Modified look-locker inversion recovery T1 mapping indices: assessment of accuracy and reproducibility between magnetic resonance scanners
被引:58
|作者:
Raman, Fabio S.
[1
]
Kawel-Boehm, Nadine
[1
,2
]
Gai, Neville
[1
]
Freed, Melanie
[3
]
Han, Jing
[4
]
Liu, Chia-Ying
[1
]
Lima, Joao A. C.
[5
]
Bluemke, David A.
[1
,6
]
Liu, Songtao
[1
,6
]
机构:
[1] NIH, Ctr Clin, Bethesda, MD 20892 USA
[2] Univ Basel Hosp, Clin Radiol & Nucl Med, CH-4031 Basel, Switzerland
[3] NYU, Sch Med, New York, NY USA
[4] US FDA, Rockville, MD 20857 USA
[5] Johns Hopkins Univ, Sch Med, Div Cardiol, Baltimore, MD USA
[6] Natl Inst Biomed Imaging & Bioengn, Mol Biomed Imaging Lab, Bethesda, MD USA
基金:
美国国家卫生研究院;
关键词:
T1;
mapping;
Partition coefficient (lambda);
Extracellular volume fraction (ECV);
Diffuse myocardial fibrosis;
Modified look-locker with inversion recovery (MOLLI);
DIFFUSE MYOCARDIAL FIBROSIS;
EXTRACELLULAR VOLUME FRACTION;
INTRAINDIVIDUAL ASSESSMENT;
GD-DTPA;
VALIDATION;
QUANTIFICATION;
ASSOCIATION;
RELAXATION;
INFARCTION;
SHMOLLI;
D O I:
10.1186/1532-429X-15-64
中图分类号:
R5 [内科学];
学科分类号:
1002 ;
100201 ;
摘要:
Background: Cardiovascular magnetic resonance (CMR) T1 mapping indices, such as T1 time and partition coefficient (lambda), have shown potential to assess diffuse myocardial fibrosis. The purpose of this study was to investigate how scanner and field strength variation affect the accuracy and precision/reproducibility of T1 mapping indices. Methods: CMR studies were performed on two 1.5T and three 3T scanners. Eight phantoms were made to mimic the T1/T2 of pre- and post-contrast myocardium and blood at 1.5T and 3T. T1 mapping using MOLLI was performed with simulated heart rate of 40-100 bpm. Inversion recovery spin echo (IR-SE) was the reference standard for T1 determination. Accuracy was defined as the percent error between MOLLI and IR-SE, and scan/re-scan reproducibility was defined as the relative percent mean difference between repeat MOLLI scans. Partition coefficient was estimated by Delta R1myocardium phantom/Delta R1blood phantom. Generalized linear mixed model was used to compare the accuracy and precision/reproducibility of T1 and lambda across field strength, scanners, and protocols. Results: Field strength significantly affected MOLLI T1 accuracy (6.3% error for 1.5T vs. 10.8% error for 3T, p<0.001) but not lambda accuracy (8.8% error for 1.5T vs. 8.0% error for 3T, p=0.11). Partition coefficients of MOLLI were not different between two 1.5T scanners (47.2% vs. 47.9%, p=0.13), and showed only slight variation across three 3T scanners (49.2% vs. 49.8% vs. 49.9%, p=0.016). Partition coefficient also had significantly lower percent error for precision (better scan/re-scan reproducibility) than measurement of individual T1 values (3.6% for lambda vs. 4.3%-4.8% for T1 values, approximately, for pre/post blood and myocardium values). Conclusion: Based on phantom studies, T1 errors using MOLLI ranged from 6-14% across various MR scanners while errors for partition coefficient were less (6-10%). Compared with absolute T1 times, partition coefficient showed less variability across platforms and field strengths as well as higher precision.