Tissue-Volume Preserving Deformable Image Registration for 4DCT Pulmonary Images

被引:2
作者
Zhao, Bowen [1 ]
Christensen, Gary E. [1 ]
Song, Joo Hyun [1 ]
Pan, Yue [1 ]
Gerard, Sarah E. [1 ]
Reinhardt, Joseph M. [1 ]
Du, Kaifang [2 ]
Patton, Taylor [2 ]
Bayouth, John M. [2 ]
Hugo, Geoffrey D. [3 ]
机构
[1] Univ Iowa, Iowa City, IA 52242 USA
[2] Univ Wisconsin, Madison, WI 53706 USA
[3] Virginia Commonwealth Univ, 401 Coll St, Richmond, VA 23229 USA
来源
PROCEEDINGS OF 29TH IEEE CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION WORKSHOPS, (CVPRW 2016) | 2016年
关键词
4D image registration; groupwise image registration; sum of squared tissue volume difference; mass preservation; temporal smoothness; radiation therapy; treatment planning; NONRIGID REGISTRATION; MOTION; CT;
D O I
10.1109/CVPRW.2016.67
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
e propose a 4D (three spatial dimensions plus time) tissue-volume preserving non-rigid image registration algorithm for pulmonary 4D computed tomography (4DCT) data sets to provide relevant information for radiation therapy and estimate pulmonary ventilation. The sum of squared tissue volume difference (SSTVD) similarity cost takes into account the CT intensity changes of spatially corresponding voxels, which is caused by the variations of fraction of tissue within voxels throughout the respiratory cycle. The proposed 4D SSTVD registration scheme considers the entire dynamic 4D data set simultaneously, using both spatial and temporal information. We employed a uniform 4D cubic B-spline parametrization of the transform and a temporally extended linear elasticity regularization of deformation field to ensure temporal smoothness and thus biological plausibility of estimated deformation. We used a multi-resolution multi-grid registration framework with limited-memory Broyden Fletcher Goldfarb Shanno (L-BFGS) optimization procedure for rapid convergence and limited memory consumption. We conducted experiments using synthetic 2D+t images and clinical 4DCT pulmonary data sets and evaluated accuracy and temporal smoothness of the proposed method via manually annotated landmarks.
引用
收藏
页码:481 / 489
页数:9
相关论文
共 18 条
[1]  
[Anonymous], MED IM COMP COMP ASS
[2]   Tracking lung tissue motion and expansion/compression with inverse consistent image registration and spirometry [J].
Christensen, Gary E. ;
Song, Joo Hyun ;
Lu, Wei ;
El Naqa, Issarn ;
Low, Daniel A. .
MEDICAL PHYSICS, 2007, 34 (06) :2155-2163
[3]   Consistent image registration [J].
Christensen, GE ;
Johnson, HJ .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2001, 20 (07) :568-582
[4]   Estimation of the delivered patient dose in lung IMRT treatment based on deformable registration of 4D-CT data and Monte Carlo simulations [J].
Flampouri, Stella ;
Jiang, Steve B. ;
Sharp, Greg C. ;
Wolfgang, John ;
Patel, Abhijit A. ;
Choi, Noah C. .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (11) :2763-2779
[5]   Mass preserving image registration for lung CT [J].
Gorbunova, Vladlena ;
Sporring, Jon ;
Lo, Pechin ;
Loeve, Martine ;
Tiddens, Harm A. ;
Nielsen, Mads ;
Dirksen, Asger ;
de Bruijne, Marleen .
MEDICAL IMAGE ANALYSIS, 2012, 16 (04) :786-795
[6]   elastix: A Toolbox for Intensity-Based Medical Image Registration [J].
Klein, Stefan ;
Staring, Marius ;
Murphy, Keelin ;
Viergever, Max A. ;
Pluim, Josien P. W. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2010, 29 (01) :196-205
[7]   Advances in 4D medical imaging and 4D radiation therapy [J].
Li, Guang ;
Citrin, Deborah ;
Camphausen, Kevin ;
Mueller, Boris ;
Burman, Chandra ;
Mychalczak, Borys ;
Miller, Robert W. ;
Song, Yulin .
TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2008, 7 (01) :67-81
[8]   ON THE LIMITED MEMORY BFGS METHOD FOR LARGE-SCALE OPTIMIZATION [J].
LIU, DC ;
NOCEDAL, J .
MATHEMATICAL PROGRAMMING, 1989, 45 (03) :503-528
[9]   A continuous 4D motion model from multiple respiratory cycles for use in lung radiotherapy [J].
McClelland, Jamie R. ;
Blackall, Jane M. ;
Tarte, Segolene ;
Chandler, Adam C. ;
Hughes, Simon ;
Ahmad, Shahreen ;
Landau, David B. ;
Hawkes, David J. .
MEDICAL PHYSICS, 2006, 33 (09) :3348-3358
[10]   Nonrigid registration of dynamic medical imaging data using nD plus t B-splines and a groupwise optimization approach [J].
Metz, C. T. ;
Klein, S. ;
Schaap, M. ;
van Walsum, T. ;
Niessen, W. J. .
MEDICAL IMAGE ANALYSIS, 2011, 15 (02) :238-249