Breakdown and Partial Discharge Characteristics of Transformer Board and Insulating Paper Materials in Liquid Nitrogen

被引:8
作者
Garzem, Michael [1 ]
Grunwald, Marcel [1 ]
Schnorrenberg, Rene [1 ]
Schumacher, Ralph [1 ]
Humpert, Christof [1 ]
机构
[1] TH Koln Univ Appl Sci, Inst Elect Power Engn, Lab High Voltage Engn, D-50679 Cologne, Germany
关键词
Dielectric breakdown; insulating paper; liquid nitrogen; partial discharges; transformer board;
D O I
10.1109/TASC.2018.2805166
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Breakdown (BD) and partial discharge (PD) characteristics of insulating paper and transformer board materials are investigated as cost-effective alternatives to high-price materials like polyimide (PI) or polytetrafluoroethylene and fiber reinforced plastic materials typically used in superconducting devices based on high temperature superconductors cooled with liquid nitrogen (LN2). Three different cotton and cellulose based insulating papers are tested in LN2 at atmospheric pressure and compared to synthetic sheet materials and polypropylene laminated paper (PPLP). Additionally, the BD performance and PD characteristics of three different transformer board materials are investigated in LN2. The results reveal that the paper and board materials have nearly the same or even slightly higher BD voltages in LN2 in comparison to the values in insulating oil. The pure paper materials with thicknesses of 130 mu m have a dielectric strength of 70-90 kV/mm, whereas values of 130-140 kV/mm are measured for PPLP and PI with nearly the same thickness. The dielectric strength of the board materials has a maximum value of 76 kV/mm. In the frame of the investigations, the BD performance of the pure paper materials in LN2 is not influenced by the water content of the materials, dried and undried specimens have nearly the same BD voltage. Only the PPLP material has a 15% higher BD voltage in the dried state in comparison to the undried state.
引用
收藏
页数:5
相关论文
共 19 条
[1]  
[Anonymous], 2013, DUPONT TEFL FEP FLUO
[2]  
[Anonymous], 2016, TERVAKOSKI FILM IPO
[3]  
[Anonymous], 2011, EL INS PAP
[4]  
[Anonymous], 2016, P 8 IET INT C POW EL, DOI DOI 10.1049/CP.2016.0219
[5]  
[Anonymous], 2013, TRANSF CELL INS UNS
[6]  
DuPont, 2011, DUPONT KAPT HN POL F
[7]   Discussion on application of the Weibull distribution to electrical breakdown of insulating materials [J].
Fabiani, D ;
Simoni, L .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2005, 12 (01) :11-16
[8]   Recent Progress in Electrical Insulation Techniques for HTS Power Apparatus [J].
Hayakawa, Naoki ;
Kojima, Hiroki ;
Hanai, Masahiro ;
Okubo, Hitoshi .
SUPERCONDUCTIVITY CENTENNIAL CONFERENCE 2011, 2012, 36 :1305-1308
[9]   Manufacturing of a 1-MVA-Class Superconducting Fault Current Limiting Transformer With Recovery-Under-Load Capabilities [J].
Hellmann, Sebastian ;
Abplanalp, Markus ;
Hofstetter, Lukas ;
Noe, Mathias .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2017, 27 (04)
[10]   Study on the Dielectric Characteristics of Gaseous, Liquid, and Solid Insulation Materials for a High Voltage Superconducting Apparatus [J].
Hong, Jonggi ;
Heo, Jeong Il ;
Nam, Seokho ;
Kang, Hyoungku .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2013, 23 (03)