Air-kerma strength determination of a 169Yb high dose rate brachytherapy source

被引:3
作者
VanDamme, J. J. [1 ]
Culberson, W. S. [1 ]
DeWerd, L. A. [1 ]
Micka, J. A. [1 ]
机构
[1] Univ Wisconsin, Med Radiat Res Ctr, Madison, WI 53706 USA
关键词
calibration; HDR;
D O I
10.1118/1.2964094
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The increased demand for high dose rate (HDR) brachytherapy as an alternative to external beam radiotherapy has led to the introduction of a HDR brachytherapy isotope Yb-169. This source offers a dose rate similar to Ir-192 HDR sources, at about one fourth the effective photon energy. This work presents the calibration of this source in terms of air-kerma strength, based on an adaptation of the current, National Institute of Standards and Technology traceable, in air measurement technique currently used for Ir-192 HDR sources. Several additional measurement correction factors were required, including corrections for air scatter, air attenuation, and ion recombination. A new method is introduced for determining the ion chamber calibration coefficient (NkYb)-Yb-169. An uncertainty analysis was also performed, indicating an overall measurement expanded uncertainty in the air-kerma strength (k=2) of 2.2%. (C) 2008 American Association of Physicists in Medicine.
引用
收藏
页码:3935 / 3942
页数:8
相关论文
共 27 条
  • [21] A Monte Carlo investigation of the dosimetric characteristics of the VariSource 192Ir high dose rate brachytherapy source
    Karaiskos, P
    Angelopoulos, A
    Baras, P
    Sakelliou, L
    Sandilos, P
    Dardoufas, K
    Vlachos, L
    MEDICAL PHYSICS, 1999, 26 (08) : 1498 - 1502
  • [22] Comparison of high-dose-rate 192Ir source strength measurements using equipment with traceability to different standards
    Tedgren, Asa Carlsson
    Bjerke, Hans
    Grindborg, Jan-Erik
    Hetland, Per-Otto
    Kosunen, Antti
    Hellebust, Taran Paulsen
    Persson, Linda
    Sipila, Petri
    BRACHYTHERAPY, 2014, 13 (04) : 420 - 423
  • [23] Independent assessment of source transit time for the BEBIG SagiNova® cobalt-60 high dose rate brachytherapy afterloader
    Kanani, Abolfazl
    Karbasi, Sareh
    Mosleh-Shirazi, Mohammad Amin
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2019, 42 (04) : 913 - 919
  • [24] Monte Carlo dosimetric characterization of the Flexisource Co-60 high-dose-rate brachytherapy source using PENELOPE
    Almansa, Julio F.
    Guerrero, Rafael
    Torres, Javier
    Lallena, Antonio M.
    BRACHYTHERAPY, 2017, 16 (05) : 1073 - 1080
  • [25] Dosimetric characterization of the 60Co BEBIG Co0.A86 high dose rate brachytherapy source using PENELOPE
    Guerrero, Rafael
    Almansa, Julio F.
    Torres, Javier
    Lallena, Antonio M.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2014, 30 (08): : 960 - 967
  • [26] Measurement and calculation of heterogeneity correction factors for an Ir-192 high dose-rate brachytherapy source behind tungsten alloy and steel shields
    Kirov, AS
    Williamson, JF
    Meigooni, AS
    Zhu, Y
    MEDICAL PHYSICS, 1996, 23 (06) : 911 - 919
  • [27] Dedicated high dose rate 192Ir brachytherapy radiation fields for in vitro cell exposures at variable source-target cell distances: killing of mammalian cells depends on temporal dose rate fluctuation
    Veigel, Cornelia
    Hartmann, Guenther H.
    Fritz, Peter
    Debus, Juergen
    Weber, Klaus-Josef
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (04) : 1613 - 1631