Speckle suppression and contrast enhancement in reconstruction of freehand 3D ultrasound images using an adaptive distance-weighted method

被引:35
作者
Huang, Qinghua [1 ,3 ]
Lu, Minhua [2 ]
Zheng, Yongping [3 ]
Chi, Zheru [4 ]
机构
[1] City Univ Hong Kong, Dept Elect Engn, Kowloon, Hong Kong, Peoples R China
[2] Shenzhen Univ, Dept Biomed Engn, Shenzhen, Peoples R China
[3] Hong Kong Polytech Univ, Dept Hlth Technol & Informat, Kowloon, Hong Kong, Peoples R China
[4] Hong Kong Polytech Univ, Elect & Informat Engn Dept, Ctr Multimedia Signal Proc & Commun, Kowloon, Hong Kong, Peoples R China
关键词
3D ultrasound; Adaptive distance-weighted interpolation; Volume reconstruction; Speckle suppression; Contrast enhancement; 3-D ULTRASOUND; 3-DIMENSIONAL ULTRASOUND; FILTER; SYSTEM; INTERPOLATION; REGISTRATION; CALIBRATION; REDUCTION; TISSUES;
D O I
10.1016/j.apacoust.2008.02.002
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In three-dimensional (3D) freehand ultrasound (US), reconstructing a set of B-scans into a regular voxel array is the key procedure for consequent visualization and analysis. This paper presents a new adaptive interpolation algorithm for computing the voxel array to suppress speckle noises and enhance contrast. The local statistics of homogeneous regions including mean and variance were measured and the ratio of variance to mean was used as homogeneity criteria. For the computation of each voxel, the interpolation method was adaptively determined with respect to its local statistics. If the neighbouring pixels of a voxel satisfied the homogeneity criterion, its value was computed with an arithmetic mean filter. Otherwise, the voxel was probably locating in an inhomogeneous region and an adaptive distance-weighted (ADW) interpolation method was employed to compute its value. A resolution phantom and a subject's forearm were reconstructed using the proposed algorithm and two other well-known methods - conventional distance-weighted (DW) and voxel nearest neighbourhood (VNN) interpolations. The comparison results demonstrated that the adaptive interpolation algorithm was able to suppress speckles, preserve edges and enhance contrast effectively for the volume reconstruction. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:21 / 30
页数:10
相关论文
共 28 条
[1]   Three-dimensional freehand ultrasound: Image reconstruction and volume analysis [J].
Barry, CD ;
Allott, CP ;
John, NW ;
Mellor, PM ;
Arundel, PA ;
Thomson, DS ;
Waterton, JC .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (08) :1209-1224
[2]   Aggressive region growing for speckle reduction in ultrasound images [J].
Chen, Y ;
Yin, RM ;
Flynn, R ;
Broschat, S .
PATTERN RECOGNITION LETTERS, 2003, 24 (4-5) :677-691
[3]   Three-dimensional ultrasound imaging [J].
Fenster, A ;
Downey, DB ;
Cardinal, HN .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (05) :R67-R99
[4]   Engineering a freehand 3D ultrasound system [J].
Gee, A ;
Prager, R ;
Treece, G ;
Berman, L .
PATTERN RECOGNITION LETTERS, 2003, 24 (4-5) :757-777
[5]   Rapid registration for wide field of view freehand three-dimensional ultrasound [J].
Gee, AH ;
Treece, GM ;
Prager, RW ;
Cash, CJC ;
Berman, L .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2003, 22 (11) :1344-1357
[6]   3-D measurement of body tissues based on ultrasound images with 3-D spatial information [J].
Huang, QH ;
Zheng, YP ;
Li, R ;
Lu, MH .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (12) :1607-1615
[7]   A new scanning approach for limb extremities using a water bag in freehand 3-D ultrasound [J].
Huang, QH ;
Zheng, YP .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (04) :575-583
[8]   Development of a portable 3D ultrasound imaging system for musculoskeletal tissues [J].
Huang, QH ;
Zheng, YP ;
Lu, MH ;
Chi, ZR .
ULTRASONICS, 2005, 43 (03) :153-163
[9]  
HUANG QH, 2008, ULTRASONICS IN PRESS
[10]   An adaptive squared-distance-weighted interpolation for volume reconstruction in 3D freehand ultrasound [J].
Huang, Qing-Hua ;
Zheng, Yong-Ping .
ULTRASONICS, 2006, 44 (e73-e77) :E73-E77