filter uses Gaussian domain and range weighting functions in 2D. More recently, other distributions have yielded more accurate results in specific applications, and the bilateral filtration framework has been extended to higher dimensions. In this study, brute-force optimization is employed to evaluate the use of several alternative distributions for both domain and range weighting: Andrew's Sine Wave, El Fallah Ford, Gaussian, Flat, Lorentzian, Huber's Minimax, Tukey's Bi-weight, and Cosine. Two variations on the classic bilateral filter, which use median filtration to reduce bias in range weights, are also investigated: median-centric and hybrid bilateral filtration. Using the 4D MOBY mouse phantom reconstructed with noise (stdev. similar to 65 HU), hybrid bilateral filtration, a combination of the classic and median-centric filters, with Flat domain and range weighting is shown to provide optimal denoising results (PSNRs: 31.69, classic; 31.58 median-centric; 32.25, hybrid). To validate these phantom studies, the optimal filters are also applied to in vivo, 4D cardiac micro-CT data acquired in the mouse. In a constant region of the left ventricle, hybrid bilateral filtration with Flat domain and range weighting is shown to provide optimal smoothing (stdev: original, 72.2 HU; classic, 20.3 HU; median-centric, 24.1 HU; hybrid, 15.9 HU). While the optimal results were obtained using 4D filtration, the 3D hybrid filter is ultimately recommended for denoising 4D cardiac micro-CT data, because it is more computationally tractable and less prone to artifacts (MOBY PSNR: 32.05; left ventricle stdev: 20.5 HU).
引用
收藏
页数:12
相关论文
共 13 条
[1]   Micro-CT with respiratory and cardiac gating [J].
Badea, C ;
Hedlund, LW ;
Johnson, GA .
MEDICAL PHYSICS, 2004, 31 (12) :3324-3329
[2]  
Badea C. T., 2008, P SOC PHOTO-OPT INS, V6913
[3]   Accelerating Spatially Varying Gaussian Filters [J].
Baek, Jongmin ;
Jacobs, David E. .
ACM TRANSACTIONS ON GRAPHICS, 2010, 29 (06)
[4]   PRACTICAL CONE-BEAM ALGORITHM [J].
FELDKAMP, LA ;
DAVIS, LC ;
KRESS, JW .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06) :612-619
[5]  
Francis J., 2003, P 14 ANN S PATT REC
[6]   Rapid Production of Specialized Animal Handling Devices Using Computer-Aided Design and Solid Freeform Fabrication [J].
Howles, Gabriel P. ;
Nouls, John C. ;
Qi, Yi ;
Johnson, G. Allan .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 30 (02) :466-471
[7]   A liposomal nanoscale contrast agent for preclinical CT in mice [J].
Mukundan, S ;
Ghaghada, KB ;
Badea, CT ;
Kao, CY ;
Hedlund, LW ;
Provenzale, JM ;
Johnson, GA ;
Chen, E ;
Bellamkonda, RV ;
Annapragada, A .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 186 (02) :300-307
[8]   OPTIMAL SHORT SCAN CONVOLUTION RECONSTRUCTION FOR FANBEAM CT [J].
PARKER, DL .
MEDICAL PHYSICS, 1982, 9 (02) :254-257
[9]   Low-dose cardio-respiratory phase-correlated cone-beam micro-CT of small animals [J].
Sawall, Stefan ;
Bergner, Frank ;
Lapp, Robert ;
Mronz, Markus ;
Karolczak, Marek ;
Hess, Andreas ;
Kacheliress, Marc .
MEDICAL PHYSICS, 2011, 38 (03) :1416-1424
[10]   Development of a 4-D digital mouse phantom for molecular imaging research [J].
Segars, WP ;
Tsui, BMW ;
Frey, EC ;
Johnson, GA ;
Berr, SS .
MOLECULAR IMAGING AND BIOLOGY, 2004, 6 (03) :149-159