Experimental and numerical investigation of the tracer gas methodology in the case of a naturally cross-ventilated building

被引:34
|
作者
Nikolopoulos, Nikos [1 ]
Nikolopoulos, Aristeidis [1 ]
Larsen, Tine S. [2 ]
Nikas, Konstantinos-Stefanos P. [1 ]
机构
[1] Technol Educ Inst Piraeus, Dept Mech Engn, Fluid Mech Lab, Aigaleo 12244, Greece
[2] Aalborg Univ, Dept Civil Engn, Aalborg 9000, Denmark
关键词
Natural ventilation; CFD; Tracer gas methodology; Building; WIND-TUNNEL; RATES;
D O I
10.1016/j.buildenv.2012.04.006
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents the investigation of a naturally cross-ventilated building using both experimental and numerical methods with parameter being the incidence angle of the wind to the openings of the building. The experimental methodology calculates the air change rate based either on measurements of the inlet velocity profile, the outlet velocity profile or the descending rate of the tracer gas mass concentration using the decay method. The numerical investigation is based on the solution of the governing Reynolds averaged Navier-Stokes equations in their full three dimensional expression, focusing on the time dependent character of the induced flow field. The numerical results are compared with corresponding experimental data for the three aforementioned experimental methodologies in the case of a full-scale building inside a wind tunnel. The numerical investigation reveals that for large incidence angle the flow is governed by an unsteady character regarding especially the regions close to the inlet and outlet windows. It is concluded that: velocity measurements in the inlet window are of high accuracy when the flow in this region has a steady character, whilst the decay method is depicting the effective air change rate in a control volume and not the intended one. Finally, conclusions about the air change rate spatial distribution in the control volume of the building are provided as a function of the incidence angle, revealing that its accuracy as a method for measuring the intended aeration rate depends significantly on the mixing of gas within the control volume of the building. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:379 / 388
页数:10
相关论文
共 50 条
  • [1] Numerical study of a naturally cross-ventilated building
    Nikas, K. -S.
    Nikolopoulos, N.
    Nikolopoulos, A.
    ENERGY AND BUILDINGS, 2010, 42 (04) : 422 - 434
  • [2] Numerical investigation on the effects of building configuration on discharge coefficient for a cross-ventilated dairy building model
    Yi, Qianying
    Li, Hao
    Wang, Xiaoshuai
    Zong, Chao
    Zhang, Guoqiang
    BIOSYSTEMS ENGINEERING, 2019, 182 : 107 - 122
  • [3] Effect of internal partition on a naturally cross-ventilated generic building using computational fluid dynamics
    Fam, Y. H.
    Tai, V. C.
    Mathew, P. R.
    Tan, Y. C.
    Moey, L. K.
    JOURNAL OF MECHANICAL ENGINEERING AND SCIENCES, 2024, 18 (04) : 10279 - 10289
  • [4] Computational fluid dynamics for cross-ventilated airflow in a urban building
    Hirose, Chiyoko
    Ikegaya, Naoki
    Hagishima, Aya
    Tanimoto, Jun
    JAPAN ARCHITECTURAL REVIEW, 2022, 6 (01):
  • [5] Investigation of response surface methodology for modelling ventilation rate of a naturally ventilated building
    Shen, Xiong
    Zhang, Guoqiang
    Bjerg, Bjarne
    BUILDING AND ENVIRONMENT, 2012, 54 : 174 - 185
  • [6] Animal welfare in cross-ventilated, compost-bedded pack, and naturally ventilated dairy barns in the upper Midwest
    Lobeck, K. M.
    Endres, M. I.
    Shane, E. M.
    Godden, S. M.
    Fetrow, J.
    JOURNAL OF DAIRY SCIENCE, 2011, 94 (11) : 5469 - 5479
  • [7] Numerical investigation of droplets in a cross-ventilated space with sitting passengers under asymptomatic virus transmission conditions
    Pena-Monferrer, C.
    Antao, S.
    Manson-Sawko, R.
    PHYSICS OF FLUIDS, 2021, 33 (12)
  • [8] Experimental investigation and CFD analysis of cross-ventilated flow through single room detached house model
    Kobayashi, Tomohiro
    Sandberg, Mats
    Kotani, Hisashi
    Claesson, Leif
    BUILDING AND ENVIRONMENT, 2010, 45 (12) : 2723 - 2734
  • [9] On the effect of pressure coefficient source on the energy demand of an isolated cross-ventilated building
    Vasaturo, R.
    van Hooff, T.
    Gillmeier, S.
    Blocken, B.
    van Wesemael, P. J. V.
    BUILDING AND ENVIRONMENT, 2024, 255
  • [10] Evaluation of different window heights and facade porosities in naturally cross-ventilated buildings: CFD validation
    Diaz-Calderon, S. F.
    Castillo, J. A.
    Huelsz, G.
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2023, 232