A reusable quartz crystal microbalance biosensor for highly specific detection of single-base DNA mutation

被引:40
作者
Wang, Dingzhong [1 ]
Chen, Gengjia [1 ]
Wang, Huaming [1 ]
Tang, Wei [1 ]
Pan, Wei [1 ]
Li, Na [1 ]
Liu, Feng [1 ]
机构
[1] Peking Univ, Beijing Natl Lab Mol Sci, Key Lab Bioorgan Chem & Mol Engn, Minist Educ,Coll Chem & Mol Engn, Beijing 100871, Peoples R China
基金
中国国家自然科学基金;
关键词
Toehold-mediated strand displacement reaction; Quartz crystal microbalance; Reusable biosensor; Single-base DNA mutation; CORONARY-HEART-DISEASE; HYBRIDIZATION; SENSOR; PROBE; OLIGONUCLEOTIDES; REAGENTLESS; MACHINE; MTHFR;
D O I
10.1016/j.bios.2013.04.035
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A reusable quartz crystal microbalance (QCM) biosensor based on the toehold-mediated strand displacement reaction (SDR) is first developed for highly specific detection of single-base DNA mutation. N-5, N-10-methylenetetrahydrofolate reductase (MTHFR) gene C677T mutation is chosen as a model to investigate the performance of the constructed biosensor. The capture DNA immobilized on the gold electrode surface of QCM hybridizes with the conjugate of biotinylated reporter DNA and streptavidin (abbreviated to reporter probe) to form the recognition layer. A toehold domain in the reporter DNA is specifically designed to bind the complementary mutant DNA and trigger the SDR, eventually resulting in the release of the complex of reporter probe and mutant DNA from the gold surface, and then the recognition layer is mildly regenerated by subsequently injecting the reporter probe again. The fabricated biosensor shows good repeatability for the mutant DNA, as more than 87% signal intensity of the sensor remained after six repetitive measurements. A linear range of 1-75 nM is achieved with a detection limit of 0.8 nM at room temperature. This biosensor also affords remarkable specificity to the mutant DNA against its wild-type DNA with a discrimination factor of 33. The potential of applying this biosensor in screening real samples is confirmed by spiked HeLa cells lysate with a recovery of 108%. The proposed sensing strategy provides a simple and universal solution for repetitive and highly specific detection of single-base DNA mutation. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:276 / 280
页数:5
相关论文
共 23 条
[1]   DNA duplex-quadruplex exchange as the basis for a nanomolecular machine [J].
Alberti, P ;
Mergny, JL .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2003, 100 (04) :1569-1573
[2]   Comparative advantages of mechanical biosensors [J].
Arlett, J. L. ;
Myers, E. B. ;
Roukes, M. L. .
NATURE NANOTECHNOLOGY, 2011, 6 (04) :203-215
[3]   Insights into Metabolic Mechanisms Underlying Folate-Responsive Neural Tube Defects: A Minireview [J].
Beaudin, Anna E. ;
Stover, Patrick J. .
BIRTH DEFECTS RESEARCH PART A-CLINICAL AND MOLECULAR TERATOLOGY, 2009, 85 (04) :274-284
[4]   Amplified QCM-D biosensor for protein based on aptamer-functionalized gold nanoparticles [J].
Chen, Qiang ;
Tang, Wei ;
Wang, Dingzhong ;
Wu, Xiaojie ;
Li, Na ;
Liu, Feng .
BIOSENSORS & BIOELECTRONICS, 2010, 26 (02) :575-579
[5]   Detection of C677T mutation of MTHFR in subject with coronary heart disease by hairpin probe with enzymatic color on microarray [J].
Chen, Qinghai ;
Sun, Yue ;
Zhang, Linqun ;
Deng, Kun ;
Xia, Han ;
Xing, Hua ;
Xiang, Yang ;
Ran, Boli ;
Zhang, Mohan ;
Xu, Xiaodong ;
Fu, Weiling .
BIOSENSORS & BIOELECTRONICS, 2011, 28 (01) :84-90
[6]   Optical and electrochemical DNA nanobiosensors [J].
Dolatabadi, Jafar Ezzati Nazhad ;
Mashinchian, Omid ;
Ayoubi, Baharak ;
Jamali, Ali Akbar ;
Mobed, Ahmad ;
Losic, Dusan ;
Omidi, Yadollah ;
de la Guardia, Miguel .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2011, 30 (03) :459-472
[7]   Electrochemical detection of DNA hybridization by means of osmium tetroxide complexes and protective oligonucleotides [J].
Flechsig, Gerd-Uwe ;
Reske, Thomas .
ANALYTICAL CHEMISTRY, 2007, 79 (05) :2125-2130
[8]   MTHFR 677C→T polymorphism and risk of coronary heart disease -: A meta-analysis [J].
Klerk, M ;
Verhoef, P ;
Clarke, R ;
Blom, HJ ;
Kok, FJ ;
Schouten, EG .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2002, 288 (16) :2023-2031
[9]   Binary Probes for Nucleic Acid Analysis [J].
Kolpashchikov, Dmitry M. .
CHEMICAL REVIEWS, 2010, 110 (08) :4709-4723
[10]   Aptamer-Based Electrochemical Biosensor for Interferon Gamma Detection [J].
Liu, Ying ;
Tuleouva, Nazgul ;
Ramanculov, Erlan ;
Revzin, Alexander .
ANALYTICAL CHEMISTRY, 2010, 82 (19) :8131-8136