Transduction platforms and biointerfacial design of biosensors for 'real-time' biomolecular interaction analysis

被引:23
作者
Quinn, JG [1 ]
O'Kennedy, R [1 ]
机构
[1] Dublin City Univ, Sch Biotechnol, Dublin 9, Ireland
关键词
surface plasmon resonance; evanescent field; 'real-time'; immobilisation; biosensor;
D O I
10.1080/00032719908542911
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The field of biomolecular interaction analysis has been revolutionised over the past decade with the development of biosensors that enable 'real-time' monitoring. Characteristically, these biosensing technologies combine mass sensitive transducers, biointerfacial chemistry and the specificity of a wide range of affinity ligands. Considerable development of these elements has occurred over the past few years and promises to create a new generation of portable biosensors. The majority of transducers for 'real-time' biomolecular interaction analysis are generic evanescent wave-based mass sensors or direct mass sensors. The construction of a suitable biointerface is a key component in biosensor design and has a critical influence on the biosensor's performance. Recent developments in these areas are presented with particular emphasis on commercially available technology.
引用
收藏
页码:1475 / 1517
页数:43
相关论文
共 140 条
[21]   QUANTITATIVE-ANALYSIS OF PROTEIN-INTERACTION WITH LIGANDS .2. ANALYSIS OF MACROMOLECULAR INTERACTIONS USING IMMOBILIZED LIGANDS [J].
CHAIKEN, I ;
ROSE, S ;
KARLSSON, R .
ANALYTICAL BIOCHEMISTRY, 1992, 201 (02) :197-210
[22]   COADSORPTION OF FERROCENE-TERMINATED AND UNSUBSTITUTED ALKANETHIOLS ON GOLD - ELECTROACTIVE SELF-ASSEMBLED MONOLAYERS [J].
CHIDSEY, CED ;
BERTOZZI, CR ;
PUTVINSKI, TM ;
MUJSCE, AM .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1990, 112 (11) :4301-4306
[23]   Direct immunosensing with an integrated-optical output grating coupler [J].
Clerc, D ;
Lukosz, W .
SENSORS AND ACTUATORS B-CHEMICAL, 1997, 40 (01) :53-58
[24]   Surface plasmon resonance analysis at a supported lipid monolayer [J].
Cooper, MA ;
Try, AC ;
Carroll, J ;
Ellar, DJ ;
Williams, DH .
BIOCHIMICA ET BIOPHYSICA ACTA-BIOMEMBRANES, 1998, 1373 (01) :101-111
[25]   THE RESONANT MIRROR - A NOVEL OPTICAL BIOSENSOR FOR DIRECT SENSING OF BIOMOLECULAR INTERACTIONS .1. PRINCIPLE OF OPERATION AND ASSOCIATED INSTRUMENTATION [J].
CUSH, R ;
CRONIN, JM ;
STEWART, WJ ;
MAULE, CH ;
MOLLOY, J ;
GODDARD, NJ .
BIOSENSORS & BIOELECTRONICS, 1993, 8 (7-8) :347-353
[26]   ACOUSTIC PLATE MODE SENSOR FOR IMMUNOCHEMICAL REACTIONS [J].
DAHINT, R ;
GRUNZE, M ;
JOSSE, F ;
RENKEN, J .
ANALYTICAL CHEMISTRY, 1994, 66 (18) :2888-2892
[27]   SOL-GEL ENCAPSULATION METHODS FOR BIOSENSORS [J].
DAVE, BC ;
DUNN, B ;
VALENTINE, JS ;
ZINK, JI .
ANALYTICAL CHEMISTRY, 1994, 66 (22) :A1120-A1127
[28]  
DEBRUIJN HE, 1992, APPL OPTICS, V31, P440, DOI 10.1364/AO.31.0440_1
[29]   Integrated optical Mach-Zehnder interferometers as simazine immunoprobes [J].
Drapp, B ;
Piehler, J ;
Brecht, A ;
Gauglitz, G ;
Luff, BJ ;
Wilkinson, JS ;
Ingenhoff, J .
SENSORS AND ACTUATORS B-CHEMICAL, 1997, 39 (1-3) :277-282
[30]   FLUORESCENT AND PHOSPHORESCENT STUDY OF LANGMUIR-BLODGETT ANTIBODY FILMS FOR APPLICATION TO IMMUNOSENSORS [J].
DUBROVSKY, TB ;
DEMCHEVA, MV ;
SAVITSKY, AP ;
MANTROVA, EY ;
YAROPOLOV, AI ;
SAVRANSKY, VV ;
BELOVOLOVA, LV .
BIOSENSORS & BIOELECTRONICS, 1993, 8 (7-8) :377-385